Conformal and conformal avoidance radiation therapy are new therapeutic techniques that are generally characterized by high dose gradients. The success of this kind of treatment relies on quality assurance procedures in order to verify the delivery of the treatment. A delivery verification technique should consider quality assurance procedures for patient positioning and radiation delivery verification. A methodology for radiation delivery verification was developed and tested with our tomotherapy workbench. The procedure was investigated for two cases. The first treatment using a torus-shaped target was optimized for 72 beam directions and sequentially delivered as a single slice to a 33 cm diameter cylinder of homogeneous solid water. For the second treatment, a random pattern of energy fluence was helically delivered for two slices to a 9.0 cm diameter phantom containing inhomogeneities. The presented process provides the energy fluence (or a related quantity) delivered through the multileaf collimator (MLC) using the signal measured at the exit detector during the treatment delivery. As this information is created for every pulse of the accelerator, the energy fluence and state for each MLC leaf were verified on a pulse-by-pulse basis. The pulse-by-pulse results were averaged to obtain projection-by-projection information to allow for a comparison with the planned delivery. The errors between the planned and delivered energy fluences were concentrated between +/-2.0%, with none beyond +/-3.5%. In addition to accurately achieving radiation delivery verification, the process is fast, which could translate to radiation delivery verification in real time. This technique can also be extended to reconstruct the dose actually deposited in the patient or phantom (dose reconstruction).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Kapatoes, G H Olivera, P J Reckwerdt, E E Fitchard, E A Schloesser, T R Mackie. 1999. Delivery verification in sequential and helical tomotherapy.. https://doi.org/10.1088/0031-9155%2F44%2F7%2F318

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Covalent immobilization of redox enzyme on electrospun nonwoven poly(acrylonitrile-co-acrylic acid) nanofiber mesh filled with carbon nanotubes: a comprehensive study.

In this work, novel conductive composite nanofiber mesh possessing reactive groups was electrospun from solutions containing poly(acrylonitrile-co-acrylic acid) (PANCAA) and multi-walled carbon nanotubes (MWCNTs) for redoxase immobilization, assuming that the incorporated MWCNTs could behave as electrons transferor during enzyme catalysis. The covalent immobilization of catalase from bovine liver on the neat PANCAA nanofiber mesh or the composite one was processed in the presence of EDC/NHS. Results indicated that both the amount and activity retention of bound catalase on the composite nanofiber mesh were higher than those on the neat PANCAA nanofiber mesh, and the activity increased up to 42%. Kinetic parameters, K(m) and V(max), for the catalases immobilized on the composite nanofiber mesh were lower and higher than those on the neat one, respectively. This enhanced activity might be ascribed to either promoted electron transfer through charge-transfer complexes and the pi system of carbon nanotubes or rendered biocompatibility by modified MWCNTs. Furthermore, the immobilized catalases revealed much more stability after MWCNTs were incorporated into the polymer nanofiber mesh. However, there was no significant difference in optimum pH value and temperature, thermal stability and operational stability between these two immobilized preparations, while the two ones appeared more advantageous than the free in these properties. The effect of MWCNTs incorporation on another redox enzyme, peroxidase, was also studied and it was found that the activity increased by 68% in comparison of composite one with neat preparation.

Acrylates↗

The effect of finishing and polishing procedures on the surface roughness of composite resin materials.

AIMS: The aims of this study were to evaluate the effect of various finishing and polishing procedures on the surface roughness of six different composite resin materials (Artemis Enamel, TPH Spectrum, Filtek A-110, Filtek Supreme Enamel, Solitaire 2, and Filtek P-60) as well as to evaluate the effectiveness of the surface sealant application (BisCover) on the surface roughness after finishing and polishing procedures of tested composites. METHODS AND MATERIALS: Specimens (n=168) measuring 5 mm in diameter x 2 mm in thickness were fabricated in a plexiglass well covered with a Mylar strip using six composite resins. A control group of seven specimens of each material received no polishing after being cured under the Mylar strip. Twenty-one specimens for each composite were randomly divided among three finishing and polishing groups (n=7). Each group was polished using a different system: Carbide bur/Sof-Lex disc, Carbide bur/Enhance disc with polishing paste, and Carbide bur/Edenta composite finishing kit. The average surface roughness (Ra, microm) of the control and treated specimens were measured with the Mitutoyo Surftest-402 Surface Roughness tester. After a surface sealant (BisCover) was applied to all treated specimens, according to manufacturer's instructions, the average roughness (Ra) was measured again. Results were statistically analyzed using analysis of variance (ANOVA) and the post-hoc Scheffe's test at a p<0.05 significance level. RESULTS: Significant differences were found for the surface roughness (p<0.05) with interaction among composite resins and the finishing systems used (p<0.05). Enhance/Biscover finishing and polishing procedure surface was not significantly different from the Mylar strip surface groups (p>0.05). The Mylar strip group was not significantly different from the Sof-Lex/BisCover and Edenta/BisCover groups. The ranking of mean Ra values by materials was as follows: Filtek Supreme Enamel < Filtek A110 < TPH Spectrum < Artemis <Filtek P-60 < Solitaire 2. The ranking of mean Ra values by polishing systems was as follows: Enhance/BisCover < Mylar Strip < Sof-Lex/BisCover < Edenta/BisCover < Sof-Lex < Enhance < Edenta. CONCLUSION: Smoother surfaces were recorded for the Enhance/BisCover and the Mylar strip-formed surface groups. The composite finishing kit Edenta significantly increased the Ra for all tested composites (p<0.05). But after finishing with Edenta, the use of a surface sealant (BisCover) significantly improved the surface smoothness of all tested composites (p<0.05). Use of BisCover surface sealant on anterior and posterior resin composite restorations after finishing and polishing procedures is recommended.

Acrylates↗