Normalized BMD as a predictor of bone strength.

Abstract

RATIONALE AND OBJECTIVES: In the noninvasive evaluation of bone quality, bone mineral density (BMD) has been shown to be the single most important predictor of bone strength and osteoporosis-related fracture. Among the methods of measuring BMD, dual x-ray absorptiometry (DXA) has widespread acceptance due to its low radiation, low cost, and high precision. However, DXA measures area BMD instead of true volumetric density; thus, a larger bone will tend to have a high BMD than will a smaller bone. Therefore, the comparison of BMDs of bones of different sizes can be misleading. In this study, the authors tried to compensate for the size effect by normalizing the area BMD with bone size as measured from a standard pelvic radiograph. MATERIALS AND METHODS: The overall method for calculation of normalized BMD included conventional area-based BMD from DXA and the extraction of geometric measures from pelvic radiographs. The database for analysis included 34 femoral neck specimens. Regression analysis was performed between the normalized volumetric BMD, measured from femoral neck region, and the mechanical properties obtained from trabecular bone cubes machined from the same region. RESULTS: After normalization of the area BMD, the coefficient of determination increased from 0.30 to 0.43 for the Young modulus and from 0.27 to 0.37 for bone compressive strength. CONCLUSION: A noninvasive method of normalizing BMD can improve the prediction of bone mechanical properties and has potential in monitoring changes in growing skeletons and in the clinical evaluation of bone quality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Jiang, M L Giger, S M Kwak, M R Chinander, J M Martell, M J Favus. 2000. Normalized BMD as a predictor of bone strength.. https://doi.org/10.1016/s1076-6332(00)80441-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗