PubMed Health⌕ Search

PubMed · 10495132

Complementary information on bone ultrastructure from scanning small angle X-ray scattering and Fourier-transform infrared microspectroscopy.

Abstract

Scanning small angle X-ray scattering (scanning SAXS) and Fourier-transform infrared microspectroscopy (FT-IRM) have previously been utilized independently to characterize the structural properties of bone in an anatomical position-resolved fashion. Whereas SAXS provides a direct measure of the physical characteristics of apatitic crystals, FT-IRM assesses structure of both mineral and organic matrix at the molecular level. In the present study both methods were applied to examine the same developing bone tissue from the L-4 vertebra of a 14-month-old (accidental death). A 200-microm-thick section was processed for examination by scanning electron microscopy and SAXS. Spectra were collected at 200 microm spatial resolution at specific locations in cortical and cancellous bone. Parameters determined included total SAXS intensity, crystal thickness (T), and degree and direction of predominant crystal orientation. For FT-IRM analysis, a section 4 microm thick was cut longitudinally from the top of the sample. Spectra of regions 100 x 100 microm2 were acquired from the same locations as the SAXS spectra. Integrated areas of the phosphate nu(1,3) collagen amide I, and carbonate nu2 absorbances, were calculated to obtain mineral: matrix and carbonate:mineral ratios. The relative quantities of types A, B, and labile carbonate (substituted for apatite hydroxyl, phosphate, and surface positions, respectively) were also evaluated. Polarized FT-IRM data were collected to determine molecular orientation of the apatite and collagen components. The results of this study show that the information obtained from the two techniques is complementary. Both SAXS and FT-IRM data revealed that the crystals were significantly larger in the cancellous region compared with the cortical region, that mineralization was greater in the cortex, and that the crystals were oriented to a larger degree in the cancellous compared with the cortical bone. The scanning SAXS measure of crystal thickness was significantly correlated to the FT-IRM measures of crystallinity, type A carbonate substitution, and crystal orientation. In conclusion, it was found that the combined use of SAXS and FT-IRM provides valuable, unique information on structural changes in bone at both the microstructural and ultrastructural level. Although each method can be used individually, the combination of techniques provides additional insights into the mechanism of bone crystal maturation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N P Camacho, S Rinnerthaler, E P Paschalis, R Mendelsohn, A L Boskey, P Fratzl. 1999. Complementary information on bone ultrastructure from scanning small angle X-ray scattering and Fourier-transform infrared microspectroscopy.. https://doi.org/10.1016/s8756-3282(99)00165-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Plasma-controlled nanocrystallinity and phase composition of TiO2: a smart way to enhance biomimetic response.

This contribution sheds light on the role of crystal size and phase composition in inducing biomimetic apatite growth on the surface of nanostructured titania films synthesized by reactive magnetron sputtering of Ti targets in Ar+O(2) plasmas. Unlike most existing techniques, this method enables one to deposit highly crystalline titania films with a wide range of phase composition and nanocrystal size, without any substrate heating or postannealing. Moreover, by using this dry plasma-based method one can avoid surface hydroxylation at the deposition stage, almost inevitable in wet chemical processes. Results of this work show that high phase purity and optimum crystal size appear to be the essential requirement for efficient apatite formation on magnetron plasma-fabricated bioactive titania coatings.

Apatites↗

CO2 laser-induced zonation in dental enamel: a Raman and IR microspectroscopic study.

The gradient of structural alteration and molecular exchange across CO(2) laser-irradiated areas in dental enamel was analyzed by Raman and attenuated total reflectance infrared microspectroscopy. The type and the degree of structural changes in morphologically distinguishable zones within the laser spot vary depending on the laser-irradiation parameters--power (1 and 3 W), treatment time (5 and 10 s), and operational mode (super pulse and continuous wave). Using higher power, irrespective of the operation mode, the enamel tissue ablates and a crater is formed. The prevalent phase at the bottom of the crater is dehydrated O(2) (2-)-bearing apatite, that is, the fundamental framework topology is preserved. Additional nonapatite calcium phosphate phases are located mainly at the slope of the laser crater. No structural transformation of mineral component was detected aside the crater rim, only a CO(3)-CO(2) exchange, which decays with the radial distance. A lower-power laser irradiation slightly roughens the enamel surface and the structural modification of enamel apatite is considerably weaker for continuous wave than for super pulse mode. Prolonged low-power laser treatment results in recrystallization, and thus structural recovering of apatite might be of clinical relevance for enamel surface treatments.

Apatites↗

The in vitro bioactivity of two novel hydrophilic, partially degradable bone cements.

Composite bone cements were prepared with bioactive glasses (MgO-SiO(2)-3CaO.P(2)O(5)) of different reactivities. The matrix of these so-called hydrophilic, partially degradable and bioactive cements was composed of a starch/cellulose acetate blend and poly(2-hydroxyethyl methacrylate). The addition of 30 wt.% of glasses to this system made them bioactive in acellular medium: a dense apatite layer formed on the surface after 7 days of immersion in simulated body fluid. This was demonstrated both by microscopic and infrared spectroscopic techniques. The composition of the glass and, consequently, its structure was found to have important effects on the rate of the apatite formation. The combination of reactivity obtained by one formulation with the hydrophilic and degradable character of these cements makes them a very promising alternative to conventional acrylic bone cements, by allowing a better stabilization of the implant and a stronger adhesion to the bone.

Apatites↗