PubMed Health⌕ Search

PubMed · 10356476

Simplified repositioning splint construction.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T A Brady, J P Pelle. 1996. Simplified repositioning splint construction.. https://pubmed.ncbi.nlm.nih.gov/10356476/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Engineering temperature-sensitive poly(N-isopropylacrylamide) polymers as carriers of therapeutic proteins.

This study was carried out to engineer N-isopropylacrylamide (NiPAM) polymers that contain protein-reactive N-acryloxysuccinimide (NASI) and hydrophobic alkylmethacrylates (AMAs). These thermoreversible, protein-conjugating polymers hold potential for retention of therapeutic proteins at an application site where tissue regeneration is desired. The lower critical solution temperatures (LCST) of the polymers were effectively controlled by the AMA mole content. The AMAs with longer side-chains were more effective in lowering the LCST. Polymers without NASI exhibited a stable LCST in phosphate buffer and in serum over a 10-day study period. The LCST of polymers containing NASI was found to increase over time in phosphate buffer, but not in serum-containing medium. The LCST increase in phosphate buffer was proportional to the AMA content. The feasibility of localizing a therapeutic protein, recombinant human bone morphogenetic protein-2 (rhBMP-2), to a site of application was explored in a rat intramuscular injection model. The results indicated that polymers capable of conjugating to rhBMP-2 were most effective in localizing the protein irrespective of the LCST (13-25 degrees C). For polymers with no NASI groups, a lower LCST resulted in a better rhBMP-2 localization. We conclude that thermosensitive polymers can be engineered for delivery of therapeutic proteins to improve their therapeutic efficacy.

Acrylic Resins↗

Mechanical strength of tooth fragment reattachment.

The aim of this study was static and fatigue test investigation of the strength of a tooth fragment reattached with adhesives to the tooth body. Central bovine incisor teeth were used, and standardized fragments were obtained by cutting the incisal edge of the selected teeth. All the fragments were reattached using a multistep dentine adhesive system, and the specimens were randomly divided into two groups (A and B). Group B specimens underwent a further dental treatment: a circumferential double chamfer prepared around the external cut interface was filled with light cured composite restorative resin. Static and fatigue bending tests were performed and linear elastic equations were used to analyze and compare the strength of the treated teeth. The results indicated that the static and fatigue bending properties were improved by using reinforcement with composite restorative resin.

Acrylic Resins↗

Preparation and evaluation of ketoprofen floating oral delivery system.

A sustained release system for ketoprofen designed to increase its residence time in the stomach without contact with the mucosa was achieved through the preparation of floating microparticles by the emulsion-solvent diffusion technique. Four different ratios of Eudragit S100 (ES) with Eudragit RL (ERL) were used to form the floating microparticles. The drug retained in the floating microparticles decreased with increase in ERL content. All floating microparticle formulations showed good flow properties and packability. Scanning electron microscopy and particle size analysis revealed differences between the formulations as to their appearance and size distribution. X-ray and DSC examination showed the amorphous nature of the drug. Release rates were generally low in 0.1 N HCl especially in presence of high content of ES while in phosphate buffer pH 6.8, high amounts of ES tended to give a higher release rate. Floating ability in 0.1 N HCl, 0.1 N HCl containing 0.02% Tween 20 and simulated gastric fluid without pepsin was also tested. The formulation containing ES:ERL1:1 (FIII) exhibited high percentage of floating particles in all examined media.

Acrylic Resins↗