An impedance array biosensor for detection of multiple antibody-antigen interactions.

Electrochemical impedance spectroscopy (EIS) combined with a gold electrode array was developed to detect multiple antibody-antigen interactions. Hepatitis B surface antigen (HBsAg), as a model sample, was employed to evaluate the characteristics of the biosensor. The array was fabricated by immobilizing antibodies on the self-assembled molecules surface of the electrodes. The surface characteristics of the array during the binding process including the antibody-antigen conjugation and the sandwich complex with HRP-labeled antibody, as well as the precipitation layer, were characterized by atomic force microscopy (AFM) and electrochemical impedance spectroscopy, respectively. A linear relationship between electron-transfer resistance and the concentrations of HBsAg ranged from 10 pg ml(-1) to 1 ng ml(-1) and the detection limit of 10 pg ml(-1) was obtained. 100 pg ml(-1) antigen samples, such as rat IgG, HBsAg and HBeAg, as well as the antigen mixture, were incubated with the relative antibody-modified electrodes on the array. No obvious cross-talk reaction was observed. All these results confirm the feasibility of applying electrochemical impedance spectroscopy to the electrode array.

Animals↗

Label-free electrochemical detection for aptamer-based array electrodes.

An electrochemical impedance spectroscopy method of detection for aptamer-based array electrodes is reported in which the binding of aptamers immobilized on gold electrodes leads to impedance changes associated with target protein binding events. Human IgE was used as a model target protein and incubated with the aptamer-based array consisting of single-stranded DNA containing a hairpin loop. To increase the binding efficiency for proteins, a hybrid modified layer containing aptamers and cysteamine was fabricated on the photolithographic gold surface through molecular self-assembly. Atomic force microscopy analysis demonstrated that human IgE could be specifically captured by the aptamer and stand well above the self-assembled monolayer (SAM) surface. Compared to immunosensing methods using anti-human IgE antibody as the recognition element, impedance spectroscopy detection could provide higher sensitivity and better selectivity for aptamer-modified electrodes. The results of this method show good correlation for human IgE in the range of 2.5-100 nM. A detection limit of 0.1 nM (5 fmol in a 50-microL sample) was obtained, and an average of the relative standard deviation was <10%. The method herein describes the first label-free detection for arrayed electrodes utilizing electrochemical impedance spectroscopy.

Aptamers, Nucleotide↗