PubMed Health⌕ Search

PubMed · 10099513

Mixed-valence compound-based biosensor.

Abstract

A cobalt(II)hexacyanoferrate-based biosensor has been prepared simply by codeposition of an enzyme, together with the electrochemical formation of a cobalt (II)hexacyanoferrate compound electrochemically. The compound can be generated at a constant potential of -0.05 V (vs. Ag/AgCl). This compound possesses the catalytic property of reducing hydrogen peroxide to water at the operating potential of 0.0 V vs. Ag/AgCl. The mixed-valence compound-based biosensor possesses an unique interference-independent feature, which is important for biomedical application; this feature is attributed to the low overvoltage characteristic of cobalt (II)hexacyanoferrate. The electrochemical glucose biosensor responds to a series of glucose injections with linearity up to 5 mM (with correlation coefficient R = 0.9999) and the sensitivity of the linear portion is 733 nA/(cm2 x mM). The detection limit is 2 x 10(-6)M (S/N = 3). Both the potential-dependent electron transfer rate constant and the apparent Michaelis-Menten constant were studied in rotating disk experiments. The apparent Michaelis-Menten constant, Km' calculated from the slope of the "Lineweaver-Burke" type reciprocal plot is 28 mM. A fast-response characteristic is observed in the rotating disk experiment and the 95% response time is 14.5 sec. No response was observed from the addition of either 2 x 10(-4)M galactose, acetaminophen, ascorbic acid, uric acid, cysteine, tyrosine, dopamine, or 1,4-dihydroxyquinone in the absence and/or in the presence of 5 x 10(-4)M glucose.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M S Lin, Y C Wu, B I Jan. 1999-01-05. Mixed-valence compound-based biosensor.. https://doi.org/10.1002/(sici)1097-0290(19990105)62%3A1%3C56%3A%3Aaid-bit7%3E3.0.co%3B2-m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques↗

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques↗

Characterization of multicomponent monosaccharide solutions using an enzyme-based sensor array.

We report the development of a sensor for rapidly and simultaneously measuring multiple sugars in aqueous samples. In this strategy, enzyme-based assays are localized within an array of individually addressable sites on a micromachined silicon chip. Microspheres derivatized with monosaccharide-specific dehydrogenases are distributed to pyramidal cavities anisotropically etched in a wafer of silicon (100) and are exposed to sample solution that is forced through the cavities by a liquid chromatography pumping system. Production of fluorescent reporter molecules is monitored under stopped-flow conditions when localized dehydrogenase enzyme systems are exposed to their target sugars. We demonstrate the capability of this analysis strategy to quantify beta-D-glucose and beta-D-galactose at low micromolar to millimolar levels, with no detectable cross-talk between assay sites. Analysis is achieved either through fluorescence detection of an initial dehydrogenase product (NADH, NADPH) or by production of a secondary fluorescent product created by hydride transfer from the reduced nicotinamide cofactor to a fluorogenic reagent. The array format of this sensor provides capabilities for redundant analysis of sugars and for monitoring levels of other solution components known to affect the activity of enzymes. The use of this strategy to normalize raw fluorescence signals is demonstrated by the determination of glucose and pH on a single chip. Alternatively, uncertainties in the activity of an immobilized enzyme can be accounted for using standard additions, an approach used here in the determination of serum glucose.

Biosensing Techniques↗