PubMed Health⌕ Search

PubMed · 10484221

Sonographic detection of normal and abnormal appendix.

Abstract

AIM: The aim of the study was to assess the value of sonography in detecting the normal appendix and in identifying abnormality. METHODS: The appendiceal wall thickness (normal: <3 mm) and ultraluminal contents (abnormal: large appendicolith, non-expressible fluid) were used as the primary criteria to determine the appendiceal status in 716 appendices. In patients who underwent appendicectomy (n = 166), surgical and histopathological findings were correlated with the ultrasound (US) findings; in patients who did not have surgery the reference standard was the clinical consensus based on follow-up. RESULTS: Thirty-four patients out of 179 with abnormal sonographic findings did not undergo appendicectomy and recovered spontaneously; in 22 of these, the US changes were confined to the appendiceal tip. A normal appendix was identified in 537 patients (45.9% of all patients without appendicitis), with histologic verification subsequently obtained in 21. In 76 normal appendices (14.2% out of all normal appendices), luminal dilatation due to non-expressible inspissated faeces resulted in appendiceal outer diameter >6 mm (range, 6.2-12 mm); a histopathologic proof of non-inflamed appendix was obtained in seven of these. CONCLUSIONS: A normal appendix can be visualized in a high percentage of cases and it may present with an outer diameter >6 mm (the widely-accepted upper limit of normal) due to the inspissated faecal material within the lumen. A significant percentage of early appendicitis can resolve spontaneously, especially when confined to the appendiceal tip.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Simonovský. 1999. Sonographic detection of normal and abnormal appendix.. https://doi.org/10.1016/s0009-9260(99)90851-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗