PubMed Health⌕ Search

Biomedical subjects

Yingjie Liu

Publications and source records attributed to Yingjie Liu.

12 recordsLinked to original sources

Stimulation of arachidonic acid release by vasopressin in A7r5 vascular smooth muscle cells mediated by Ca2+-stimulated phospholipase A2.

Arachidonic acid (AA) regulates many aspects of vascular smooth muscle behaviour, but the mechanisms linking receptors to AA release are unclear. In A7r5 vascular smooth muscle cells pre-labelled with (3)H-AA, vasopressin caused a concentration-dependent stimulation of 3H-AA release that required phospholipase C and an increase in cytosolic [Ca2+]. Ca2+ release from intracellular stores and Ca2+ entry via L-type channels or the capacitative Ca2+ entry pathway were each effective to varying degrees. Selective inhibitors of PLA2 inhibited the 3H-AA release evoked by vasopressin, though not the underlying Ca2+ signals, and established that cPLA2 mediates the release of AA. We conclude that in A7r5 cells vasopressin stimulates AA release via a Ca2+-dependent activation of cPLA2.

Animals↗

Construction of an artificial heart pump performance test system.

A hydraulic loop, which simulates pressure/flow response of the human circulatory system, is needed to bench test the various versions of rotary left ventricular assist devices (LVADs). This article describes the design of such a loop and the simulated response of different physiological states, such as a healthy person in sleep, rest, and mild physical activity, and in different pathological states. The loop consists of: (1) pulsatile left and right cardiac simulators; (2) air/water tanks to model the venous and arterial compliances; (3) tygon tubes to model the venous, arterial, and other system flow resistances; and (4) a tuning clamp to model the variation in system resistance characteristics under different cardiac pressure/flow conditions. The simulated responses were compared to the data found in the literature to validate the loop performance prior to LVAD testing.

Biomimetic Materials↗

Different phospholipase-C-coupled receptors differentially regulate capacitative and non-capacitative Ca2+ entry in A7r5 cells.

Several receptors, including those for AVP (Arg8-vasopressin) and 5-HT (5-hydroxytryptamine), share an ability to stimulate PLC (phospholipase C) and so production of IP3 (inositol 1,4,5-trisphosphate) and DAG (diacylglycerol) in A7r5 vascular smooth muscle cells. Our previous analysis of the effects of AVP on Ca2+ entry [Moneer, Dyer and Taylor (2003) Biochem. J. 370, 439-448] showed that arachidonic acid released from DAG stimulated NO synthase. NO then stimulated an NCCE (non-capacitative Ca2+ entry) pathway, and, via cGMP and protein kinase G, it inhibited CCE (capacitative Ca2+ entry). This reciprocal regulation ensured that, in the presence of AVP, all Ca2+ entry occurred via NCCE to be followed by a transient activation of CCE only when AVP was removed [Moneer and Taylor (2002) Biochem. J. 362, 13-21]. We confirm that, in the presence of AVP, all Ca2+ entry occurs via NCCE, but 5-HT, despite activating PLC and evoking release of Ca2+ from intracellular stores, stimulates Ca2+ entry only via CCE. We conclude that two PLC-coupled receptors differentially regulate CCE and NCCE. We also address evidence that, in some A7r5 cells lines, AVP fails either to stimulate NCCE or inhibit CCE [Brueggemann, Markun, Barakat, Chen and Byron (2005) Biochem. J. 388, 237-244]. Quantitative PCR analysis suggests that these cells predominantly express TRPC1 (transient receptor potential canonical 1), whereas cells in which AVP reciprocally regulates CCE and NCCE express a greater variety of TRPC subtypes (TRPC1=6>2>3).

Animals↗

Stacking due to ionic transport number mismatch during sample sweeping on microchips.

Sample stacking can occur in isoconductive buffer systems as a result of ion transport mismatches that cause changes in buffer conductivity during electrophoresis. Fluorescence imaging was used to examine this effect in the sweeping of hydrophobic dyes with sodium dodecyl sulfate (SDS) on microchips. Imaging revealed the occurrence of a stacking effect in a sodium borate buffer system in which the sample buffer and SDS-containing run buffer had the same initial conductivity. Injected sample plugs were first swept by SDS micelles and the swept band was then stacked at the trailing end of the sample zone. This effect is due to changes in conductivity at both the front and back interfaces of the injected sample plug and can be modeled by moving boundary equations. Maximum signal enhancements of 86-, 160- and 560-fold were obtained for Rhodamine 560, Rhodamine B and Rhodamine 6G, respectively, by the combination of sweeping and stacking within a 1 cm section of microchannel. Based on sample sweeping/stacking and manipulation of the electric field polarity, a method of trapping and concentrating analyte from multiple injections was also demonstrated.

Buffers↗

Long lasting inhibition of adenylyl cyclase selectively mediated by inositol 1,4,5-trisphosphate-evoked calcium release.

In A7r5 smooth muscle cells, vasopressin stimulates release of Ca2+ from intracellular stores and Ca2+ entry, and it inhibits adenylyl cyclase (AC) activity. Inhibition of AC is prevented by inhibition of phospholipase C or when the increase in cytosolic [Ca2+] is prevented by the Ca2+ buffer, BAPTA. It is unaffected by pertussis toxin, inhibition of protein kinase C, or L-type Ca2+ channels or by removal of extracellular Ca2+. The independence of extracellular Ca2+ occurs despite inhibition of AC by vasopressin persisting for at least 15 min, whereas the cytosolic [Ca2+] returns to its basal level within 1-2 min in Ca2+-free medium. Although capacitative Ca2+ entry (CCE), activated by emptying stores with thapsigargin, inhibits AC, Ca2+ entry via CCE or L-type Ca2+ channels activated by vasopressin is ineffective. Temporally separating vasopressin-evoked Ca2+ release from the assessment of AC activity revealed that the transient Ca2+ signal resulting from Ca2+ mobilization causes a long lasting inhibition of AC. By contrast, inhibition of AC by thapsigargin-evoked CCE reverses rapidly after removal of extracellular Ca2+. Inhibition of AC by vasopressin is prevented by inhibition of Ca2+-calmodulin-dependent protein kinase II. We conclude that persistent inhibition of AC (probably AC-3) by vasopressin is mediated by inositol trisphosphate-evoked Ca2+ release causing activation of Ca2+-calmodulin-dependent protein kinase II. Our results establish that an important interaction between two ubiquitous signaling pathways is tuned selectively to Ca2+ release via inositol trisphosphate receptors and that the interaction transduces a transient Ca2+ signal into a long lasting inhibition of AC.

Adenylyl Cyclase Inhibitors↗

Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing.

A mock circulatory loop, which simulates the human circulatory system, is needed to bench test the various versions of continuous flow (CF) left ventricular assist devices (LVADs). This article describes the design and initial testing of such a loop. The loop consists of: (1) pulsatile left and right cardiac simulators; (2) air/water tanks to model the venous and arterial compliances; (3) tygon tubes to model the venous, arterial, and other system flow resistances; and (4) a tuning clamp to model the variation in system resistance characteristics under different cardiac pressure/flow conditions. Several loop measurements were carried out without an LVAD to verify the cardiovascular modeling of a healthy person in sleep, rest, and physical activity, and in different pathological states, and compared to the data found in the literature to validate the loop performance prior to LVAD testing.

Blood Circulation↗

A bridge from short-term to long-term left ventricular assist device--experimental verification of a physiological controller.

A physiological controller is a key component to optimize the performance of left ventricular assist devices (LVADs) from short term to long term (10-20 years). The difficulties of its design lie in the inaccurate modeling of any particular human cardiovascular system because of limited knowledge, the large fluctuation of systemic parameters in normal daily life, nonlinearity introduced by one-way heart valves, and restriction on available sensors. The desired physiological controller for a permanent LVAD is expected to handle different activity levels such as sleeping, resting and exercising, and different pathological levels of left ventricular failure. In this study, a physiological controller designed for a long-term continuous flow (CF) LVAD was tested in a mock circulatory loop. The pressure head across the LVAD and motor signals were used as feedback signals, which were obtained from long-term reliable sensors. Three activities and five different pathological levels of left ventricular failure were simulated to test the performance of the designed controller. The experimental results showed that the designed controller restored the total peripheral flow and arterial pressure, and decreased the left ventricular end-diastolic pressure to a safe range. The suction of the left ventricle was successfully reversed by the designed controller. The controller thus was proven to be able to control the LVAD properly in many of the possible physiological conditions experienced by LVAD recipients in long term.

Biomedical Engineering↗

DNA probe attachment on plastic surfaces and microfluidic hybridization array channel devices with sample oscillation.

DNA probe immobilization on plastic surfaces and device assembly are both critical to the fabrication of microfluidic hybridization array channel (MHAC) devices. Three oligonucleotide (oligo) probe immobilization procedures were investigated for attaching oligo probes on four different types of plastic surfaces (polystyrene, polycarbonate, poly(methylmethacrylate), and polypropylene). These procedures are the Surmodics procedure, the cetyltrimethylammonium bromide (CTAB) procedure, and the Reacti-Bind procedure. To determine the optimal plastic substrate and attachment chemistry for array fabrication, we investigated plastic hydrophobicity, intrinsic fluorescence, and oligo attachment efficiency. The Reacti-Bind procedure is least effective for attaching oligo probes in the microarray format. The CTAB procedure performs well enough to use in array fabrication, and the concentration of CTAB has a significant effect on oligo immobilization efficiency. We also found that use of amine-modified oligo probes resulted in better immobilization efficiency than use of unmodified oligos with the CTAB procedure. The oligo probe immobilization on plastic surfaces by the Surmodics procedure is the most effective with regard to probe spot quality and hybridization sensitivity. A DNA hybridization assay on such a device results in a limit of detection of 12pM. Utilizing a CO(2) IR laser machining and adhesive layer approach, we have developed an improved procedure for realizing a DNA microarray inside a microfluidic channel. This device fabrication procedure allows for more feasible spot placement in the channel and reduced sample adsorption by adhesive tapes used in the fabrication procedure. We also demonstrated improved hybridization kinetics and increased detection sensitivity in MHAC devices by implementing sample oscillation inside the channel. A limit of detection of 5pM has been achieved in MHAC devices with sample oscillation.

Carbocyanines↗

Plastic biochannel hybridization devices: a new concept for microfluidic DNA arrays.

Conventional DNA hybridization assay kinetics depends solely on the diffusion of target to surface-bound probes, causing long hybridization times. In this study, we examined the possibilities of accelerating the hybridization process by using microfluidic channels ("biochannels") made of polycarbonate, optionally with an integrated pump. We produced two different devices to study these effects: first, hybridization kinetics was investigated by using an eSensor electrochemical DNA detection platform allowing kinetic measurements in homogenous solution. We fabricated an integrated cartridge for the chip comprising the channel network and a micropump for the oscillation of the hybridization mixture to further overcome diffusion limitations. As a model assay, we used an assay for the detection of single-nucleotide polymorphisms in the HFE-H gene. Second, based on the biochannel approach, we constructed a plastic microfluidic chip with a network of channels for optical detection of fluorescent-labeled targets. An assay for the simultaneous detection of four pathogenic bacteria surrogate strains from multiple samples was developed for this device. We observed high initial hybridization velocities and a fast attainment of equilibrium for the biochannel with integrated pump. Experimental results were compared with predictions generated by computer simulations.

Computer Simulation↗

High sensitivity PCR assay in plastic micro reactors.

Small volume operation and rapid thermal cycling have been subjects of numerous reports in micro reactor chip development. Sensitivity aspects of the micro PCR reactor have not been studied in detail, however, despite the fact that detection of rare targets or trace genomic material from clinical and/or environmental samples has been a great challenge for microfluidic devices. In this study, a serpentine shaped thin (0.75 mm) polycarbonate plastic PCR micro reactor was designed, constructed, and tested for not only its rapid operation and efficiency, but also its detection sensitivity and specificity, in amplification of Escherichia coli (E. coli) K12-specific gene fragment. At a template concentration as low as 10 E. coli cells (equivalent to 50 fg genomic DNA), a K12-specific gene product (221 bp) was adequately amplified with a total of 30 cycles in 30 min. Sensitivity of the PCR micro reactor was demonstrated with its ability to amplify K12-specific gene from 10 cells in the presence of 2% blood. Specificity of the polycarbonate PCR micro reactor was also proven through multiplex PCR and/or amplification of different pathogen-specific genes. This is, to our knowledge, the first systematic study of assay sensitivity and specificity performed in plastic, disposable micro PCR devices.

Base Sequence↗

DNA amplification and hybridization assays in integrated plastic monolithic devices.

PCR amplification, DNA hybridization, and a hybridization wash have been integrated in a disposable monolithic DNA device, containing all of the necessary fluidic channels and reservoirs. These integrated devices were fabricated in polycarbonate plastic material by CO2 laser machining and were assembled using a combination of thermal bonding and adhesive tape bonding. Pluronics polymer phase change valves were implemented in the devices to fulfill the valving requirements. Pluronics polymer material is PCR compatible, and 30% Pluronics polymer valves provide enough holding pressure to ensure a successful PCR amplification. By reducing the temperature locally, to approximately 5 degrees C, Pluronics valves were liquefied and easily opened. A hybridization channel was made functional by oligonucleotide deposition, using Motorola proprietary surface attachment chemistry. Reagent transport on the device was provided by syringe pumps, which were docked onto the device. Peltier thermal electrical devices powered the heating and cooling functionality of the device. Asymmetrical PCR amplification and subsequent hybridization detection of both Escherichia coli K-12 MG1655 and Enterococcus faecalis DNAE genes have been successfully demonstrated in these disposable monolithic devices.

DNA↗

Advections with significantly reduced dissipation and diffusion.

Back and Forth Error Compensation and Correction (BFECC) was recently developed for interface computation using a level set method. We show that BFECC can be applied to reduce dissipation and diffusion encountered in a variety of advection steps, such as velocity, smoke density, and image advections on uniform and adaptive grids and on a triangulated surface. BFECC can be implemented trivially as a small modification of the first-order upwind or semi-Lagrangian integration of advection equations. It provides second-order accuracy in both space and time. When applied to level set evolution, BFECC reduces volume loss significantly. We demonstrate the benefits of this approach on image advection and on the simulation of smoke, bubbles in water, and the highly dynamic interaction between water, a solid, and air. We also apply BFECC to dye advection to visualize vector fields.

Algorithms↗