PubMed Health⌕ Search

PubMed · 10257553

A portable ECG simulator.

Abstract

A simple and low cost ECG simulator is described. The output waveform is a narrow pulse followed by a T-wave which extends to about one-half of the period. This waveform is acceptable by the medical staff and provides to the BMET a simple, calibrated waveform. Four switches control the simulator; (1) power on or off; (2) fixed rates of 60 or 120 BPM; (3) filtered or normal; (4) square wave or pulse. The amplitude is calibrated to 1 mv for a three-lead cable and 0.5 mv steps for use with a five-lead cable. An output of 1.8 volts is available for driving auxiliary equipment. An external light-emitting diode provides visual indication in all modes. A push button switch provides manual testing of respiration modules.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L M Walden. A portable ECG simulator.. https://doi.org/10.1097/00004669-198204000-00003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparative evaluation of the swelling and degrees of cross-linking in three organic gel packings for SEC through some geometric parameters.

The size exclusion chromatographic (SEC) behavior of five solvent/polymer systems in three organic column packings based on polystyrene/divinylbenzene (PS/DVB) copolymer, TSK-Gel H(HR), mu-styragel and TSK-Gel H(XL), has been compared. All the packings offer similar characteristics (pore size, particle size and efficiency) but some differences have been found when eluting the same systems. The different elution behavior observed in both polymeric gels has been analyzed in terms of their swelling and cross-linking degrees and of the fractal parameters. From the Universal Calibration plots, values of the chromatographic partition coefficient, K(p), have been obtained and using some equations previously reported, values of the volume fraction of the network in the swollen state have been determined for the three sets of columns. Overall, for a given hydrodynamic volume and solvent-polymeric solute system the fraction of cross-linked polymer in the stationary phase was ordered according to: TSK-Gel H(XL)>mu-styragel>TSK-Gel H(HR). This means an enhanced swelling degree for TSK-Gel H(HR). In general, fractal calculations support the thermodynamic predictions since both the fractal dimension and the pore size can be ordered as TSK-Gel H(HR)>mu-styragel>TSK-Gel H(XL) (in 10 of the 15 situations studied). The exceptions can be explained in terms of strong preferential solvation.

Calibration↗

Sensitive and simple determination of the vasodilator agent dipyridamole in pharmaceutical preparations by phosphorimetry.

The applicability of heavy atom-induced room-temperature phosphorescence to pharmaceutical samples is demonstrated in this work. Thus a new, simple, rapid, and selective phosphorimetric method for dipyridamole determination is proposed. The phosphorescence signals are a consequence of intermolecular protection when analytes are exclusively in the presence of heavy atom salts and sodium sulfite as an oxygen scavenger to minimize RTP quenching. The determination was performed in 0.1 mol L(-1) thallium(I) nitrate and 8 mmol L(-1) sodium sulfite at a measurement temperature of 20 degrees C. The phosphorescence intensity was measured at 635 nm, with excitation at 305 nm. Phosphorescence was easily developed; a linear concentration range was obtained between 0 and 100 ng mL(-1) with a detection limit of 940 ng L(-1), an analytical sensitivity of 2.5 ng mL(-1), and a standard deviation of 2.7% at 60 ng mL(-1) concentration. The method has been successfully applied to the analysis of dipyridamole in a unique Spanish commercial formulation containing 100 ng mL(-1) per capsule. The recovery was 101.6% with 6.5% standard deviation of analytical measurement. The method using the standard addition methodology has been validated.

Calibration↗