PubMed Health⌕ Search

Biomedical subjects

Z Gryczynski

Publications and source records attributed to Z Gryczynski.

At least 19 recordsLinked to original sources

Functionally different agonists induce distinct conformations in the G protein coupling domain of the beta 2 adrenergic receptor.

G protein-coupled receptors represent the largest class of drug discovery targets. Drugs that activate G protein-coupled receptors are classified as either agonists or partial agonists. To study the mechanism whereby these different classes of activating ligands modulate receptor function, we directly monitored ligand-induced conformational changes in the G protein-coupling domain of the beta(2) adrenergic receptor. Fluorescence lifetime analysis of a reporter fluorophore covalently attached to this domain revealed that, in the absence of ligands, this domain oscillates around a single detectable conformation. Binding to an antagonist does not change this conformation but does reduce the flexibility of the domain. However, when the beta(2) adrenergic receptor is bound to a full agonist, the G protein coupling domain exists in two distinct conformations. Moreover, the conformations induced by a full agonist can be distinguished from those induced by partial agonists. These results provide new insight into the structural consequence of antagonist binding and the basis of agonism and partial agonism.

Adrenergic beta-Agonists↗

A FRET-based sensor reveals large ATP hydrolysis-induced conformational changes and three distinct states of the molecular motor myosin.

The molecular motor myosin is proposed to bind to actin and swing its light-chain binding region through a large angle to produce an approximately 10 nm step in motion coupled to changes in the nucleotide state at the active site. To date, however, direct dynamic measurements have largely failed to show changes of that magnitude. Here, we use a cysteine engineering approach to create a high resolution, FRET-based sensor that reports a large, approximately 70 degree nucleotide-dependent angle change of the light-chain binding region. The combination of steady-state and time-resolved fluorescence resonance energy transfer measurements unexpectedly reveals two distinct prestroke states. The measurements also show that bound Mg.ADP.Pi, and not bound Mg.ATP, induces the myosin to adopt the prestroke states.

Adenosine Diphosphate↗

A thermophilic apoglucose dehydrogenase as nonconsuming glucose sensor.

Blood glucose is a clinically important analytes for diabetic health care. In this preliminary report we describe a protein biosensor for d-glucose based on a thermostable glucose dehydrogenase. The glucose dehydrogenase was noncovalently labeled with 8-anilino-1-naphthalene sulfonic acid (ANS). The ANS-labeled enzyme displayed an approximate 25% decrease in emission intensity upon binding glucose. This decrease can be used to measure the glucose concentration. Our results suggest that enzymes which use glucose as their substrate can be used as reversible and nonconsuming glucose sensors in the absence of required cofactors. Moreover, the possibility of using inactive apoenzymes for a reversible sensor greatly expands the range of proteins which can be used as sensors, not only for glucose, but for a wide variety of biochemically relevant analytes.

Animals↗

A protein biosensor for lactate.

Blood lactate is a clinically valuable diagnostic indicator. In this preliminary report we describe a protein biosensor for L-lactate based on beef heart lactate dehydrogenase (LDH). LDH was noncovalently labeled with 8-anilino-1-naphthalene sulfonic acid (ANS). The ANS-labeled LDH displayed an approximately 40% decrease in emission intensity upon binding lactate. This decrease can be used to measure the lactate concentration. The ANS-labeled LDH was further utilized in a new sensing format, polarization sensing, which is suitable for miniaturization to a point-of-care lactate monitor. However, temporal instability of beef heart LDH indicates the need for further protein engineering prior to development of a more robust lactate-sensing protein.

Anilino Naphthalenesulfonates↗

Calcium-induced flexibility changes in the troponin C-troponin I complex.

The contraction of vertebrate striated muscle is modulated by Ca(2+) binding to the regulatory protein troponin C (TnC). Ca(2+) binding causes conformational changes in TnC which alter its interaction with the inhibitory protein troponin I (TnI), initiating the regulatory process. We have used the frequency domain method of fluorescence resonance energy transfer (FRET) to measure distances and distance distributions between specific sites in the TnC-TnI complex in the presence and absence of Ca(2+) or Mg(2+). Using sequences based on rabbit skeletal muscle proteins, we prepared functional, binary complexes of wild-type TnC and a TnI mutant which contains no Cys residues and a single Trp residue at position 106 within the TnI inhibitory region. We used TnI Trp-106 as the FRET donor, and we introduced energy acceptor groups into TnC by labeling at Met-25 with dansyl aziridine or at Cys-98 with N-(iodoacetyl)-N'-(1-sulfo-5-naphthyl)ethylenediamine. Our distance distribution measurements indicate that the TnC-TnI complex is relatively rigid in the absence of Ca(2+), but becomes much more flexible when Ca(2+) binds to regulatory sites in TnC. This increased flexibility may be propagated to the whole thin filament, helping to release the inhibition of actomyosin ATPase activity and allowing the muscle to contract. This is the first report of distance distributions between TnC and TnI in their binary complex.

Animals↗

Time-resolved spectral observations of cadmium-enriched cadmium sulfide nanoparticles and the effects of DNA oligomer binding.

We measured the steady-state and time-resolved fluorescence spectral properties of cadmium-enriched nanoparticles (CdS-Cd2+). These particles displayed two emission maxima, at 460 and 580 nm. The emission spectra were independent of excitation wavelength. Surprisingly, the intensity decays were strongly dependent on the observation wavelength, with longer decay times being observed at longer wavelengths. The mean lifetime increased from 150 to 370 ns as the emission wavelength was increased from 460 to 650 nm. The wavelength-dependent lifetimes were used to construct the time-resolved emission spectra, which showed a growth of the long-wavelength emission at longer times, and decay-associated spectra, which showed the longer wavelength emission associated with the longer decay time. These nanoparticles displayed anisotropy values as high as 0.35, depending on the excitation and emission wavelengths. Such high anisotropies are unexpected for presumably spherical nanoparticles. The anisotropy decayed with two correlation times near 5 and 370 ns, with the larger value probably due to overall rotational diffusion of the nanoparticles. Addition of a 32-base pair oligomer selectively quenched the 460-nm emission, with less quenching being observed at longer wavelengths. The time-resolved intensity decays were minimally affected by the DNA, suggesting a static quenching mechanism. The wavelength-selected quenching shown by the nanoparticles may make them useful for DNA analysis.

Biopolymers↗

Conformation of microtubule-bound paclitaxel determined by fluorescence spectroscopy and REDOR NMR.

The conformation of microtubule-bound paclitaxel has been examined by fluorescence and solid-state NMR spectroscopy. A fluorescent derivative of paclitaxel, 3'-N-debenzoyl-3'-N-(m-aminobenzoyl)paclitaxel (N-AB-PT), was prepared by semisynthesis. No differences in the microtubule-promoting activity between N-AB-PT and paclitaxel were observed, demonstrating that addition of the amino group did not adversely affect the ligand-receptor association. The distance between the fluorophore N-AB-PT and the colchicine binding site on tubulin polymers was determined through time-resolved measurements of fluorescence resonance energy transfer to be 29 +/- 2 A. The absorption and emission spectra of N-AB-PT bound to microtubules and in various solvents were measured. A plot of the Stokes shift as a function of solvent polarity was highly unusual. The Stokes shift increased linearly with solvent polarity in protic solvents, which is expected due to the nature of the fluorophore. In aprotic solvents, however, the Stokes shift was invariant with solvent polarity, indicating that the fluorophore was somehow shielded from the effects of the solvent. These data are best explained by considering the solution-state conformational properties of paclitaxel. It is known that paclitaxel adopts different conformations depending on the nature of the solvent, and these fluorescence data are consistent with the molecule adopting a "hydrophobic collapsed" conformation in protic solvents and an "extended" conformation in aprotic solvents. The Stokes shift of microtubule-bound N-AB-PT was within the protic solvent region, demonstrating that microtubule-bound paclitaxel is in a hydrophobic collapsed conformation. Microtubule-bound paclitaxel was also investigated by solid-state NMR. Paclitaxel was labeled with (19)F at the para position of the C-2 benzoyl substituent and with (13)C and (15)N in the side chain. Distances between the fluorine and carbon nuclei were determined by REDOR. The distance between the fluorine and the 3'-amide carbonyl carbon was 9.8 +/- 0.5 A, and the distance between the fluorine atom and the 3'-methine carbon was 10. 3 +/- 0.5 A. These spectroscopic data were used in conjunction with molecular modeling to refine the microtubule-bound conformation of paclitaxel and to suggest an alternative orientation of the ligand within the paclitaxel binding site.

Animals↗

Inhibitory region of troponin I: Ca(2+)-dependent structural and environmental changes in the troponin-tropomyosin complex and in reconstituted thin filaments.

In muscle thin filaments, the inhibitory region (residues 96-117) of troponin I (TnI) is thought to interact with troponin C (TnC) in the presence of Ca(2+) and with actin in the absence of Ca(2+). To better understand these interactions, we prepared mutant TnIs which contained a single Cys-96 or Cys-117 and labeled them with the thiol-specific fluorescent probe N-(iodoacetyl)-N'-(1-sulfo-5-naphthyl)ethylenediamine (IAEDANS). We characterized the microenvironments of the AEDANS labels on TnI in the presence and absence of Ca(2+) by measuring the extent of acrylamide quenching of fluorescence and lifetime-resolved anisotropy. In the troponin-tropomyosin (Tn-Tm) complex, the AEDANS labels on both Cys-96 and Cys-117 were less accessible to solvent and less flexible in the presence of Ca(2+), reflecting closer interactions with TnC under these conditions. In reconstituted thin filaments, the environment of the AEDANS on Cys-96 was not greatly affected by Ca(2+), while the AEDANS on Cys-117 was more accessible but significantly less flexible as it moved away from actin and interacted strongly with TnC in the presence of Ca(2+). We used fluorescence resonance energy transfer (FRET) to measure distances between AEDANS on TnI Cys-96 or Cys-117 and 4-¿[(dimethylamino)phenyl]azo¿phenyl-4'-maleimide (DABmal) on actin Cys-374 in reconstituted thin filaments. In the absence of Ca(2+), the mean distances were 40.2 A for Cys-96 and 35.2 A for Cys-117. In the presence of Ca(2+), Cys-96 moved away from actin Cys-374 by approximately 3.6 A, while Cys-117 moved away by approximately 8 A. This suggests the existence of a flexible "hinge" region near the middle of TnI, allowing amino acid residues in the N-terminal half of TnI to interact with TnC in a Ca(2+)-independent manner, while the C-terminal half of TnI binds to actin in the absence of Ca(2+) or to TnC in the presence of Ca(2+). This is the first report to demonstrate structural movement of the inhibitory region of TnI in the thin filament.

Acrylamide↗

Background suppression in frequency-domain fluorometry.

Gated detection is often used in time-domain measurements of long-lived fluorophores for suppression of interfering short-lived autofluorescence. However, no direct method has been available for gated detection and background suppression when using frequency-domain fluorometry. We describe a direct method for real-time suppression of autofluorescence in frequency-domain fluorometry. The method uses a gated detector and the sample is excited by a pulsed train. The detector is gated on following each excitation pulse after a suitable time delay for decay of the prompt autofluorescence. Under the same experimental conditions a detectable reference signal is obtained by using a long lifetime standard with a known decay time. Because the sample and reference signals are measured under identical excitation, gating and instrumental conditions, the data can be analyzed as usual for frequency-domain data without further processing. We show by simulations that this method can be used to resolve single and multiexponential decays in the presence of short lifetime autofluorescence.

Fluorescence↗

Green fluorescent protein as a probe of rotational mobility within bacteriophage T4.

Green fluorescent protein (GFP) was targeted into bacteriophage T4 heads and proheads as a probe of the internal environment. Targeting was accomplished with internal protein III (IPIII) fusion proteins or capsid targeting sequence (CTS)-tagged proteins, where CTS is the 10-amino acid residue CTS of IPIII. Recombinant phage T4[CTS/IPIII/GFP], T4[CTS/IPIII(T)GFP], and T4[CTS/GFP] packaged GFP fusion proteins and processed them at cleavage sites designated /. Steady-state and time-resolved fluorescence measurements suggest that packaged GFP is concentrated to a high density, that fusion protein IPIII(T)GFP occurs in a tightly clustered arrangement, and that the internal milieu of the phage head reduces rotational mobility of GFP. Phage, but not proheads, packaged with fusion protein IPIII(T)GFP gave an unexpectedly lower anisotropy than phage and proheads packaged with GFP, which suggests IPIII(T)GFP is bound to DNA in a manner that causes close associations between GFP molecules resulting in homotransfer between fluorophores within packaged phage. Targeting of reporter proteins into active virions is a promising approach for determining the structure of the condensed DNA, and properties of encapsidated viral enzymes.

Bacteriophage T4↗

Novel fluorescence sensing methods for high throughput screening.

We describe two new methods of fluorescence sensing for use in high throughput screening (HTS). Modulation sensing transforms analyte-dependent intensity changes into a change in the low-frequency modulation signal. Polarization sensing transforms an intensity change into a change in polarization. Both methods are internally calibrated by using a reference film immediately adjacent to the sample, which can be readily located on the HTS plate or on a nearby optical component and provides an intensity or polarization reference. Modulation sensing and polarization sensing were both shown useful for measurements of fluorophore concentrations, pH, or calcium concentrations in the wells of HTS plates. Sensing with a reference film provides the opportunity to internally reference HTS measurements without the need for additions to the sample. This approach can provide standardization for assays performed at different times.

Fluorescence Polarization↗

The beta-glycosidase from the hyperthermophilic archaeon Sulfolobus solfataricus: enzyme activity and conformational dynamics at temperatures above 100 degrees C.

Enzymes from thermophilic organisms are stable and active at temperatures which rapidly denature mesophilic proteins. However, there is not yet a complete understanding of the structural basis of their thermostability and thermoactivity since for each protein there seems to exist special networks of interactions that make it stable under the desired conditions. Here we have investigated the activity and conformational dynamics above 100 degrees C of the beta-glycosidase isolated from the hyperthermophilic archaeon Sulfolobus solfataricus. This has been made possible using a special stainless steel optical pressure cell which allowed us to perform enzyme assays and fluorescence measurements up to 160 degrees C without boiling the sample. The beta-glycosidase from S. solfataricus showed maximal activity at 125 degrees C. The time-resolved fluorescence studies showed that the intrinsic tryptophanyl fluorescence emission of the protein was represented by a bimodal distribution with Lorential shape and that temperature strongly affected the protein conformational dynamics. Remarkably, the tryptophan emission reveals that the indolic residues remain shielded from the solvent even at 125 degrees C, as shown by shielding from quenching and restricted tryptophan solubility. The relationship between enzyme activity and protein structural dynamics is discussed.

Algorithms↗

Polarization sensing of fluorophores in tissues for drug compliance monitoring.

We used a new method, polarization sensing, to monitor the concentration of the fluorophore rhodamine 800 in an intralipid suspension and in chicken tissue. Rhodamine 800 (Rh800) could be excited at 648 nm using a laser pointer. We developed a simple device for measuring the combined emission from a highly polarized reference film and the unpolarized or orthogonally polarized emission of Rh800 from the scattering intralipid or tissue. The concentration of Rh800 in this medium was revealed by large changes in the polarization (P) with values of P ranging from 0.8 to -0.9. It is possible to vary the sensitive Rh800 concentration range by variation of the detected emission wavelengths, orientation of the excitation polarizer, or fluorophore concentration in the reference film. Polarization sensing of fluorophores in tissue requires only steady-state detection, and can be accomplished with simple and/or portable electronics. Such devices may find use in electronic detection of ingested medicines based on transdermal detection of nontoxic long-wavelength fluorophores.

Animals↗

Polarization sensing with visual detection.

We describe a new approach to fluorescence sensing which relies on visual determination the polarization. The sensing device consists of a fluorescent probe, which changes intensity in responses to the analyte, and an oriented fluorescent film, which is not affected by the analyte. An emission filter is selected to observe the emission from both the film and the sensing fluorophore. Changes in the probe intensity result in changes in the polarization of the combined emission from the sensor and reference. The degree of polarization can be detected visually using a dual polarizer with adjacent sections oriented orthogonally to each other. The emission passing through the dual polarizer is viewed with a second analyzing polarizer. This analyzer is rotated manually to yield equal intensities from both sides of the dual polarizer. This approach was used to measure the concentration of RhB in intralipid and to measure pH using 6-carboxyfluorescein. The analyzer angle is typically accurate to 1 degree, providing pH values accurate to +/- 0.1 pH unit at the midpoint of the titration curve. We also describe a method of visual polarization sensing that does not require an oriented film and that can use the same fluorophore for the sample and reference. These approaches to visual sensing are generic and can be applied to a wide variety of analytes for which fluorescent probes are available. Importantly, the devices are simple, with the only electronic component being the light source.

Algorithms↗

Anisotropy-based sensing with reference fluorophores.

We describe a new approach to fluorescence sensing based on measurements of steady-state anisotropies in the presence of reference fluorophores with known anisotropies. The basic concept is that the anisotropy of a mixture reflects a weighted average of the anisotropies of the emitting species. By use of reference fluorophores the starting anisotropy can be near zero, or near 0.9 for oriented films which contain the reference fluorophore. Changing intensities of the analyte result in changes in anisotropy. A wide dynamic range of anisotropies is available because of the freedom to select high or low starting values. Anisotropy-based sensing was demonstrated for pH using 6-carboxyfluorescein and for protein affinity or immunoassay using an oriented film with high anisotropy and a protein labeled with a metal-ligand complex. The latter measurements were performed with a simple light-emitting diode excitation source without an excitation polarizer. The sensitive range of the assay can be adjusted by changing the intensity of the reference fluorophore. Anisotropy-based sensing can have numerous applications in clinical and analytical chemistry.

Anisotropy↗

Polarization-based oxygen sensor.

A new approach to oxygen sensing based on the luminescence polarization observed from a novel type of sensor is described. The oxygen sensor consists of an oxygen-sensitive silicone film containing tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) chloride [Ru(dpp)3Cl2] and an oxygen-insensitive film of Styryl 7 in poly(vinyl alcohol). Polarizers are used to select orthogonally polarized emission components from Ru(dpp)3Cl2 and Styryl 7. The polarization of the combined emission was found to be highly sensitive to the partial pressure of oxygen. This method of polarization sensing is generic and can be used with any fluorophore which displays an analyte-dependent change in intensity.

Fluorescence Polarization↗

High Throughput Screening with Multiphoton Excitation.

Fluorescence detection is extensively used in high throughput screening. In HTS there is a continuous migration toward higher density plates and smaller sample volumes. In the present report we describe the advantages of two-photon or multiphoton excitation for HTS. Multiphoton excitation (MPE) is the simultaneous absorption of two long-wavelength photons to excite the lowest singlet state of the fluorophore. MPE is typically accomplished with short but high-intensity laser pulses, which allows simultaneous absorption of two or more photons. The intensity of the multiphoton-induced fluorescence is proportional to the square, cube, or higher power of the instantneous photon flux. Consequently, two-photon or multiphoton excitation only occurs at the focal point of the incident beam. This property of two-photon excitation allows the excited volume to be very small and to be localized in the center of each well in the HTS plate. We show that two-photon-induced fluorescence of fluorescein can be reliably measured in microwell plates. We also show the use of 6-carboxy fluorescein as a pH probe with two-photon excitation, and measure 4'-6-diamidino-2-phenylindole (DAPI) binding and two-photon-induced fluorescence. In further studies we measure the time-dependent intensity decays of DAPI bound to DNA and of calcium-dependent fluorophores. Finally, we demonstrate the possibility of three-photon excitation of several fluorophores, including indole, in the HTS plate. These results suggest that MPE can be used in high-density multiwell plates.

Journal Article↗

Fluorescence spectral properties of the anticancer drug topotecan by steady-state and frequency domain fluorometry with one-photon and multi-photon excitation.

Topotecan is an antitumor agent with activity against a variety of cancers. We examined the steady-state and time-resolved fluorescence spectral properties of topotecan with one- and two-photon excitation. Topotecan was found to display a high two-photon cross section near 20 GM for wavelengths within the fundamental output of a Ti:sapphire laser, 800-880 nm. In frozen solution the anisotropies of topotecan are near the theoretical maxima for one-photon and two-photon excitation with colinear electronic transitions. The intensity and anisotropy decays of topotecan fluorescence were found to be homogeneous (single exponentials) in phosphate-buffered saline and propylene glycol. The steady-state and time-resolved data indicate that topotecan binds to a double-helical DNA oligomer d(AT)10 resulting in increased anisotropies and multiexponential intensity and anisotropy decays. Subnanosecond components in the anisotropy decay of the DNA-topotecan complex suggest loose binding of the drug to DNA. Loose binding of topotecan to DNA is also revealed by accessibility of topotecan to collisional quenching by iodide.

Antineoplastic Agents↗