PubMed Health⌕ Search

PubMed · 16097746

Label-free electrochemical detection for aptamer-based array electrodes.

Abstract

An electrochemical impedance spectroscopy method of detection for aptamer-based array electrodes is reported in which the binding of aptamers immobilized on gold electrodes leads to impedance changes associated with target protein binding events. Human IgE was used as a model target protein and incubated with the aptamer-based array consisting of single-stranded DNA containing a hairpin loop. To increase the binding efficiency for proteins, a hybrid modified layer containing aptamers and cysteamine was fabricated on the photolithographic gold surface through molecular self-assembly. Atomic force microscopy analysis demonstrated that human IgE could be specifically captured by the aptamer and stand well above the self-assembled monolayer (SAM) surface. Compared to immunosensing methods using anti-human IgE antibody as the recognition element, impedance spectroscopy detection could provide higher sensitivity and better selectivity for aptamer-modified electrodes. The results of this method show good correlation for human IgE in the range of 2.5-100 nM. A detection limit of 0.1 nM (5 fmol in a 50-microL sample) was obtained, and an average of the relative standard deviation was <10%. The method herein describes the first label-free detection for arrayed electrodes utilizing electrochemical impedance spectroscopy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Danke Xu, Dawei Xu, Xiaobo Yu, Zhihong Liu, Wei He, Zhenqiu Ma. 2005-08-15. Label-free electrochemical detection for aptamer-based array electrodes.. https://doi.org/10.1021/ac050192m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Label-free protein biosensor based on aptamer-modified carbon nanotube field-effect transistors.

We have fabricated label-free protein biosensors based on aptamer-modified carbon nanotube field-effect transistors (CNT-FETs) for the detection of immunoglobulin E (IgE). After the covalent immobilization of 5'-amino-modified 45-mer aptamers on the CNT channels, the electrical properties of the CNT-FETs were monitored in real time. The introduction of target IgE at various concentrations caused a sharp decrease in the source-drain current, and a gradual saturation was observed at lower concentrations. The amount of the net source-drain current before and after IgE introduction on the aptamer-modified CNT-FETs increased as a function of IgE concentration. The detection limit for IgE was determined as 250 pM. We have also prepared CNT-FET biosensors using a monoclonal antibody against IgE (IgE-mAb). The electrical properties of the aptamer- and antibody-modified CNT-FETs were compared. The performance of aptamer-modified CNT-FETs provided better results than the ones obtained using IgE-mAb-modified CNT-FETs under similar conditions. Thus, we suggest that the aptamer-modified CNT-FETs are promising candidates for the development of label-free protein biosensors.

Aptamers, Nucleotide↗

Affinity capture and detection of immunoglobulin E in human serum using an aptamer-modified surface in matrix-assisted laser desorption/ionization mass spectrometry.

Capture and detection of immunoglobulin E (IgE) in simple solution and in human serum using an aptamer-modified probe surface for affinity matrix-assisted laser desorption/ionization mass spectroscopy detection is reported. Detectable signals were obtained for 1 amol of IgE applied either in a single, 1microL application of 1 pM IgE or after 10 successive, 1-microL applications of 100 fM IgE. In both cases, the surface was rinsed after each application of IgE to remove sample concomitants including salts and free or nonspecifically associated proteins. Detection of native IgE, which is the least abundant of the serum immunoglobulins and occurs at subnanomolar levels, in human serum was demonstrated and interference from the high-abundance immunoglobulins and albumin was investigated. The aptamer-modified surface showed high selectivity toward immunoglobulins in serum, with no significant interference from serum albumin. Addition of IgE to the serum suppressed the signals from the other immunoglobulins, confirming the expected selectivity of the aptamer surface toward IgE. Dilution of the serum increased the selectivity toward IgE; the protein was detected without interference in a 10,000-fold dilution of the serum, which is consistent with detection of IgE at amol (pM) levels in standard solutions.

Aptamers, Nucleotide↗

Aptamer-based electrochemical detection of picomolar platelet-derived growth factor directly in blood serum.

We report an electrochemical, aptamer-based (E-AB) sensor for the detection of platelet-derived growth factor (PDGF) directly in blood serum. The E-AB approach employs alternating current voltammetry to monitor target-induced folding in a methylene blue-modified, PDGF-binding aptamer. The sensor is sensitive, highly selective, and essentially reagentless: we readily detect the BB variant of PDGF at 1 nM directly in undiluted, unmodified blood serum and at 50 pM (1.25 ng/mL) in serum-diluted 2-fold with aqueous buffer. The sensitivity and selectivity achieved by this sensor match or significantly exceed those of the best analogous optical approaches. For example, the detection limit attained in 50% serum is achieved against a >25 million-fold excess of contaminating blood proteins and represents a 4 order of magnitude improvement over the most sensitive optical PDGF aptasensor reported to date. Moreover, the E-AB sensor combines these promising attributes in a platform that is reusable, label-free, and electronic. Given these advantages, E-AB sensors appear well suited for implementation in portable microdevices directed at the direct detection of proteins and small molecules in complex, largely unprocessed clinical samples.

Aptamers, Nucleotide↗