PubMed Health⌕ Search

PubMed · 10414679

Acute left ventricular dysfunction and subarachnoid hemorrhage.

Abstract

OBJECTIVE: Severe left ventricular (LV) dysfunction associated with acute subarachnoid hemorrhage (SAH) due to cerebral aneurysm rupture. SETTING: An adult 12-bed surgical intensive care unit of a university hospital. PATIENT: A female patient presenting with SAH (Hunt & Hess grade III) and severe left ventricular dysfunction. INTERVENTIONS: Central venous pressure, arterial blood pressure, extravascular lung water catheter, transesophageal echocardiography, blood gas analysis, electrocardiograms, and chest x-ray for clinical management. MEASUREMENTS AND MAIN RESULTS: On admission to the district hospital, an electrocardiogram (ECG) revealed a sinus rhythm with transient ST elevations. A transesophageal echocardiography showed a left ventricular ejection fraction (LV-EF) of approximately 10%. Severe LV dysfunction required inotropic and vasopressor support to maintain mean arterial pressure above 60 mmHg, while the first measurement of an extravascular lung water catheter revealed a cardiac index of 2.0 L/min/m2 and moderate hypovolemia. Despite stepwise volume loading that increased intrathoracic blood volume--an indicator of cardiac preload--from 719 mL/m2 to 927 mL/m2, cardiac index remained poor. Enoximone lead to a marked increase of cardiac index up to 3.9 L/min/m2 and LV-EF to about 30%, but had to be stopped due to thrombopenia. Surgical clipping of an intracranial aneurysm was postponed because of the impaired cardiac function and was performed on day 18 after admission. Interestingly, neurologic outcome was not as poor as might be expected from the literature. CONCLUSION: Severe left ventricular dysfunction may occur in acute SAH and may necessitate delay of aneurysm surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S G Sakka, E Huettemann, K Reinhart. 1999. Acute left ventricular dysfunction and subarachnoid hemorrhage.. https://doi.org/10.1097/00008506-199907000-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗