PubMed · 10068018
Mechanical considerations in impaction bone grafting.
Abstract
In impaction grafting of contained bone defects after revision joint arthroplasty the graft behaves as a friable aggregate and its resistance to complex forces depends on grading, normal load and compaction. Bone mills in current use produce a distribution of particle sizes more uniform than is desirable for maximising resistance to shear stresses. We have performed experiments in vitro using morsellised allograft bone from the femoral head which have shown that its mechanical properties improve with increasing normal load and with increasing shear strains (strain hardening). The mechanical strength also increases with increasing compaction energy, and with the addition of bioglass particles to make good the deficiency in small and very small fragments. Donor femoral heads may be milled while frozen without affecting the profile of the particle size. Osteoporotic femoral heads provide a similar grading of sizes, although fewer particles are obtained from each specimen. Our findings have implications for current practice and for the future development of materials and techniques.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
N T Brewster, W J Gillespie, C R Howie, S P Madabhushi, A S Usmani, D R Fairbairn. 1999. Mechanical considerations in impaction bone grafting.. https://doi.org/10.1302/0301-620x.81b1.8480