Push/pull hemodiafiltration: technical aspects and clinical effectiveness.

Abstract

Push/pull hemodiafiltration (HDF) is characterized by alternate repetition of filtration and backfiltration during hemodialysis with high-flux membrane. In the pressure-controlled push/pull (PC P/P) HDF system, which is the newest push/pull HDF system, there are about 25 repetitions of dilution and concentration of the blood while it passes through the hemodiafilter. Hence, the PC P/P is functionally close to the predilution mode of on-line HDF. In the PC P/P, body fluid is replaced usually by more than 120 L of dialysate during the 4 h treatment. In selecting a hemodiafilter for PC P/P, one must be certain that the blood flow channels in the hemodiafilter do not collapse by the positive pressure on the dialysate side in the backfiltration phase. Thus, the polyacrylonitrile hollow-fiber hemodiafilter and polysulfon hollow-fiber hemodiafilter are suitable for PC P/P. In the short term, PC P/P has been reported to be effective against joint pain, itchiness, insomnia, irritability, and restless leg syndrome experienced by hemodialysis patients. Midterm clinical effectiveness of PC P/P includes the requisite lowering of the erythropoietin dose and improvement in skin pigmentation. The albumin loss per treatment with the PC P/P was significantly lower than that with the conventional HDF approach when a protein-permeable membrane is used. In terms of the removal rate of prolactin, no significant difference was found between PC P/P and conventional HDF. On the other hand, the removal rates of myoglobin and beta2M, where molecular size was smaller than prolactin, was significantly greater with the PC P/P than with conventional HDF.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Miwa, T Shinzato. 1999. Push/pull hemodiafiltration: technical aspects and clinical effectiveness.. https://doi.org/10.1046/j.1525-1594.1999.06173.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗