PubMed Health⌕ Search

Biomedical subjects

Y Rozenman

Publications and source records attributed to Y Rozenman.

At least 37 records · Page 2Linked to original sources

Quantitative videodensitometric technique for verification of optimal coronary stent implantation.

Coronary angiography is not sensitive enough to define the results of stent implantation. Intravascular ultrasound defines accurately the anatomy of the vessel and the stent within the vessel and is thus considered the gold standard for defining the results of stent implantation. However intravascular ultrasound is an additional invasive procedure that is time consuming and expensive. This study describes a new simple quantitative videodensitometric technique, developed specifically to assess the results of stent implantation and compares the findings to intravascular ultrasound. In the proposed algorithm for the videodensitometric analysis, density profiles were constructed perpendicular to the long axis of the stented segment and each one was compared (after background subtraction) with a theoretic profile of a normal artery at that location. Density deficit index was determined at each point from the actual and theoretic profiles and a global volumetric density deficit index was calculated for each stent by integrating the deficit indices at all points along the stent. Similarly an area stenosis was determined at each point along the stent (using the stent and normal vessel cross sectional areas as defined by intravascular ultrasound) and the global volumetric stent stenosis was calculated by integrating the values of area stenosis along the stent. Twenty-five patients were evaluated immediately before and after coronary stent implantation. Global density deficit index improved from 66.1+/-16.4% before (after last balloon inflation) to 44.4+/-11.1% after stenting (P < 0.001). The shape of the curves of densitometric deficit indices along each stent were similar to the equivalent area stenosis curves as determined by intravascular ultrasound. The correlation (R = 0.74) between the global volumetric density deficit index and the global volumetric stent stenosis is statistically significant (P < 0.001). In conclusion, in this preliminary report we describe a new algorithm for videodensitometric analysis of the results of coronary stent implantation. As compared with intravascular ultrasound this method does not require an additional invasive procedure and it is quick cheap and easy to carry out.

Algorithms↗

Diffuse narrowing of coronary arteries in diabetic patients: the earliest phase of coronary artery disease.

Coronary arteries in diabetic patients appear to be narrower than in normal subjects, but this has not been examined systematically. To investigate this hypothesis we reviewed the data of 711 consecutive patients with angiographically 'normal coronary arteries'. Excluded were patients with valvular, myocardial or pericardial disease, and patients with hypertension or hyperlipidemia. Thirteen diabetic patients (10 men) and 22 nondiabetic persons (8 men) constituted the study and control groups, respectively. The diameters of the coronary arteries and their branches were measured and adjusted for body surface area. The sum of the proximal left anterior descending (LAD), circumflex and right coronary arteries (RCA) was calculated and defined as total coronary diameter (TCD). The sum of the distal LAD, first diagonal, first marginal and distal RCA was calculated and defined as total distal coronary diameter (dTCD). The clinical data of both groups were comparable. Adjusted TCD for body surface area was 5.4 +/- 1.1 and 6.5 +/- 1.1 mm/m2 (p < 0.05) in diabetics and nondiabetics, respectively, and adjusted dTCD was 4.9 +/- 1.2 and 6.1 +/- 1.2 mm/m2 (p = 0.01) in diabetics and normal subjects, respectively. Specific arteries and branches that were significantly smaller in diabetics included: left main coronary artery, distal LAD, first diagonal, proximal RCA, distal RCA, right ventricular branch, and posterolateral and posterior descending artery of RCA origin. Gender was not a confounding factor since the control group had a larger proportion of women and still larger arteries than the diabetic group. In conclusion, coronary arteries and their branches in diabetic patients have smaller diameters than normal subjects. This may be due to increased coronary tone, diffuse mild atherosclerosis or both.

Coronary Angiography↗

Coronary arteriovenous malformations in a patient with hereditary hemorrhagic telangiectasia--a case report.

Hereditary hemorrhagic telangiectasia (Osler-Weber-Rendu) disease is characterized by cutaneous, mucosal, and visceral vascular anomalies. Two patients were previously described with coronary artery aneurysms (ectasia) associated with this disease. This report describes a patient with Osler-Weber-Rendu disease in whom multiple coronary arteriovenous malformations were identified during coronary angiography. The patient presented with anginal chest pain resulting from severe anemia. Upper gastrointestinal endoscopy revealed multiple angiodysplastic lesions throughout the esophagus and stomach.

Anemia, Iron-Deficiency↗

The diameter of the epicardial coronary arteries in patients with dilated cardiomyopathy.

We investigated the diameter of epicardial coronary arteries in 12 patients (ten men) with dilated cardiomyopathy, and compared to 21 normal persons (14 men). Dilated cardiomyopathy patients were younger than controls with no difference in height, weight and body surface area. Ejection fraction was lower in dilated cardiomyopathy compared to normals (31+/-10% and 73+/-7%, respectively, P<0.001). Left ventricular mass was significantly larger (P=0.04). The sum of diameters of the proximal left anterior descending, circumflex and right coronary arteries (Total Coronary Diameter) in the dilated cardiomyopathy and controls was 13.4+/-2.7 and 10.5+/-1.5 mm (P<0.001). Absolute diameters of the left main, left anterior descending, circumflex, proximal right coronary artery and the right ventricular branch in dilated cardiomyopathy were also significantly larger as was Total Coronary Diameter adjusted for body surface area. Total Coronary Diameter adjusted for left ventricular mass, was significantly smaller (103.42+/-30.38, 146.00+/-41.59 mm/mg, respectively, P<0.03). Specific arteries in the dilated cardiomyopathy adjusted for left ventricular mass were significantly smaller, or had a tendency for smaller diameter compared to normals. There was no correlation between age and coronary diameter in each group. After adjusting for left ventricular mass there was no difference in coronary artery diameter between men and women. Thus, coronary arteries of patients with dilated cardiomyopathy have increased absolute diameter compared to normals, but decreased diameter when adjusted for left ventricular mass. This may contribute to patients' complaints and to the natural history of the disease.

Adult↗

Long-term angiographic follow-up of coronary balloon angioplasty in patients with diabetes mellitus: a clue to the explanation of the results of the BARI study. Balloon Angioplasty Revascularization Investigation.

OBJECTIVES: We sought to compare the angiographic outcome of diabetic patients (treated with insulin or oral hypoglycemic agents) after successful coronary angioplasty with that in nondiabetic patients. The analysis included the outcome of the dilated (restenosis) and nondilated narrowings (disease progression). BACKGROUND: Recent data have confirmed that diabetes mellitus is an important risk factor for long-term adverse events. These adverse events are more common after balloon angioplasty than after bypass surgery (Bypass Angioplasty Revascularization Investigation [BARI]). METHODS: We examined retrospectively 353 coronary angiograms of 248 patients (55 diabetic, 193 nondiabetic) who were referred for diagnostic angiography >1 month after successful angioplasty (1.4 +/- 0.6 [mean +/- SD] repeat angiograms/patient). Restenosis and disease progression/regression were compared between groups by means of quantitative angiography. RESULTS: Baseline clinical and angiographic characteristics were similar in both groups. There was a nonsignificant trend for a higher restenosis rate of dilated narrowings in diabetic patients. There were no significant changes between diabetic and nondiabetic patients in the rates of progression and regression of narrowings that were not dilated during the initial angioplasty. The main difference was in the rate of appearance of new narrowings: There was a 22% increase in the number of narrowings on the follow-up angiogram in diabetic patients (38 new, 174 preexisting narrowings) compared with 12% (86 new, 734 preexisting narrowings) in nondiabetic patients (p < 0.004). Diabetes mellitus and the performance of angioplasty in the artery had an additive risk for development of new narrowings, which were identified in 15 (16.9%) of 89 arteries with and 16 (13.2%) of 121 without angioplasty in diabetic patients and in 42 (12.7%) of 331 arteries with and 38 (7.3%) of 518 without angioplasty in nondiabetic patients (p = 0.009). CONCLUSIONS: The combination of diabetes mellitus and an artery that was instrumented during balloon angioplasty is additive and increases the risk of formation of new narrowing in that artery. This finding may explain the high adverse event rates observed in diabetic patients in the angioplasty arm of the BARI study, most of whom had angioplasty performed in at least two arteries.

Aged↗

Coronary angiographic characteristics of patients with permanent artificial pacemakers.

BACKGROUND: The cause of severe cardiac conduction disturbances is often uncertain. The aim of this study was to examine a group of patients with permanent pacemakers who underwent coronary arteriography to determine the extent of coronary atherosclerotic disease that might be responsible for the conduction disturbances. METHODS AND RESULTS: Forty-three consecutive patients with a permanent pacemaker and 36 matched control patients were investigated. The coronary angiographic study included measurement of diameter and stenosis severity, qualitative assessment of flow, and classification of pathological anatomy, particularly the blood supply to territories supplying the different segments of the conduction system. Among 43 patients with a permanent pacemaker, 27 had ischemic heart disease (17 after coronary artery bypass graft surgery). The conduction disturbance was infranodal in 28 patients, sinus nodal in 6, AV nodal in 4, and complete AV block of unspecified origin in 5. Patients with permanent pacemakers had a coronary artery pathology compromising blood flow to the septal branches and the right coronary artery (type IV anatomy). This pattern was significantly different from the matched control patients, in whom the most prevalent coronary anatomy was the combination of right coronary artery with distal left anterior descending artery (not involving the septal branches) lesions (P=.007). CONCLUSIONS: Patients with coronary artery disease and severe conduction disturbances that require implantation of permanent pacemakers are more likely to have a specific pathological coronary anatomy that combines a compromised blood flow to the septal branches of the left anterior descending artery with right coronary artery lesions. The location of lesions in the coronary tree rather than severe diffuse atherosclerosis appears to be responsible for the conduction disturbances.

Aged↗

Changing paradigms in thrombolysis in acute myocardial infarction.

Acute myocardial infarction occurs when a ruptured coronary artery plaque causes sudden thrombotic occlusion of a coronary artery and cessation of coronary artery blood flow. This paper reviews the underlying coronary pathology in progressive coronary atherosclerosis, mechanisms of plaque rupture and arterial occlusion and the time relationship between coronary occlusion and myocardial necrosis. Reperfusion can be achieved by chemical thrombolysis with different thrombolytic agents. Early lysis is achieved best by prehospital administration, a transtelephonic monitor, a mobile intensive care unit, active general practitioner treatment or by warning the emergency room of impending arrival of a patient. Thrombolytic therapy may be unsuccessful and not achieve Grade III TIMI flow in less than 4 h (or even 2 h) due to inadequate or intermittent perfusion or reocclusion. Adjuvant therapy includes aspirin and platelet receptor antagonists. Bleeding is a constant danger. Direct percutaneous transluminal coronary angioplasty (PTCA) may be as effective or better than chemical thrombolysis. Reperfusion protects the myocardium and salvages viable tissue. It also improves mechanical remodelling of the ventricle. Long-term follow-up has shown that quantum leaps of fresh coronary occlusion causes step-wise progression in patient disability and that further early, prompt reperfusion can salvage myocardium and prevent this inexorable progress of the disease.

Fibrinolytic Agents↗

Atherosclerosis studies by intracoronary ultrasound.

Intravascular ultrasound (IVUS) is a new technique of tomographic visualization of the coronary arteries: its lumen, wall and pathology. Three dimensional (3D) reconstruction shows the tubular structure of the arterial wall and its pathology. IVUS has many advantages over coronary angiography: it has better resolution and shows many hidden lesions. IVUS has helped uncover the underlying mechanisms of percutaneous transluminal coronary angioplasty (PTCA), restenosis, the use and value of other interventional techniques such as directional coronary atherectomy (DCA), rotational atherectomy and stent implantation, and has great value in planning complex interventional procedures. The new American Heart Association (AHA) classification of coronary atherosclerosis pathology can be demonstrated by IVUS. IVUS is sensitive for studies of atheroma regression and progression and shows the coronary artery lesions after cardiac transplantation.

Animals↗

Initial experience with long coronary stents: the changing practice of coronary angioplasty.

The initial experience with the use of long coronary stents (> 30 mm in length) was analyzed retrospectively. Sixty-seven stents were deployed in 58 narrowings in 57 patients (34 AVE Microstents, 16 Nir stents, four Gianturco-Roubin II stents, and 13 Wallstents). Stents were implanted in 22 patients with unstable angina, 34 patients with stable angina, and one patient during direct angioplasty for acute myocardial infarction. Eighteen additional short stents were implanted to cover the entire length of the lesions so that an average of one and a half stents were deployed per patient. The length of the narrowings before stenting was 40 +/- 20 mm and the length of the stented segments was 45 +/- 20 mm. Stents were deployed for "bailout" in 23 narrowings, to improve suboptimal results of balloon angioplasty in 18 narrowings, and electively in 17 narrowings. Twenty of the 67 long stents were deployed in saphenous vein grafts. The success rate of stent implantation was 100%. One patient had a rupture of a saphenous vein graft after deployment of two long stents, with tamponade treated by emergency surgery. One patient had chest pain 18 hours after stent deployment; by the time he arrived at the catheterization laboratory the pain had subsided and the angiogram revealed a patent artery with normal flow. There were no other major complications during the hospital course and 1-month follow-up. We conclude that long coronary stents can be deployed successfully in native coronary arteries and vein grafts. They are useful for elective implantation and extremely helpful in bailout situations. The immediate results are excellent, but long-term outcome is awaited.

Aged↗

Angiographic deterioration of target coronary artery narrowing as a result of percutaneous balloon angioplasty.

We evaluated the long-term angiographic outcome of balloon angioplasty by comparing original and follow-up target coronary narrowing. Rather than using restenosis to determine outcome, as in most angioplasty studies, we took an unusual approach and analyzed outcome in terms that are commonly used in progression and regression studies after medical interventions. Quantitative angiographic measurements were undertaken in 315 narrowings with an initial diameter stenosis <90% before and after angioplasty and at follow-up. Angiographic deterioration (>10% increase in follow-up diameter stenosis) was identified in 44 (14%) narrowings. Angiographic deterioration was not influenced by age, sex, risk factors, lipid profile, or the indication for angioplasty. Deterioration was also not predicted by the severity, length, or the location of the narrowing. The deteriorating narrowings had a higher recoil after dilatation compared with narrowings with angiographic improvement (21% +/- 31% vs 12% +/- 17%, p = 0.006); the residual stenosis after angioplasty was therefore higher. The late loss was also significantly increased compared with narrowings with angiographic improvement (65% +/- 26% vs 8% +/- 24%, p < 0.001). We conclude that the incidence of angiographic deterioration of coronary disease as a result of restenosis is uncommon but not negligible. Interventional cardiologists should resist the temptation to dilate mild, silent coronary narrowings because the procedure might have an unfavorable angiographic (and probably clinical) effect.

Angioplasty, Balloon, Coronary↗

Mitomycin C treatment for conjunctival-corneal intraepithelial neoplasia: a multicenter experience.

OBJECTIVE: The purpose of the study is to evaluate the efficacy and risks of topical mitomycin C (MMC) for conjunctival-corneal intraepithelial neoplasia (CCIN). DESIGN: The study design was a clinical case series of CCIN. PARTICIPANTS: Seventeen patients, 16 with biopsy-confirmed CCIN and 1 with invasive squamous cell carcinoma (SCC), were included in the study. INTERVENTION: Patients received topical drops of MMC 0.02% to 0.04% four times daily from 7 to 28 days. Retreatment was done in cases of lesion recurrence. MAIN OUTCOME MEASURES: The size of the CCIN before and after the treatment and ocular complications post-MMC application were evaluated. RESULTS: Ten patients remained disease-free after one course of MMC application. In one case, residual CCIN remained very small without regrowth. In the one patient with invasive SCC and in five patients with CCIN, regrowth occurred within 6 months of the first treatment. After retreatment, invasive SCC and CCIN in an additional two patients were eradicated. In two cases, although the size of the lesions decreased after two and three applications of MMC, regrowth occurred, and the CCIN returned to its original size. In the final case, limited recurrence has occurred and no retreatment has been done. The complications of MMC use included mild-to-moderate conjunctival hyperemia and mild allergy, which resolved after discontinuation of the treatment. Severe pain manifested when treatment was longer than 14 days. CONCLUSIONS: Application of topical MMC is an efficient treatment for most but not all cases of CCIN.

Administration, Topical↗

Quantitative in vivo retinal thickness measurements in healthy subjects.

PURPOSE: The early detection of visual threatening retinal thickness alterations is important for the purpose of offering affected patients proven treatment when indicated. Currently, the clinical methods that are available for obtaining an impression of retinal thickness are subjective and require experience and expertise. The authors present measurements of foveal thickness in healthy individuals obtained by a newly developed instrument that enables a noninvasive, noncontact, safe, and fast measurement of the retinal thickness anywhere in the posterior pole. METHODS: A prototype of the retinal thickness analyzer (RTA) that operates on the principle of laser-slit biomicroscopy was used. Retinal thickness was measured in healthy emmetropic volunteers. RESULTS: Fifty eyes were measured. The average thickness at the foveola was 178 +/- 44 microm (+/- standard deviation; range, 100-322 microm). CONCLUSION: The retinal thickness measured by the RTA in healthy subjects correspond well to previous published data (in vivo and histologic) on retinal thickness. This instrument may prove valuable in detecting retinal thickness alteration in macular diseases.

Adolescent↗

Exudative age-related macular degeneration in patients with diabetic retinopathy and its relation to retinal laser photocoagulation.

PURPOSE: To study the relationship between exudative age-related macular degeneration and diabetic retinopathy and assess the influence of retinal laser photocoagulation for diabetic retinopathy on the occurrence of exudative age-related macular degeneration. METHODS: Two groups, one of diabetic retinopathy patients treated with laser and the other of non-laser-treated diabetic retinopathy patients, were studied by means of fundoscopy and fluorescein angiography for the presence of exudative age-related macular degeneration. RESULTS: Exudative age-related macular degeneration was not observed in 431 patients treated with laser photocoagulation, and was diagnosed in 3.3% of 151 non-laser-treated patients. CONCLUSION: Patients treated by laser photocoagulation for diabetic retinopathy are less prone to develop the exudative form of age-related macular degeneration.

Age Distribution↗

The Radial Artery: An Applicable Approach to Complex Coronary Angioplasty.

The purpose of this study was to assess the clinical value of the transradial approach (TRA) in coronary angioplasty. During the 18Ðmonth period from June 1994 to December 1995, 250 patients (mean age 61 +/- 11) underwent coronary angioplasty using the transradial approach. In 7 (2.8%) radial puncture was unsuccessful and in 6 (2.4%) additional femoral access was needed to complete the procedure. Ninety patients (36%) had angioplasty of two or three vessels and 49.5% had type B2 or C lesions. Sixty-five patients (22%) had additional procedures: stent implantations in 50 (16%) and rotational ablation in 15 (6%). Angiographic success was 97% and there were no deaths. Major procedural complications included: Q-wave myocardial infarction in 2 (0.8%), non-Q-wave myocardial infarction in 5 (2.0%), urgent coronary artery bypass grafting in 2 (0.8%) and CVA in 2 (0.8%). Local vascular complication included: compartment syndrome necessitating fasciotomy in 1 patient (0.4%), mild hematoma in 6 (2.4%) and a small pseudo-aneurysm treated by local compression in 4 (1.6%). Radial pulse was palpated in 93% before discharge and in 3% adequate flow could be heard with Doppler. No patient suffered from ischemia of the hand. Complex coronary angioplasty can be performed safely using the TRA with few vascular complications.

Journal Article↗