Improving biosensor analysis.

Abstract

The quality of optical biosensor data must be improved in order to characterize the mechanism and rate constants associated with molecular interactions. Many of the artifacts associated with binding data can be minimized or eliminated by designing the experiment properly, collecting data under optimum conditions and processing the data with reference surfaces. It is possible to globally fit high-quality biosensor data with simple bimolecular reaction models, which validates the technology as a biophysical tool for interaction analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D G Myszka. Improving biosensor analysis.. https://doi.org/10.1002/(sici)1099-1352(199909%2F10)12%3A5%3C279%3A%3Aaid-jmr473%3E3.0.co%3B2-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques↗

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques↗

All solid-state GFP sensor.

An all-solid-state green fluorescent protein (GFP) sensor for GFP measurement was developed. It is immune to interference from ambient light and works with standard flow-through cuvettes. The sensor is practically insensitive to the scattered excitation light encountered in microbial suspensions. It has a range of 0.0002-1 g/L (7.4 x 10(-9) - 3.7 x 10(-5) M) with limit of detection 0.00019 g/L (7.0 x 10(-9) M). The sensor could be used with a UV or blue light emitting diode (LED) as a light source, depending on required sensitivity, selectivity, and background levels. Its very low cost makes it useful in a variety of applications. This article describes the construction and validation of the sensor both off- and on-line in fermentation processes.

Biosensing Techniques↗