PubMed Health⌕ Search

PubMed · 10610691

Background suppression in frequency-domain fluorometry.

Abstract

Gated detection is often used in time-domain measurements of long-lived fluorophores for suppression of interfering short-lived autofluorescence. However, no direct method has been available for gated detection and background suppression when using frequency-domain fluorometry. We describe a direct method for real-time suppression of autofluorescence in frequency-domain fluorometry. The method uses a gated detector and the sample is excited by a pulsed train. The detector is gated on following each excitation pulse after a suitable time delay for decay of the prompt autofluorescence. Under the same experimental conditions a detectable reference signal is obtained by using a long lifetime standard with a known decay time. Because the sample and reference signals are measured under identical excitation, gating and instrumental conditions, the data can be analyzed as usual for frequency-domain data without further processing. We show by simulations that this method can be used to resolve single and multiexponential decays in the presence of short lifetime autofluorescence.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J R Lakowicz, I Gryczynski, Z Gryczynski, M L Johnson. 2000-01-01. Background suppression in frequency-domain fluorometry.. https://doi.org/10.1006/abio.1999.4346

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lambda/4 resonance of an optical monopole antenna probed by single molecule fluorescence.

We present a resonant optical nanoantenna positioned at the end of a metal-coated glass fiber near-field probe. Antenna resonances, excitation conditions, and field localization are directly probed in the near field by single fluorescent molecules and compared to finite integration technique simulations. It is shown that the antenna is equivalent to its radio frequency analogue, the monopole antenna. For the right antenna length and local excitation conditions, antenna resonances occur that lead to an enhanced localized field near the antenna apex. Direct mapping of this field with single fluorescent molecules reveals a spatial localization of 25 nm, demonstrating the importance of such antennas for nanometer resolution optical microscopy.

Fluorescence↗

An automated fluorescence-based method for continuous assay of PP2A activity.

Protein serine/threonine phosphatase (PP2A) is a major cellular enzyme implicated in the control of numerous signaling processes. The accurate measurement of PP2A activity in crude cell lysates, immune complexes, and purified preparations provides insight into the function and regulation of this essential enzyme, which, in turn, can lead to a better understanding of the signaling pathways that it modulates. The method presented here utilizes 6,8-difluoro-4-methylumbelliferyl phosphate (DiFMUP) and a FLEXstation for the continuous measure of PP2A activity associated with many different protein preparations. This automated fluorescence-based assay offers several distinct advantages over colorimetric and radioactive assays of phosphatase activity including (1) decreased substrate preparation time, (2) real-time kinetic data, (3) high sensitivity, and (4) the capability to analyze a wide variety of phosphatases.

Fluorescence↗