DNA probe attachment on plastic surfaces and microfluidic hybridization array channel devices with sample oscillation.

Abstract

DNA probe immobilization on plastic surfaces and device assembly are both critical to the fabrication of microfluidic hybridization array channel (MHAC) devices. Three oligonucleotide (oligo) probe immobilization procedures were investigated for attaching oligo probes on four different types of plastic surfaces (polystyrene, polycarbonate, poly(methylmethacrylate), and polypropylene). These procedures are the Surmodics procedure, the cetyltrimethylammonium bromide (CTAB) procedure, and the Reacti-Bind procedure. To determine the optimal plastic substrate and attachment chemistry for array fabrication, we investigated plastic hydrophobicity, intrinsic fluorescence, and oligo attachment efficiency. The Reacti-Bind procedure is least effective for attaching oligo probes in the microarray format. The CTAB procedure performs well enough to use in array fabrication, and the concentration of CTAB has a significant effect on oligo immobilization efficiency. We also found that use of amine-modified oligo probes resulted in better immobilization efficiency than use of unmodified oligos with the CTAB procedure. The oligo probe immobilization on plastic surfaces by the Surmodics procedure is the most effective with regard to probe spot quality and hybridization sensitivity. A DNA hybridization assay on such a device results in a limit of detection of 12pM. Utilizing a CO(2) IR laser machining and adhesive layer approach, we have developed an improved procedure for realizing a DNA microarray inside a microfluidic channel. This device fabrication procedure allows for more feasible spot placement in the channel and reduced sample adsorption by adhesive tapes used in the fabrication procedure. We also demonstrated improved hybridization kinetics and increased detection sensitivity in MHAC devices by implementing sample oscillation inside the channel. A limit of detection of 5pM has been achieved in MHAC devices with sample oscillation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yingjie Liu, Cory B Rauch. 2003-06-01. DNA probe attachment on plastic surfaces and microfluidic hybridization array channel devices with sample oscillation.. https://doi.org/10.1016/s0003-2697(03)00051-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Real-time quantification of RNA polymerase activity using a "broken beacon".

A novel assay using a hybridization-based method was developed for real-time monitoring of RNA synthesis. In this work, a "broken beacon" in which the fluor and quencher were located on separate but complementary oligonucleotides was used to quantify the amount of RNA production by T7 polymerase. The relative lengths of the fluor-oligo and quencher-oligo, and their relative concentrations were optimized. The experimentally determined limit-of-detection was approximately 45 nM. The new assay was compared to the "gold-standard" radiolabel ([(32)P]NTP incorporation) assay for RNA quantification. While the broken beacon assay exhibited a higher limit of detection, it provided an accurate measure of RNA production rates. However, the broken beacon assay provided the significant analytical advantages of (i) a real-time and continuous measurement, (ii) no requirement for the use of radiolabels or gel-based analysis, and (iii) substantial time and labor savings.

Carbocyanines↗

Characterization of DNA hybridization on partially aminated diamond by aromatic compounds.

Here, we report a novel method of micropatterning oligonucleotides via aromatic groups as linkers on partially amino-terminated diamond and the inherence on subsequent hybridization. The covalent immobilization of probe oligonucleotides and characterization of immobilized probe oligonucleotides with carboxylic compounds were investigated by X-ray photoelectron spectroscopy (XPS). To confirm the effects of linker flexibility in a low amino group on diamond for probe oligonucleotides, three kinds of dicarboxylic compound--adipic acid, terephthalic acid, and trimesic acid--were used for immobilization of probe oligonucleotides, like linkers; and these oligonucleotides were hybridized with target oligonucleotides labeled with Cy 5 on the micropatterned diamond surface. The hybridization intensities determined by epifluorescence microscopy were compared and analyzed.

Carbocyanines↗