PubMed Health⌕ Search

PubMed · 10233457

The voiding pattern in infants with dilating reflux.

Abstract

OBJECTIVE: To determine whether the voiding pattern in infants with dilating vesico-ureteric reflux (VUR) differs from that in healthy infants, thus supporting the existence of bladder dysfunction in infants with VUR. PATIENTS AND METHODS: Forty-one infants (33 boys and eight girls) with dilating VUR (grades 3-5) were studied using a noninvasive 4-hourly voiding record described previously in studies of the voiding pattern of healthy infants, and the results compared with those obtained from healthy infants of similar age. RESULTS: The voiding pattern in the boys with VUR was characterized by small frequent voids and interrupted voids in more patients (36%) than in healthy boys (15%). Conversely, the girls with VUR were infrequent voiders of relatively high volumes. Residual urine was significantly increased in both boys and girls, as was bladder capacity, although not significantly. CONCLUSIONS: The free voiding pattern in infants with dilating reflux differs from that seen in healthy infants of comparable age. The characteristics for boys and girls differed but was in accordance with that seen in invasive urodynamic studies, suggesting refluxing infants to have a bladder dysfunction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Sillén, A L Hellström, G Holmdahl, E Sölsnes. 1999. The voiding pattern in infants with dilating reflux.. https://pubmed.ncbi.nlm.nih.gov/10233457/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Computed tomographic enterography adds information to clinical management in small bowel Crohn's disease.

BACKGROUND: CT enterography yields striking findings in the bowel wall in Crohn's disease. These images may help to evaluate whether small bowel narrowing results from active disease requiring anti-inflammatory therapy. However, the clinical relevance of these images is unknown. It is also not known if these radiologic findings correlate with objective biomarkers of inflammation. METHODS: In a blinded and independent evaluation, IBD subspecialty gastroenterologists reviewed clinical data, and CT radiologists reviewed CT enterography scans of 67 consecutive patients with Crohn's disease and suspicion of either small bowel inflammation or stricture. Comparisons were made between (1) clinical and radiologic assessments of inflammation and stricture, (2) clinical assessments before and after computed tomographic enterography (CTE) reports were revealed, and (3) radiologic findings and objective biomarkers of inflammation. RESULTS: (1) Individual CTE findings correlated poorly (Spearman's rho < 0.30) with clinical assessment; (2) clinicians did not suspect 16% of radiologic strictures, and more than half the cases of clinically suspected strictures did not have them on CTE; (3) CTE data changed clinicians' perceptions of the likelihood of steroid benefit in 41 of 67 cases; (4) specific CTE findings correlated with CRP, and a distinct set of CTE findings correlated with ESR in the subset of patients who had these biomarkers measured. CONCLUSIONS: CTE seems to add unique information to clinical assessment, both in detecting additional strictures and in changing clinicians' perceptions of the likelihood of steroids benefiting patients. The biomarker correlations suggest that CTE is measuring real biologic phenomena that correlate with inflammation, providing information distinct from that in a standard clinical assessment.

Constriction, Pathologic↗

Optimization of spatial resolution for peripheral magnetic resonance angiography.

RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.

Constriction, Pathologic↗