PubMed Health⌕ Search

PubMed · 10447912

High-frequency jet ventilation using a helium-oxygen mixture.

Abstract

The physiological basis for the use of helium relates to the relationship described by Poiseuille. During turbulent gas flow, the factors determining the resistance to flow include the density of gas as well as the length and the radius of a tube. While it may not be possible to readily change the latter two, altering the density of the gas is possible by using helium instead of nitrogen. A helium-oxygen combination has been used most commonly to improve air exchange in patients with upper airway obstruction. Anecdotal reports also suggest the beneficial effects of helium during mechanical ventilation in patients with status asthmaticus, hyaline membrane disease, and other pulmonary parenchymal disorders. To date, the clinical reports have utilized helium only with conventional mechanical ventilation. We present a child whose progressive respiratory failure was treated by using high-frequency jet ventilation with a combination of helium and oxygen. The techniques for the delivery of helium and oxygen through the jet ventilator are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J D Tobias, R E Grueber. 1999. High-frequency jet ventilation using a helium-oxygen mixture.. https://doi.org/10.1046/j.1460-9592.1999.00355.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Advances in magnetic resonance imaging of lung physiology.

This review presents an overview of some recent magnetic resonance imaging (MRI) techniques for measuring aspects of local physiology in the lung. MRI is noninvasive, relatively high resolution, and does not expose subjects to ionizing radiation. Conventional MRI of the lung suffers from low signal intensity caused by the low proton density and the large degree of microscopic field inhomogeneity that degrades the magnetic resonance signal and interferes with image acquisition. However, in recent years, there have been rapid advances in both hardware and software design, allowing these difficulties to be minimized. This review focuses on some newer techniques that measure regional perfusion, ventilation, gas diffusion, ventilation-to-perfusion ratio, partial pressure of oxygen, and lung water. These techniques include contrast-enhanced and arterial spin-labeling techniques for measuring perfusion, hyperpolarized gas techniques for measuring regional ventilation, and apparent diffusion coefficient and multiecho and gradient echo techniques for measuring proton density and lung water. Some of the major advantages and disadvantages of each technique are discussed. In addition, some of the physiological issues associated with making measurements are discussed, along with strategies for understanding large and complex data sets.

Helium↗

Optical pumping system design for large production of hyperpolarized.

We present a design for a spin-exchange optical pumping system to produce large quantities of highly polarized 129Xe. Low xenon concentrations in the flowing gas mixture allow the laser to maintain high Rb polarization. The large spin-exchange rate between Rb and 129Xe through the long-lived van der Waals molecules at low pressure, combined with a high flow rate, results in large production rates of hyperpolarized xenon. We report a maximum polarization of 64% achieved for a 0.3 l/h Xe flow rate, and maximum magnetization output of 6 l/h at 22% polarization. Our findings regarding the polarization dependence on temperature, nitrogen partial pressure, and gas mixture flow velocity are also reported.

Helium↗