An efficient, automatable template preparation for high throughput sequencing.

Abstract

We have developed a 96-well format for DNA template isolation that can be readily automatable. The template isolation protocol involves simple alkaline lysis chemistry and reversible capture on a silica solid phase. After the cells are lysed, no centrifugation is necessary, as lysate purification, DNA binding, washing, and release occur in 96-well filter plates. Large numbers of templates prepared using the silica purification method have been sequenced and analyzed. The quality of sequence resulting from our method has been compared with that generated from several commercial plasmid preparation protocols. We found sequence quality of the silica bead preparations to be equivalent to or, in some cases, better than those prepared by other methods. This method offers many advantages over other protocols we have used. First, the silica purifications have allowed us to more than double overall laboratory throughput while decreasing our template isolation materials cost at least five-fold. Second, because we have eliminated all centrifugation steps in the protocol, automation has been much simpler. The protocol has also been adapted to purify PCR products for use as templates in subsequent sequencing reactions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Engelstein, T J Aldredge, D Madan, J H Smith, J I Mao, D R Smith, P W Rice. 1998. An efficient, automatable template preparation for high throughput sequencing.. https://doi.org/10.1089/omi.1.1998.3.237

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

FIP: a highly automated beamline for multiwavelength anomalous diffraction experiments.

FIP is a French Collaborating Research Group (CRG) beamline at the European Synchrotron Radiation Facility (ESRF) dedicated exclusively to crystallography of biological macromolecules, with a special emphasis on multiwavelength anomalous diffraction data collection in the 0.7-1.81 A wavelength range. The optics, consisting of long cylindrical grazing-angle mirrors associated with a cryocooled double-crystal monochromator, delivers an optimal beam in the corresponding energy range. The high level of automation, which includes automated crystal centring, automated data-collection management and data processing, makes the use of this beamline very easy. This is illustrated by the large number of challenging structures that have been solved since 1999.

Automation↗

Simultaneous determination of hydrocodone and hydromorphone in human plasma by liquid chromatography with tandem mass spectrometric detection.

A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for the simultaneous analysis of hydrocodone (HYC) and its metabolite hydromorphone (HYM) in human plasma. A robotic liquid handler and a 96-channel liquid handling workstation were used to aliquot samples, to add internal standard (I.S.), and to extract analytes of interest. A 96-well mixed-mode solid-phase cartridge plate was used to extract the analytes and I.S. The chromatographic separation was on a silica column (50 x 3 mm, 5-microm) with a mobile phase consisting of acetonitrile, water and trifluoroacetic acid (TFA) (92:8:0.01, v/v). The run time for each injection was 2.5 min with the retention times of approximately 2.1 and 2.2 min for HYC and HYM, respectively. The tandem mass spectrometric detection was by monitoring singly charged precursor-->product ion transition 300-->199 (m/z) for HYC, and 28-->185 (m/z) for HYM. The validated calibration curve range was 0.100-100 ng/ml, based on a plasma volume of 0.3 ml. The correlation coefficients were greater than or equal to 0.9996 for both HYC and HYM. The low limit of quantitation (LLOQ) was 0.100 ng/ml for both HYC and HYM with signal-to-noise ratio (S/N) of 50 and 10. respectively. The deuterated analytes, used as internal standards, were monitored at mass transitions 303-->199 (m/z) for HYC-d3 and 289-->185 (m/z) for HYM-d3. The inter-day (n= 17) precision of the quality control (QC) samples were < or = 3.5% RSD (relative standard deviation) for HYC and < or = 4.7% RSD for HYM, respectively. The inter-day accuracy of the QC samples were < or = 2.1% RE (relative error) for HYC and < or = 1.8% RE for HYM. The intra-day (n=6) precision and accuracy of the QC samples were < or = 2.6% RSD and < or = 3.0% RE for HYC, and < or = 4.7% RSD and < or = 2.4% RE for HYM. There was no significant deviation from the nominal values after a 5-fold dilution of high concentration QC samples by blank matrix. The QC samples were stable when kept at room temperature for 24-h or experienced three freeze-thaw cycles. The extraction recoveries were 86% for HYC and 78% for HYM. No detectable carryover was observed when a blank sample was injected immediately after a 2500 ng/ml sample that was 25-fold more concentrated than the upper limit of quantitation (ULOQ).

Automation↗