Engineering in software testing: statistical testing based on a usage model applied to medical device development.

Abstract

When a population is too large for exhaustive study, as is the case for all possible uses of a software system, a statistically correct sample must be drawn as a basis for inferences about the population. A Markov chain usage model is an engineering formalism that represents the population of possible uses for which a product is to be tested. In statistical testing of software based on a Markov chain usage model, the rich body of analytical results available for Markov chains provides numerous insights that can be used in both product development and test planing. A usage model is based on specifications rather than code, so insights that result from model building can inform product decisions in the early stages of a project when the opportunity to prevent problems is the greatest. Statistical testing based on a usage model provides a sound scientific basis for quantifying the reliability of software.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P L Jones, W T Swain, C J Trammell. Engineering in software testing: statistical testing based on a usage model applied to medical device development.. https://pubmed.ncbi.nlm.nih.gov/10459417/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Compliance testing of medical diagnostic x-ray equipment: three years' experience at a major teaching hospital in Western Australia.

The impact of a formal compliance testing program has been evaluated three years post-implementation on a major teaching hospital (Sir Charles Gairdner Hospital) with 46 x-ray tubes located throughout 37 rooms. The mandatory program, implemented by the statutory authority in January 1997, called for all medical (including chiropractic and dental) equipment used in human diagnosis to be tested at prescribed frequencies using established protocols. The application of the required test methods demonstrated various non-compliance issues. Notices of non-compliance were received for approximately 60% of the equipment in the hospital following the equipment's first annual test. The reasons for, and the significance of, failure varied according to equipment category, test category, equipment use and equipment age. However, at the end of the third year of testing, approximately 75% of the tested x-ray units satisfied the compliance criteria. The main reasons for non-compliance were found to be design limitations of old technology and the current radiation legislation that makes it difficult for some older equipment to meet the relatively stringent criteria.

Equipment Safety↗

Effect of home monitoring on a high-risk population.

A large cohort of infants (8,998) at high risk for sudden and unexpected death was followed with home cardiorespiratory monitoring over a five-year period. These infants included premature infants (23-36 weeks post-conceptual age), SIDS siblings, and infants who experienced an Apparent Life-Threatening Event. The overall SIDS rate in this high-risk population was 0.55/1,000, a rate significantly less than the 0.85 deaths/1,000 reported in the "general population" of Georgia over this same time period. In addition, we report our experience with using home monitors as a diagnostic tool, as well as how monitors can actually be cost-effective. Editorial opinions, and lay press summaries of the CHIME study (JAMA, May 2, 2001) imply that home cardiorespirtory monitors are of little value. Despite the fact that the study never made this claim, many clinicians are now referring to this study as evidence that home monitoring is ineffective and not needed. This article disputes those misconceptions about home cardiorespiratory monitors based on our experience with a large high-risk population of infants.

Equipment Safety↗