Double-cross hydrostatic pressure sample injection for chip CE: variable sample plug volume and minimum number of electrodes.

A novel sample injection method for chip CE was presented. This injection method uses hydrostatic pressure, generated by emptying the sample waste reservoir, for sample loading and electrokinetic force for dispensing. The injection was performed on a double-cross microchip. One cross, created by the sample and separation channels, is used for formation of a sample plug. Another cross, formed by the sample and controlling channels, is used for plug control. By varying the electric field in the controlling channel, the sample plug volume can be linearly adjusted. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip, without any electrode or external pressure pump, thus allowing a sample injection with a minimum number of electrodes. The potential of this injection method was demonstrated by a four-separation-channel chip CE system. In this system, parallel sample separation can be achieved with only two electrodes, which is otherwise impossible with conventional injection methods. Hydrostatic pressure maintains the sample composition during the sample loading, allowing the injection to be free of injection bias.

Electrodes↗

Grafting epoxy-modified hydrophilic polymers onto poly(dimethylsiloxane) microfluidic chip to resist nonspecific protein adsorption.

In order to achieve a simple covalent hydrophilic polymer coating on poly(dimethylsiloxane) (PDMS) microfluidic chip, epoxy modified hydrophilic polymers were synthesized in aqueous solution with a persulfate radical initiation system, and crosslinked onto PDMS pretreated by oxygen plasma and silanized with 3-aminopropyl-triethoxysilanes (APTES). Glycidyl methacrylate (GMA) was copolymerized with acrylamide (poly(AAM-co-GMA)) or dimethylacrylamide (poly(DAM-co-GMA)), and graft polymerized with polyvinylpyrrolidone (PVP-g-GMA) or polyvinylalcohol (PVA-g-GMA). The epoxy groups in the polymers were determined by UV spectra after derivation with benzylamine. Reflection absorption infrared spectroscopy (RAIRS) confirmed covalent grafting of GMA-modified polymers onto PDMS surface. Electroosmotic flow (EOF) in the polymer grafted microchannel was strongly suppressed within the range pH 3-11. Surface adsorption of lysozyme and bovine serum albumin (BSA) was reduced to less than 10% relative to that on the native PDMS surface. On the GMA-modified polymer coated PDMS microchip, basic proteins, peptides, and sodium dodecyl sulfate (SDS) denatured proteins were separated successfully.

Acrylamides↗

Parallel analysis of biomolecules on a microfabricated capillary array chip.

This paper focused on a self-developed microfluidic array system with microfabricated capillary array electrophoresis (mu-CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda-lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high-voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.

Amino Acids↗

Studying protein-drug interaction by microfluidic chip affinity capillary electrophoresis with indirect laser-induced fluorescence detection.

We developed a microfluidic chip-affinity CE method based on indirect LIF detection to study protein-drug interactions. The interaction between heparin and BSA was quantitatively studied, as a model system. In our method, sodium fluorescein was chosen as background, and redistilled water as marker to monitor EOF. The electrophoretic mobility changes of BSA were measured, with various concentrations of heparin added to the running buffer. Each run was completed within 80 s. The binding constant was determined to be (1.24 +/- 0.05) x 10(3) M(-1), which was in good agreement with that reported in the literature.

Electrophoresis, Microchip↗

Studying drug-plasma protein interactions by two-injector microchip electrophoresis frontal analysis.

We developed a simple, rapid, and sensitive two-injector microchip electrophoresis frontal analysis (MCE-FA) method for studying drug-plasma protein interactions. In this method, large volumes of a reference sample and drug-plasma protein mixture were simultaneously introduced into the respective sections of the microchannel through the separated injectors and then electrophoresed. Since the reference sample did not meet with the interacting species during migration, it could be used as an external standard. The interaction between heparin and HSA was quantitatively characterized as a model system. The binding constant was found to be (1.53 +/- 0.01) x 10(4) M(-1).

Anticoagulants↗

Integrated isotachophoretic preconcentration with zone electrophoresis separation on a quartz microchip for UV detection of flavonoids.

A quartz microchip integrated isotachophoretic (ITP) preconcentration with zone electrophoresis (ZE) separation was fabricated using a novel multi-point pressure method featured in normal temperature and lower pressure during bonding process. ITP followed by subsequential ZE of two flavonoids, quercetin and isorhamnetin on the microchip was performed consecutively on the homemade microfluidic workstation with UV detection, resulting in a decreased detectable concentration of 32-fold, compared to the ZE mode only, and their detection limits decreased down to 0.2 microg/mL and 1.2 microg/mL, respectively.

Electrophoresis, Microchip↗

Mini-electrochemical detector for microchip electrophoresis.

This paper presents the development of a mini-electrochemical detector for microchip electrophoresis. The small size (3.6 x 5.0 cm2, W x L) of the detector is compatible with the dimension of the microchip. The use of universal serial bus (USB) ports facilitates installation and use of the detector, miniaturizes the detector, and makes it ideal for lab-on-a-chip applications. A fixed 10 M ohm feedback resistance was chosen to convert current of the working electrode to voltage with second gain of 1, 2, 4, 8, 16, 32, 64 and 128 for small signal detection instead of adopting selectable feedback resistance. Special attention has been paid to the power support circuitry and printed circuit board (PCB) design in order to obtain good performance in such a miniature size. The working electrode potential could be varied over a range of +/-2.5 V with a resolution of 0.01 mV. The detection current ranges from -0.3 x 10(-7) A to 2.5 x 10(-7) A and the noise is lower than 1 pA. The analytical performance of the new system was demonstrated by the detection of epinephrine using an integrated PDMS/glass microchip with detection limit of 2.1 microM (S/N = 3).

Computers↗

Multilayer poly(vinyl alcohol)-adsorbed coating on poly(dimethylsiloxane) microfluidic chips for biopolymer separation.

A poly(dimethylsiloxane) (PDMS) microfluidic chip surface was modified by multilayer-adsorbed and heat-immobilized poly(vinyl alcohol) (PVA) after oxygen plasma treatment. The reflection absorption infrared spectrum (RAIRS) showed that 88% hydrolyzed PVA adsorbed more strongly than 100% hydrolyzed one on the oxygen plasma-pretreated PDMS surface, and they all had little adsorption on original PDMS surface. Repeating the coating procedure three times was found to produce the most robust and effective coating. PVA coating converted the original PDMS surface from a hydrophobic one into a hydrophilic surface, and suppressed electroosmotic flow (EOF) in the range of pH 3-11. More than 1,000,000 plates/m and baseline resolution were obtained for separation of fluorescently labeled basic proteins (lysozyme, ribonuclease B). Fluorescently labeled acidic proteins (bovine serum albumin, beta-lactoglobulin) and fragments of dsDNA phiX174 RF/HaeIII were also separated satisfactorily in the three-layer 88% PVA-coated PDMS microchip. Good separation of basic proteins was obtained for about 70 consecutive runs.

DNA↗

On-line isotachophoretic preconcentration and gel electrophoretic separation of sodium dodecyl sulfate-proteins on a microchip.

A microchip for integrated isotachophoretic (ITP) preconcentration with gel electrophoretic (GE) separation to decrease the detectable concentration of sodium dodecyl sulfate (SDS)-proteins was developed. Each channel of the chip was designed with a long sample injection channel to increase the sample loading and allow stacking the sample into a narrow zone using discontinuous ITP buffers. The pre-concentrated sample was separated in GE mode in sieving polymer solutions. All the analysis steps including injection, preconcentration, and separation of the ITP-GE process were performed continuously, controlled by a high-voltage power source with sequential voltage switching between the analysis steps. Without deteriorating the peak resolution, four SDS-protein analyses with integrated ITP-GE system resulted in a decreased detectable concentration of approximately 40-fold compared to the GE mode only. A good calibration curve for molecular weights of SDS-proteins indicated that the integrated ITP-GE system can be used for qualitative analysis of unknown protein samples.

Calibration↗

Chiral separations on multichannel microfluidic chips.

Chiral separations of FITC-labeled basic drugs on multichannel microfluidic chips with LIF detector were investigated. A preliminary screening procedure for seven neutral CDs was performed under optimized conditions for chiral separations of three FITC-labeled drugs (baclofen, norfenefrine, and tocainide) on a mono-channel microfluidic chip. According to the results of screening, FITC-baclofen and FITC-norfenefrine as well as two chiral selectors including gamma-CD and dimethyl-beta-CD (DM-beta-CD) were selected as models to perform chiral separations on a two-channel chip. FITC-baclofen enantiomers were separated completely by gamma-CD in one channel, while resolution of FITC-norfenefrine enantiomers was achieved by DM-beta-CD in the other channel in the same run. Furthermore, the feasibility of using one chiral selector to separate multiple chiral samples was studied on a four-channel chip. These results show that multichannel chip has a potential for chiral high-throughput screening.

Baclofen↗

Integrated lectin affinity microfluidic chip for glycoform separation.

Lectin affinity chromatography was miniaturized into a microfluidic format, which results in improvement of performance, as compared to the conventional method. A lectin affinity monolith column was prepared in the microchannel of a microfluidic chip. The porous monolith was fabricated by UV-initiated polymerization of ethylene dimethacrylate (EDMA) and glycidyl methacrylate (GMA) in the presence of porogeneities, followed by immobilization of pisum sativum agglutinin (PSA) on the monolith matrix. Using electroosmosis as the driven force, lectin affinity chromatographies of three kinds of glycoprotein, turkey ovalbumin (TO), chicken ovalbumin (CO), and ovomucoid (OM), were carried out on the microfluidic system. All the glycoproteins were successfully separated into several fractions with different affinities toward the immobilized PSA. The integrated system reduces the time required for the lectin affinity chromatography reaction to approximately 3%, thus, the overall analysis time from 4 h to 400 s. Only 300 pg of glycoprotein is required for the whole separation process. Moreover, troublesome operations for lectin affinity chromatography are simplified.

Adsorption↗

Injection by hydrostatic pressure in conjunction with electrokinetic force on a microfluidic chip.

A simple method was developed for injecting a sample on a cross-form microfluidic chip by means of hydrostatic pressure combined with electrokinetic forces. The hydrostatic pressure was generated simply by adjusting the liquid level in different reservoirs without any additional driven equipment such as a pump. Two dispensing strategies using a floating injection and a gated injection, coupled with hydrostatic pressure loading, were tested. The fluorescence observation verified the feasibility of hydrostatic pressure loading in the separation of a mixture of fluorescein sodium salt and fluorescein isothiocyanate. This method was proved to be effective in leading cells to a separation channel for single cell analysis.

Animals↗

Determination of SARS-coronavirus by a microfluidic chip system.

We have developed a new experimental system based on a microfluidic chip to determine severe acute respiratory syndrome coronavirus (SARS-CoV). The system includes a laser-induced fluorescence microfluidic chip analyzer, a glass microchip for both polymerase chain reaction (PCR) and capillary electrophoresis, a chip thermal cycler based on dual Peltier thermoelectric elements, a reverse transcription-polymerase chain reaction (RT-PCR) SARS diagnostic kit, and a DNA electrophoretic sizing kit. The system allows efficient cDNA amplification of SARS-CoV followed by electrophoretic sizing and detection on the same chip. To enhance the reliability of RT-PCR on SARS-CoV detection, duplex PCR was developed on the microchip. The assay was carried out on a home-made microfluidic chip system. The positive and the negative control were cDNA fragments of SARS-CoV and parainfluenza virus, respectively. The test results showed that 17 positive samples were obtained among 18 samples of nasopharyngeal swabs from clinically diagnosed SARS patients. However, 12 positive results from the same 18 samples were obtained by the conventional RT-PCR with agarose gel electrophoresis detection. The SARS virus species can be analyzed with high positive rate and rapidity on the microfluidic chip system.

Autopsy↗