PubMed Health⌕ Search

Biomedical subjects

Y Rozenman

Publications and source records attributed to Y Rozenman.

At least 19 recordsLinked to original sources

Acute myocardial infarction caused by coronary embolism complicated by left ventricular free wall rupture.

Acute myocardial infarction with normal coronary arteries is a relatively infrequent finding. This report describes a rare combination of an embolic event to a normal coronary artery, presumably originating from a left atrial thrombus. An anomalous origin of the infarct-related coronary artery presumably enabled preferential penetration of the clot into the artery. The infarction was further complicated by rupture of the left ventricular free wall.

Aged↗

Unusual form of cardiac rupture: sealed subacute left ventricular free wall rupture, evolving to intramyocardial dissecting hematoma and to pseudoaneurysm formation--a case report and review of the literature.

This report describes an unusual course of rupture of the left ventricular free wall, complicating acute myocardial infarction. Spontaneous sealing of the rupture site enabled close echocardiographic follow-up, during which we monitored the development of intramyocardial dissecting hematoma and, finally, development of a full tear in the left ventricular free wall, leading to the formation of a pseudoaneurysm. The pathophysiology, management, and diagnostic criteria of these processes are being revised.

Adult↗

Visual hallucinations in giant cell arteritis: association with visual loss.

OBJECTIVE: To evaluate the frequency and characteristics of visual hallucinations (VH) in patients with giant cell arteritis (GCA) and to determine their relationship to other visual phenomena. METHODS: This prospective study included 31 consecutive patients with GCA. All were asked whether they had experienced recent visual phenomena. Patients with visual symptoms underwent a comprehensive ophthalmologic examination. When unusual visual phenomena were reported, patients were asked to describe their nature, duration, and frequency of occurrence. RESULTS: Visual symptoms occurred in 6 patients: permanent visual loss in 5 and amaurosis fugax in one. In 4 of the 5 patients with permanent visual loss, it was preceded by intermittent VH over a period of 1-10 days. Patients were aware of the unreal nature of the visions. Hallucinations disappeared within 2 weeks, but in one patient, recurred 6 months later in association with further visual deterioration. CONCLUSION: The occurrence of visual hallucinations in patients with GCA-associated visual loss is more common than previously appreciated. As hallucinations preceded permanent loss of vision, this phenomenon may serve as a harbinger of imminent visual loss.

Age Distribution↗

[Non-penetrating deep sclerectomy without collagen implant for glaucoma, as single or combined surgery].

Deep sclerectomy (DS) can be used in glaucoma with increased intraocular pressure when medical treatment fails. It involves removing part of the ocular drainage apparatus. Resistance to intraocular fluid drainage is decreased, improving drainage and decreasing intraocular pressure. By avoiding anterior chamber penetration, DS diminishes frequency of the complications of filtering surgery. 24 eyes of 23 patients underwent DS for primary or secondary open angle glaucoma with elevated intraocular pressure not controlled medically. It included preparation of a 4.0 x 4.0 mm limbal-based external scleral flap, dissecting and removing most of an internal scleral flap (leaving it 1 mm smaller than the external flap), unroofing Schlemm's canal and removing fine endothelial tissue lining its inner walls. The external scleral flap was then repositioned and sutured. Collagen implants were not used. In some cases DS was combined with extracapsular cataract extraction and intraocular lens implantation. Mean intraocular pressure decreased from 24.8 +/- 3.9 mmHg initially to 12.8 +/- 4.4 mmHg 6 months after operation (p < 0.0001). There was no difference in postoperative intraocular pressure between DS as a single procedure or as part of a combined operation. Complications were mild and of short duration. If long-term follow-up shows that lowered intraocular pressures are maintained, DS should be a surgical option in earlier stages of glaucoma.

Cataract Extraction↗

Acute myocardial infarction--a late complication of intracoronary stent placement.

BACKGROUND: Myocardial infarction (MI) as the first indication of postangioplasty restenosis is extremely rare, and it has been speculated that the fibroproliferative restenotic lesion is less likely to undergo plaque rupture than the lipid-laden native atherosclerotic lesion. HYPOTHESIS: The present study was designed to examine whether intracoronary stent implantation affects this course. METHODS: In all, 994 consecutive patients who underwent angioplasty and intracoronary stent implantation in our hospital were reviewed retrospectively for the occurrence of MI. RESULTS: Eight patients (0.8%), all male and hypertensive, aged 33-83 years, presented with an MI due to stent occlusion more than 30 days following stenting (range: 35-398 days). In two patients, MI occurred 3 and 5 h, respectively, following completion of a maximal high-level exercise test that was negative for ischemia. Angiography revealed complete occlusion or significant stenosis of the stent in all eight patients, with an obvious intimal dissection in either edge of the stent in six patients. Except for gender and hypertension, no correlation was found with other risk factors, vessel involved, initial angiographic results, or with stent design, diameter, or length. CONCLUSIONS: Myocardial infarction as a late complication of successful stent implantation occurred in 0.8% of our patients. This is only the lower bound of the estimated frequency for such an event. We hypothesize that the transition point between the relatively fixed stent and the normal artery is exposed to high deformation stress which makes it vulnerable to rupture and dissection. Strenuous exercise and hypertension may increase the deformation stress and the risk of intimal rupture.

Adult↗

Restenosis and progression of coronary disease after balloon angioplasty in patients with diabetes mellitus.

BACKGROUND: Patients with diabetes mellitus (D) (both insulin-requiring D [IRD] and non-IRD) who undergo angioplasty have worse long-term outcome than do non-D patients. Few data are available in the literature that explain these findings. HYPOTHESIS: The study was undertaken to compare restenosis and progression of coronary disease after angioplasty in IRD patients, in non-IRD patients, and in non-D patients. METHODS: Diabetic patients who underwent coronary angioplasty were separated into two subgroups: IRD and non-IRD patients. Their angiographic outcome was compared with non-D patients. We examined retrospectively 353 coronary angiograms of patients who were referred for diagnostic angiography > 1 month after successful angioplasty. Quantitative angiography was used to determine the outcome in dilated narrowings (restenosis) and in nondilated narrowings (disease progression). RESULTS: Baseline clinical and angiographic characteristics were similar in all groups. Restenosis rate was higher in IRD (61%) than in non-IRD (36%) and non-D (35%) patients (p = 0.04). Late luminal loss after angioplasty was two times greater in IRD patients than in the other two groups (p = 0.01). Disease progression of nondilated narrowings was significantly more prominent in non-IRD than in non-D patients: Diameter stenoses were similar in the initial angiogram, but narrowings were significantly more severe (p = 0.02) in the final angiogram (70 +/- 27% and 60 +/- 33%, respectively). New narrowings were more common in non-IRD than in non-D patients: there was a 23% increase in the number of narrowings in the follow-up angiogram in non-IRD patients compared with only 12% in non-D patients (p < 0.003). These new narrowings were more common (p = 0.01) in angioplasty arteries (57 narrowings on 420 arteries--13.6%) than in nonangioplasty arteries (54 narrowings on 639 arteries--8.5%). CONCLUSION: Restenosis is more common in IRD patients and explains the high rate of adverse cardiac events within the first year after coronary intervention in these patients (mainly target lesion revascularization). Disease progression (including new narrowings) is the main determinant of patient outcome > 1 year after coronary intervention and is accelerated in non-IRD compared with non-D patients.

Aged↗

Stents in total occlusion for restenosis prevention. The multicentre randomized STOP study. The Israeli Working Group for Interventional Cardiology.

AIMS: This multicentre randomized study set out to evaluate whether coronary stenting improves the results of successful balloon angioplasty for chronic total occlusion. Balloon angioplasty for chronic total occlusion has a high restenosis rate. Several reports have suggested that coronary stenting may decrease the likelihood of restenosis and reocclusion. METHODS AND RESULTS: Patients with total coronary artery occlusions who had an optimal PTCA result were randomized either to no further treatment or additional stent implantation. The AVE microstent was used and all patients were scheduled for a 1-, 3-, and 6-month clinical follow-up. Repeat coronary angiography to assess the rate and pattern of restenosis was performed at 6 months or earlier if clinically indicated. Ninety-six patients were enrolled in this study. The mean age was 59. 3+/-10.3 years and 15 were females. Forty-eight patients were randomized to the stent arm, receiving 52 stents (lengths 18-39 mm). Stent implantation was successful in all and there were no major procedure-related complications. Sixty-nine patients (72%) were restudied after 6 months. The binary restenosis rates (50%), in the PTCA arm were 70.9% with a minimal lumen diameter of 1.01+/-0.79 mm compared to 42.1% in the stent arm with a minimal lumen diameter of 1.63+/-1.02 mm (P=0.034). Reocclusion occurred in 7.9% in the stent group compared to 16.1% in the PTCA group. Restenosis in the PTCA group was focal in 88% of patients and occurred at the point of total obstruction (within 5 mm), compared to diffuse instent restenosis, which occurred in 54% of the patients in the stent group. CONCLUSION: Coronary stenting can significantly decrease the rate of restenosis and reocclusion of total occlusions. As restenosis in the stent group was more diffuse, care should be taken to implant short stents at the site of occlusion.

Angioplasty, Balloon, Coronary↗

SPECT attenuation artifacts in normal and overweight persons: insights from a retrospective comparison of Rb-82 positron emission tomography and TI-201 SPECT myocardial perfusion imaging.

PURPOSE: Myocardial perfusion imaging can be performed using SPECT or positron emission tomography (PET). SPECT has lower specificity than PET, largely as a result of attenuation artifacts; however, it is more widely available. The authors describe a study of the effect of sex and body weight on the incidence of SPECT attenuation artifacts using a retrospective comparison of TI-201 SPECT and Rb PET. METHODS: One hundred sixty-one persons (101 men, 60 women; 81 normal weight, 80 overweight) underwent TI-201 SPECT and Rb PET. The incidence of observed perfusion defects was studied in territories of the three major coronary arteries. SPECT and PET results were also compared with those of angiography in a subset of 75 patients. RESULTS: One hundred fourteen defects were reported on Rb PET compared with 176 defects with TI-201 SPECT. Excess TI-201 SPECT defects occurred in male and female, normal-weight and overweight persons. The average specificity was 64% for TI-201 SPECT and 84% for Rb PET, reflecting this difference. CONCLUSIONS: Attenuation artifacts in TI-201 SPECT occur frequently and are not confined to easily identifiable subgroups of patients. Therefore, measures to improve specificity of SPECT (e.g., prone or gated imaging) or alternative imaging techniques such as PET have potential advantages for everyone, not simply for obese patients and women with large breasts. In addition, awareness of the prevalence of SPECT attenuation artifacts, in both sexes and all weight categories, may contribute to improved accuracy of interpretation.

Artifacts↗

Treatment of conjunctival intraepithelial neoplasia with topical drops of mitomycin C.

PURPOSE: To evaluate the efficacy and risks of complications of topical mitomycin C (MMC) for small-size conjunctival intraepithelial neoplasia (CIN). METHODS: Eight patients with clinically diagnosed CIN <8 mm were included in the study. Patients received topical drops of MMC, 0.02-0.04%, 4 times daily for 14 days. Retreatment was done when lesions were not eliminated or recurred after the first treatment. RESULTS: Three patients remained disease free after one course of MMC application. Retreatment was done in four patients because of lesions that decreased in size but were not eliminated, and for regrowth in one case. After retreatment, the lesions were eradicated in four patients, whereas in one patient, the treatment failed, and the lesion was surgically excised. The complications of MMC use included mild conjunctival hyperemia in two patients and mild allergy in one patient, which resolved after discontinuation of the treatment. CONCLUSION: Application of topical MMC is an effective treatment for most but not all cases of small-size CIN.

Adult↗

Long-term outcome of patients with very long stents for treatment of diffuse coronary disease.

OBJECTIVES: The study sought to determine the 6-month clinical outcome of patients who underwent implantation of very long coronary stents to treat diffuse disease and/or long dissections and to compare the findings with those reported in the literature for patients who underwent implantation of multiple short coronary stents. BACKGROUND: New designs of flexible stents enable the implantation of long stents rather than multiple short, older design stents. The initial experience is very promising but the long-term outcome has not been described yet. METHODS: Fifty-seven consecutive patients in whom 67 long stents (>/=30 mm) were successfully deployed were included in this study. Six-month clinical and angiographic follow-up was prospectively collected. Patients with recurrent angina underwent coronary angiography without further testing. Patients who remained asymptomatic at the 6-month follow-up visit underwent positron emission tomographic imaging, and those with results suggestive of ischemia underwent coronary angiography. A combined study end point was defined as death, myocardial infarction, and the need for target vessel revascularization. RESULTS: Only 1 patient (2%) reached a study end point at hospital discharge. An additional 20 patients (total 21 patients [37%]) reached an end point by 6 months. The outcome was not influenced by the clinical presentation (stable or unstable angina) or by the indication for stenting (elective or emergency). Predictors for adverse outcome were multiple stents per narrowing (63% vs 29%, P <. 04), and stents smaller than 3.5 mm (49% vs 22%). Narrowing and stent length were not predictive of a study end point in narrowings that were successfully treated by a single long stent. CONCLUSIONS: Elective stenting provides an effective solution for patients with diffuse coronary disease provided that a single long stent (usually <40 mm) can cover the full length of the narrowing. The results are better when vessels larger than 3 mm are treated. Compared with multiple short stents, implantation of a single long stent is probably at least as effective, and the procedure is quicker and cheaper and thus should be the preferred approach.

Aged↗

The Cutting Balloon--a new technology?

The Cutting Balloon consists of a standard balloon dilatation catheter with four microtome-sharp blades that incise the plaque and minimize arterial wall trauma. It was used in 31 patients; nine had calcified arteries, ten had non-compliant lesions, three had in-stent restenosis and nine had aorto-ostial lesions. Seventeen lesions were predilated, 28 were post-dilated and 18 required stent implantation. The procedure was very effective in aorto-ostial lesions, non-compliant lesions that were not responsive to high-pressure balloon dilatation, and was partially successful in calcified arteries. It has a very specific niche in selected lesions.

Journal Article↗

Initial and long-term results with the CrossFlex stent--data from a national registry.

The Cordis CrossFlex trade mark stent is a balloon expandable helical coil made of stainless steel. OBJECTIVE: To assess the short- and long-term safety and efficacy of this stent by conducting a multi-center national registry. METHODS: One hundred and sixteen stents were implanted in 109 patients (mean age 59 3 10 years, 95 males). The lesions were classified as type B2 or C in 56 patients (51%). Successful deployment was achieved in 103 patients (94.5%). Failure was due to damage to the stent (two patients) or inability to reach the lesion (four patients). High-pressure deployment (>14 atm) was used in 68% of cases. RESULTS: Edge dissections occurred in nine patients after high-pressure deployment and necessitated implantation of a second stent. One patient with a large acute myocardial infarction died during hospitalization. Side branch occlusion occurred in five patients (4.6%). Subacute thrombosis occurred in two patients (1.8%) during the first four weeks. During a six-month follow-up period, 18 patients (16.5%) were rehospitalized with recurrent angina. Fifteen patients had coronary angiography and 13 (12.1%) needed additional target lesion revascularization (TLR). Twelve patients required a second PTCA for in-stent restenosis, and one needed a coronary artery bypass graft operation. CONCLUSIONS: The CrossFlex coronary stent can successfully be used in complex coronary lesions, with few short-term complications and a low TLR rate. Operators should be aware of the possibility of edge dissection during high-pressure implantation.

Journal Article↗

Right ventricular myocardial bridge in a patient with pulmonary hypertension--a case report.

Myocardial bridge is a not uncommon finding in routine diagnostic coronary angiography or pathological examination of the heart. It is almost always confined to the left ventricle and the left anterior descending coronary artery. This report describes a patient with chronic lung disease, severe left ventricular dysfunction, and pulmonary hypertension in whom coronary angiography revealed bridging of the right ventricular branch of the right coronary artery.

Aged↗

Prevention of congestive heart failure by early, prehospital thrombolysis in acute myocardial infarction: a long-term follow-up study.

The long term impact of pre-hospital thrombolysis in acute myocardial infarction on the subsequent development of heart failure symptoms was investigated in 362 consecutive patients. The pre hospital strategy, used in 61 patients, allowed for very early administration of streptokinase, within 1.2+/-0.6 (mean+/-S.D.) hours from pain onset. In contrast, 294 patients treated in hospital received lytic treatment within 2.0+/-0.9 hours. The pre hospital group showed faster reperfusion, as measured by the time to peak creatine kinase and to ST segment recovery, but only a slightly better ventricular function, as compared to hospital treated patients. Heart failure symptoms were significantly reduced in the pre hospital group during hospitalization and at long term follow up: there were less dyspnea, fatigue, orthopnea, nocturnal dyspnea, nocturia, peripheral edema and episodes of pulmonary edema. Angina was reduced as well. We conclude that the initial benefit of prehospital thrombolysis translates into long term reduction of heart failure symptoms, thus improving quality of life.

Female↗

[Percutaneous revascularization of the left main coronary artery as coronary artery bypass in high surgical risks].

Coronary artery bypass grafting is the treatment of choice for obstructive disease of the left main coronary artery. Its proximal location and easy accessibility make the left main artery an inviting target for percutaneous intervention, an approach contraindicated by the high associated risk. We describe 2 patients at high operative risk in whom the obstructed main coronary artery was successfully revascularized percutaneously. Coronary stenting and rotational ablation of calcified arteries are essential for successful outcome and minimize complications.

Aged↗

New indicator for stent covering area.

A small gap between stent struts is essential to support the vessel wall, prevent elastic recoil, and prevent intimal flaps from prolpasing into the lumen. We defined Gap Index as the ratio of strut width divided by the percent of the vessel wall area covered by the stent metal, and proved mathematically that this index relates inversely to the total length of stent struts (or coil), and directly related to stent cell size. Twenty-four (12 tubular and 12 coil) stents from 17 manufacturers were analyzed. Strut width in the tubular and coil groups was 354.1 +/- 276.0 and 955.9 +/- 553.9 microm, respectively (P < 0.001). The relative metallic surface area (RMS) in the tubular and coil groups for 3 mm stent diameter was 16.0 +/- 4.6 and 10.6 +/- 3.7%, respectively (P < 0.005). Great variations in Gap Index were found amongst different stents, with up to 100-fold. Gap Index in the tubular and coil groups for 3 mm stent diameter was 24.4 +/- 21.7 and 105.8 +/- 97.5 units, respectively (P = 0.001). Thus, coil stents have a smaller relative metallic surface area despite increased strut width. This is the result of reduced total strut length and fewer and larger cells, as represented by a higher Gap Index. This information may be useful for new stents designs.

Biocompatible Materials↗

Reconstruction of the sternum and chest wall with methyl methacrylate: CT and MRI appearance.

The aim of our study was to define the appearance of methyl methacrylate grafts replacing resected sternum and ribs on CT and MRI and how the sternal graft may mimic an abnormally sclerotic sternum on CT images. We reviewed the CT scans of nine patients who had undergone chest wall resection (eight with malignant and one with benign disease) and reconstruction with a composite of methyl methacrylate and Marlex mesh graft. One of them had an MRI study as well. The size, shape and CT attenuation were assessed on mediastinal and bone window settings. The sternal graft was seen on mediastinal and even better on bone windows as an abnormally wide, irregularly shaped structure, somewhat denser than the normal sternum. The chest wall prosthesis replacing resected ribs was seen as a continuous dense structure and of similar attenuation as that of the sternal graft. On MRI the prosthesis appeared as a well-defined structure with no signal. Reconstruction of the chest wall with methyl methacrylate appears on CT as a diffusely dense sclerotic bone lesion not unlike a malignant lesion. The possibility of a graft has to be included in the differential diagnosis in these cases.

Adolescent↗

Right atrial thrombi are related to indwelling central venous catheter position: insights into time course and possible mechanism of formation.

We studied the effect of central line catheters on thrombus formation in the right atrium (RA), including the incidence and echocardiographic characteristics of the catheter-associated thrombus as well as possible clinical implications in patients. We prospectively studied 55 patients by transesophageal echocardiography within 1 week after Hickman catheter implantation and on a follow-up study at 6 to 8 weeks. We succeeded in imaging the catheter tip in 48 of the 55 patients (87%). In the baseline study 13 had the tip placed in the RA, eight at the superior vena cava-atrium junction, and 27 in the superior vena cava. An abnormal mass, consistent with a thrombus, was found in 12.5% of the patients, all of which were seen within the 13-patient (46%) group with the Hickman catheter tip placed in the RA. Hickman catheter insertion is associated with high incidence (12.5%) of early formation of RA thrombus. The formation of these thrombi is asymptomatic and highly associated (p < 0.001) with the catheter tip position in the RA, in contrast to their positioning in the superior vena cava or in its junction with the right atrium. On the basis of these findings, we recommend that special attention and effort be given to placing of the catheter tip in the superior vena cava and avoiding the RA during the implantation procedure.

Adult↗