PubMed Health⌕ Search

PubMed · 10227180

Optimization of a matrix solid-phase dispersion method with sequential clean-up for the determination of alkylphenol ethoxylates in biological tissues.

Abstract

A modified Matrix Solid-Phase Dispersion (MSPD) method with sequential clean-up has been developed to isolate and purify alkylphenol ethoxylates (APEs) and alkylphenols in biological tissues. Elution profile, sequential clean-up adsorbent and experimental set up were optimized. Octadecylsilica was used as the solid-phase for matrix dispersion. Methanol was found to be the optimal eluting solvent for APEs. Aluminium oxide was quite efficient for removing the coeluting interferences. Quantitative analysis was done by reversed-phase HPLC with fluorescence detection. The optimized procedure was applied to analyze both fish and mussel samples. Average recoveries for all spiked tissue samples were greater than 90%. Typical limits of detection amount to tens of ppbs on a wet weight basis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Zhao, F van der Wielen, P de Voogt. 1999-04-02. Optimization of a matrix solid-phase dispersion method with sequential clean-up for the determination of alkylphenol ethoxylates in biological tissues.. https://doi.org/10.1016/s0021-9673(99)00101-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Structure-activity relationships of mineral dusts as heterogeneous nuclei for ammonium sulfate crystallization from supersaturated aqueous solutions.

Mineral inclusions, present in aqueous atmospheric salt droplets, regulate crystallization when relative humidity decreases by providing a surface for heterogeneous nucleation and thus reducing the critical supersaturation. Although laboratory studies have quantified these processes to some extent, the diverse atmospheric mineralogy presents more chemical systems than practically feasible for direct study. Structure--activity relationships are necessary. To that end, in the present work the interactions of ammonium sulfate with corundum, hematite, mullite, rutile, anatase, and baddeleyite were studied by diffuse reflectance fourier transform infrared spectroscopy (DRIFTS) and by epitaxial modeling. The spectroscopic results show that shifts in sulfate peak positions due to chemisorption are not a correlative indicator of the efficacy of heterogeneous nucleation. In contrast, epitaxial modeling results of unreconstructed surfaces explain the sequence of critical supersaturations for constant particle size. If validated by further work, this computer modeling method would provide an important structure--activity tool for the estimation of heterogeneous nucleation properties of the atmospheric mineralogy.

Aluminum Oxide↗

Electrolytic A12O3 coating on co-cr-mo implant alloys of hip prosthesis.

The ceramic films over metallic implant surfaces have the potential to improve implant performance with respect to implant fixation, wear, or corrosion. In this study, the electrolytic Al2O3 coatings on F-1537 Co-Cr-Mo alloy were conducted in an aqueous solution of Al(NO3)3. Through the cycle polarization test in Hank's solution, it was found that the corrosion potential and protection potential of the alumina-coated were higher than that of the uncoated, and the corrosion current density was lower. The phase transformation of A12O3 film on Co-Cr-Mo alloy annealed at 800 K revealed todlite (5Al2O3 . H2O) and thetaAl2O3 (113) preferred orientation for 20 min, and thetaAl2O3 (200) preferred orientation with eta phase for 80 min. Scanning electron microscopy/energy dispersive spectroscopy observations after the scratch tests showed that the adhesion of the alumina films on Co-Cr-Mo alloy can load a stress over the yield strength (450 MPa) of Co-Cr-Mo alloy. The wear loss of ultra-high molecular-weight polyethylene to the Al2O3-coated specimen was eight times less than that to the uncoated. It is concluded that such Al2O3-coated films on Co-Cr-Mo implant alloy exhibit excellent quality in corrosion, adhesion, and wear for the application of hip prosthesis.

Aluminum Oxide↗

Slurry sampling fluorination assisted electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry for the direct determination of metal impurities in aluminium oxide ceramic powders.

A new analytical procedure for the direct determination of metal impurities (Cr, Cu, Fe and V) in aluminium oxide ceramic powders by slurry sampling fluorination assisted electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry (ETV-ICP-AES) is reported. A polytetrafluoroethylene (PTFE) emulsion was used as a fluorinating reagent to promote the vaporization of impurity elements in aluminium oxide ceramic powders from the graphite tube. A vaporization stage with a long ramp time and a short hold time provided the possibility of temporal analyte-matrix separation. The experimental results indicated that a 10 microL 1% m/v slurry of aluminium oxide could be destroyed and vaporized completely with 600 micrograms PTFE under the selected conditions. Two aluminium oxide ceramic powder samples were used without any additional pretreatment. Analytical results obtained by using standard addition method with aqueous standard solution were checked by comparison of the results with pneumatic nebulization (PN)-ICP-AES based on the wet-chemical decomposition and analyte-matrix separation. The limits of detection (LODs) between 0.30 microgram g-1 (Fe) and 0.08 microgram g-1 (Cu) were achieved, and, the repeatability of measurements was mainly better than 10%.

Aluminum Oxide↗