A device for measuring relative angular displacement.

Abstract

A simple, inexpensive, and accurate way to measure relative segmental rotations resulting from torsional loadings locally is described. To measure these rotations, we fabricated a planar spatial linkage (open-loop kinematic chain) requiring only one rotational displacement transducer. This paper describes this device, defines its kinematics, and examines its accuracy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R P McCabe, S S Kohles, S V Chelikani, R Vanderby. 1998. A device for measuring relative angular displacement.. https://doi.org/10.1115/1.2798316

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Underestimation of access flow by ultrasound dilution flow measurements.

For hemodialysis access surveillance, flow measurements are increasingly considered important because they identify accesses at risk of thrombosis. Usually these flow measurements are performed with the ultrasound dilution technique. In a previous patient study it was observed that the resulting flow values were systematically low as compared to magnetic resonance flow measurements, but a satisfactory explanation was lacking. In the present study, we will demonstrate by hemodynamic calculations and in vitro experiments that this discrepancy can be explained by a temporary reduction of the access flow rate, caused by the reversed needle configuration during ultrasound dilution flow measurements. In this configuration. blood is injected retrogressively at one needle and flow between the needles is increased, causing an increased dissipation of energy. The proposed explanation is subsequently confirmed in a patient with a loop graft, by measuring the blood velocity by Doppler ultrasound as a function of reversed dialyzer flow rate. Apart from the ultrasound dilution technique, these findings are applicable to other recently proposed methods for measuring access flow that employ the reversed needle configuration.

Biophysics↗

Production of phantom materials using polymer powder sintering under vacuum.

A technique is presented for the production of polymer-based phantom materials from solid polymer powders and various compounds added to adjust x-ray attenuation. After mixing of the finely grained components, the samples are solidified by a sintering process under vacuum. The method described allows a flexible and inexpensive production of phantom materials. Photon attenuation and density can be adjusted by suitable choice of base polymers and additives to mimic a large range of soft tissues and water.

Biophysics↗

Health and safety implications of exposure to electromagnetic fields in the frequency range 300 Hz to 10 MHz.

An international seminar on health effects of exposure to electromagnetic fields (EMF) in the frequency range from 300 Hz to 10 MHz (referred to as the Intermediate Frequency (IF) range) was held in Maastricht, Netherlands, on 7-8 June 1999. The seminar, organized under the International EMF Project, was sponsored jointly by the World Health Organization (WHO), the International Commission on Non-Ionizing Radiation Protection (ICNIRP), and the Government of the Netherlands. This report does not attempt to summarize all of the material presented at the conference, but focuses on sources of exposure, biophysical and dosimetric considerations pertinent to extrapolating biological data from other frequency ranges to IF and identifies potential health concerns and needs for developing exposure guidelines. This paper is based on presentations at the conference and reports of working groups consisting of the speakers and other experts. It concludes with recommendations for further research aimed at improving health risk assessments in this frequency range.

Biophysics↗