PubMed Health⌕ Search

PubMed · 10488937

Paediatric basic life support: a practical assessment.

Abstract

Current European Resuscitation Council (ERC) guidelines for paediatric basic life support advocate delivery of 20 cycles/min at a compression rate of 100/min and a compression:ventilation ratio of 5:1 (Resuscitation 1997;34:115-27; Resuscitation 1998;37(2):97-100). We have evaluated whether cardiopulmonary resuscitation (CPR) can be delivered at this rate by hospital providers. We recruited 24 rescuers, all of whom had successfully completed a training course in paediatric life support. Each was asked to perform single rescuer CPR on a Resusci-Junior mannequin (Laerdal, Kent, UK) for 5 min, following the current ERC guidelines. Compressions and ventilations were recorded in real time by inductance plethysmography. Maintenance of the 5:1 ratio was ensured by investigator observation. Cycles of CPR in the first and fifth minutes of resuscitation were counted. The average duration of compression, ventilation and 'transfer time' spent between these two activities was calculated as a percentage of the average duration of a cycle of CPR. All 24 rescuers completed 5 min of resuscitation. Twenty-three of 24 were unable to deliver 20 cycles of CPR in either the first minute (range 8-27; median 11; interquartile range (IQR) 10-13.75) or in the fifth minute (8-26; 11.5; 10-13.75). The median (IQR) duration of a cycle of CPR was 5 s in the first and fifth minutes. Transfer time comprised 30% of total cycle time. In this study, over 95% of single rescuers trained in paediatric life support were unable to deliver 20 cycles of CPR/min. The guidelines make no allowance for time spent moving between compression and ventilation activity. Future consensus statements should take account of this transfer time. Any changes in recommendations should obviously be prospectively audited with Utstein-style reporting and studies of practicability.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S D Whyte, J P Wyllie. 1999. Paediatric basic life support: a practical assessment.. https://doi.org/10.1016/s0300-9572(99)00056-8. https://pubmed.health/record/pubmed%3A10488937/paediatric-basic-life-support-a-practical-assessment

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Comparison of ventilation and chest compression performance by bystanders using the Impact Model 730 ventilator and a conventional bag valve with mask in a model of adult cardiopulmonary arrest.

"Bystanders" or lay persons are typically the first caregivers to attend to a victim of out-of-hospital cardiopulmonary arrest. Astronaut crew medical officers (CMO) play a similar role to bystanders aboard the International Space Station (ISS). Studies have demonstrated the importance of bystander cardiopulmonary resuscitation (BCPR) for patient survival before the arrival of emergency medical care. Recent apprehension from bystanders about the threat of contracting communicable diseases during BCPR, however, has led to the consideration of other ventilation systems such as the bag-valve mask (BVM) and automatic transport ventilators (ATV). BVM use is called for during CPR aboard the ISS. This study evaluated the ventilation and compression performance of 40 basic CPR-trained bystanders using either a BVM (adult-sized self-inflating bag with face mask) or an ATV (Model 730 ventilator (M730), Impact Instrumentation, Inc., West Caldwell, NJ). Each two-bystander team gave BCPR to a simulated cardiopulmonary arrest victim using the 2-breath/15-compression cycle for 4 min and then switched roles for another 4-min interval. Compared to BVM use, the M730 led to significantly (p<0.05) lower number of breaths, smaller tidal volumes, airway flows, airway pressures, volume of gas entering the stomach per breath and chest compressions for the 4-min period. The M730 also enabled a bystander to meet the recommendation of 4-breath and compression cycles per minute as per Guidelines 2000. Lastly, ease-of-use scores were significantly higher for the M730 compared to the BVM. Overall, the data suggest that the M730 improves the quality of performance for a bystander performing BCPR.

Cardiopulmonary Resuscitation↗