PubMed Health⌕ Search

PubMed · 10237538

Shared services.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1975. Shared services.. https://pubmed.ncbi.nlm.nih.gov/10237538/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Promotion of the blood donation in a hospital: comparison of two approaches].

BACKGROUND: Our purpose was to evaluate the results of the promotion of blood donation in patients undergoing stem cell transplantation (SCT) and to compare it with this promotion in remaining in-patients. PATIENTS AND METHODS: The hematologist and the blood bank staff informed the patient undergoing SCT about the need for transfusions. Donors were selected for blood or platelet donation. In remaining in-patients, promotion was performed by the blood bank staff by interviewing patients. RESULTS: Between January 2000 and May 2001, 48 SCT patients were included: 41 (85%) yielded 453 possible donors. Of them, 306 donated blood, 77 platelets and 82 were excluded. The number of donations was 484 (389 whole blood and 105 platelets), and 25% (n = 98) of patients donated blood subsequently. Among in-patients 1,950 interviews were carried out: 533 (27.3%) yielded 901 donors (p < 0.001). Overall, 1,146 blood donations were obtained and 15% (135) of these donors donated blood subsequently (p < 0.001). CONCLUSION: Collaboration of the hematologist in the promotion of blood donation leads to an increase in the rate and frequency of donations.

Blood Banks↗

A national quality assessment scheme for counting residual leucocytes in unfixed leucodepleted products: the effect of standardisation and 48 hour storage.

BACKGROUND: WBC counting, an essential part of quality monitoring of WBC-reduced blood components, is carried out logistically within 48-72 h of collection. The between-laboratory variability and effects of 24-48 h storage were investigated using three major counting technologies. STUDY DESIGN AND METHODS: Samples of RBC and platelets with WBC in the range 0-50/microl were transported by courier. WBC counting was performed on days 1 and 2, by IMAGN 2000, flow cytometry and Nageotte, initially using local protocols and then using a national flow protocol. Up to 15 laboratories participated in each exercise. RESULTS: For "real failed leucodepleted" red cell products, higher levels of variability were observed for flow and Nageotte, as compared to IMAGN. For spiked RBC samples at critical decision making point (3-20 WBC/microl), between-laboratory the coefficients of variation (CVs) were low for IMAGN and were the highest for Nageotte. Flow cytometry CVs were generally high but improved subsequent to standardisation of sampling and the gating strategy. A similar pattern in the variability of results was observed for platelet concentrates. Sign tests using all samples (carried out for each method in each exercise; 25 in total) demonstrated no overall tendency for larger WBC counts to be recorded on day 1 when compared to day 2, although this difference was significant (p < 0.001) in certain cases depending on the nature of the spiked product. CONCLUSIONS: We conclude that while a good performance is achieved using validated automated technologies for low residual leucocyte counting, the unification of reagents and standardisation of sampling and gating strategies are essential in obtaining interchangeable results. Unfixed RBC and platelet samples can generally be stored for 48 h before WBC counting.

Blood Banks↗

A platelet quality assessment scheme for comparing the performance of quality monitoring laboratories in the UK National Blood Service.

This exercise focused on performance of NBS quality monitoring establishments with respect to enumeration of low leucocyte and other quality indexes of platelet concentration. Paired identical leucodepleted platelet samples, spiked with WBC (20 cells/microl) in 'vacuette' or 'pouch' were assessed by participants (n = 20) on days 1, 2 and 5. For low WBC counting, all laboratories gave estimates within acceptable range (+/-25%) and good agreement between storage and assay methods was observed on days 1 and 2. Day 5 results showed greater variability. Under improved performance criteria (+/-15%), only one laboratory under-estimated at days 1 and 2. Similarly, other parameters demonstrated good agreement between storage methods on days 1 and 2. At day 5, mean results were often significantly different to previous days. Improved performance target (+/-15%) will allow identification of non-conformers.

Blood Banks↗