PubMed Health⌕ Search

PubMed · 10029152

Ligament graft initial fixation strength using biodegradable interference screws.

Abstract

The objective of this study was to evaluate the initial fixation strength of three types of biodegradable interference screws [an Endo Fix, 7 x 25 mm polyglycolic acid, non-self-tapping (Acufex); a biodegradable interference screw, 7 x 23 mm poly-L-lactic acid, self-tapping (Arthrex); a Bioscrew, 7 x 25 mm poly-L-lactic acid, self-tapping (Linvatec)] in comparison to a titanium interference screw (Linvatec, 7 x 25 mm) in anterior cruciate ligament reconstruction using a bone-patellar tendon-bone graft. Porcine lower limbs were used. To control for specimen related bias, bone mineral density of each tibia was measured. All specimens were loaded to failure. Failure mode was determined by visual analysis. The maximum load to failure [mean (SD)] was 785 (87) N (titanium screw), 555 (60) N (Acufex), 592 (211) N (Arthrex), and 844 N (Linvatec). The primary fixation strength of the titanium screw and the Linvatec screw was significantly higher (p < 0.05) than the primary fixation strength of the Arthrex screw and the Acufex screw. There was no difference in bone mineral density between the groups. With respect to primary fixation strength, all biodegradable screws were strong enough to allow accelerated rehabilitation. From this point of view the biodegradable screws may be a reasonable alternative to titanium interference screws.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Rupp, R Seil, A Schneider, D M Kohn. 1999. Ligament graft initial fixation strength using biodegradable interference screws.. https://doi.org/10.1002/(sici)1097-4636(1999)48%3A1%3C70%3A%3Aaid-jbm12%3E3.0.co%3B2-p

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Differential lymphocyte reactivity to serum-derived metal-protein complexes produced from cobalt-based and titanium-based implant alloy degradation.

The lymphocyte response to serum protein complexed with metal from implant alloy degradation was investigated in this in vitro study using primary human lymphocytes from healthy volunteers (n = 10). Cobalt chromium molybdenum alloy (Co-Cr-Mo, ASTM F-75) and titanium alloy (Ti-6Al-4V, ASTM F-136) beads (70 microm) were incubated in agitated human serum at 37 degrees C to simulate naturally occurring metal implant alloy degradation processes. Particulate free serum samples that had been incubated with metal were then separated into molecular weight based fractions. The amounts of soluble Cr and Ti within each serum fraction were measured and correlated with lymphocyte proliferation response to the individual serum fractions. Lymphocytes from each subject were cultured with 11 autologous molecular weight based serum fractions either with or without added metal. Two molecular weight ranges of human serum proteins were associated with the binding of Cr and Ti from Co-Cr-Mo and Ti implant alloy degradation (at <30 and 180-250 kDa). High molecular weight serum proteins ( approximately 180 kDa) demonstrated greater lymphocyte reactivity when complexed with Cr alloy and Ti alloy than low (5-30 kDa) and midrange (30-77 kDa) serum proteins. When the amount of lymphocyte stimulation was normalized to both the moles of metal and the moles of protein within each fraction (metal-protein complex reactivity index), Cr from Co-Cr-Mo alloy degradation demonstrated approximately 10-fold greater reactivity than Ti in the higher molecular weight serum proteins ( approximately 180 kDa). This in vitro study demonstrated a lymphocyte proliferative response to both Co-Cr-Mo and Ti alloy metalloprotein degradation products. This response was greatest when the metals were complexed with high molecular weight proteins, and with metal-protein complexes formed from Co-Cr-Mo alloy degradation.

Absorbable Implants↗

Injection molding of chondrocyte/alginate constructs in the shape of facial implants.

Over one million patients per year undergo some type of procedure involving cartilage reconstruction. Polymer hydrogels, such as alginate, have been shown to be effective carriers for chondrocytes in subcutaneous cartilage formation. The goal of our current study was to develop a method to create complex structures (nose bridge, chin, etc.) with good dimensional tolerance to form cartilage in specific shapes. Molds of facial implants were prepared using Silastic ERTV. Suspensions of chondrocytes in 2% alginate were gelled by mixing with CaSO(4) (0.2 g/mL) and injected into the molds. Constructs of various cell concentrations (10, 25, and 50 million/mL) were implanted in the dorsal aspect of nude mice and harvested at times up to 30 weeks. Analysis of implanted constructs indicated progressive cartilage formation with time. Proteoglycan and collagen constructs increased with time to approximately 60% that of native tissue. Equilibrium modulus likewise increased with time to 15% that of normal tissue, whereas hydraulic permeability decreased to 20 times that of native tissue. Implants seeded with greater concentrations of cells increased proteoglycan content and collagen content and equilibrium and decreased permeability. Production of shaped cartilage implants by this technique presents several advantages, including good dimensional tolerance, high sample-to-sample reproducibility, and high cell viability. This system may be useful in the large-scale production of precisely shaped cartilage implants.

Absorbable Implants↗

Programmable biodegradable implants.

Pulsatile release implants were developed that release substances up to 58 days post implantation. With a cylindrical size of 2 mm diameter and 1.8 mm height the matrices can carry as much as 1 mg of drug and allow even for intracranial implantation into a rodent model. The matrices are made of materials that have been used for parenteral applications in humans before such as surface eroding polyanhydrides and bulk eroding poly(D,L-lactic acid) or poly(D,L-lactic acid-co-glycolic acid). The onset of drug release is controlled by the degradation of bulk eroding polymers which are known to exhibit a certain stability over a defined period of time and which start eroding after they reach a critical degree of degradation. The time of drug release onset was found to depend on the molecular weight and the chemical state of the carboxylic acid end of the polymer chain. For testing the onset of release in vivo a nude mouse model was developed where the release of Evan's blue could be observed visually after subcutaneous application. By combining individual matrices with different release onset, a therapeutic system can be composed that releases drugs after implantation at predetermined time points in a preprogrammed way. Potential applications for such matrices is vaccination and local tumor therapy.

Absorbable Implants↗