PubMed Health⌕ Search

PubMed · 10616872

Equipment acceptance testing: demystifying the process.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Williams. 1999. Equipment acceptance testing: demystifying the process.. https://pubmed.ncbi.nlm.nih.gov/10616872/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Single-photon emission computed tomography in the year 2001: instrumentation and quality control.

OBJECTIVE: SPECT instrumentation is more complex than that used for whole-body and planar imaging, and requires careful quality control to ensure optimum performance. Conventional and new hybrid SPECT imaging systems (coincidence and SPECT/CT) will be discussed. New imaging detector materials such as LSO and CZT will also be discussed, along with their potential advantages. Finally, basic SPECT quality control will be reviewed. After reading this article, the nuclear medicine technologist should be able to: (a) explain the use of single and multihead gamma cameras for SPECT imaging; (b) have an understanding of the potential of new hybrid SPECT imaging systems; (c) be aware of future developments in SPECT imaging technology; (d) understand the requirements for SPECT quality control, including field uniformity and center of rotation corrections; and (e) explain the benefits of using phantoms to augment SPECT quality control.

Gamma Cameras↗

The intraoperative gamma probe: basic principles and choices available.

By taking advantage of the proximity to radioactive sentinel nodes and occult tumors achievable in an operative setting, intraoperative probes are becoming increasingly important in the surgical management of cancer. This article begins with a discussion of the statistical limitations of radiation detection and measurement and of the key performance parameters (sensitivity, energy resolution, and spatial resolution) that characterize detectors. The basic design and operating principle of radiation detectors used in intraoperative probes, scintillation and semiconductor detectors, are then reviewed. Scintillation detector-based intraoperative probes, generally using a NaI(T1) or a CsI(T1) crystal connected to a photomultiplier tube by a fiberoptic cable, have the advantages of reliability, relatively low cost, and high sensitivity, especially for medium- to high-energy photons. Disadvantages include poor energy resolution and scatter rejection, and bulkiness. Semiconductor (CdZn, CdZnTe, HgI2)-based probes are compact and have excellent energy resolution and scatter rejection, but with complex energy spectra reflecting charge-carrier trapping. Their main disadvantage is lower sensitivity. The performance parameters of various commercially available intraoperative probes are then compared. The article concludes with a discussion of the practical considerations in selecting and using intraoperative probes, including ergonomic and other design features, as well as performance parameters.

Gamma Cameras↗

Accuracy in gamma camera measurements of point source velocities.

Mucociliary clearance is impaired in many diseases of the respiratory system. We have developed a method for measuring tracheal mucus velocity by the dynamic study of a single point source of radioactivity deposited in the trachea by cricothyroid injection. Preliminary results suggest that patients with airways disease have very low tracheal mucus velocities (<2 mm x min(-1)). The aim of this experiment was to explore the ability of current scintillation detection systems to track a single point as it moves in a dynamic study in small increments and at low velocity (movements of the order of 1 mm). Background noise was estimated to contribute an error in positioning of 0.16 mm (1 standard deviation). Overall errors in velocity were estimated at 0.2 mm x min(-1). This suggests that standard instrumentation in use in most nuclear medicine departments has the capacity to measure accurately velocities as low as 1 mm x min(-1).

Gamma Cameras↗