PubMed Health⌕ Search

PubMed · 10665307

[The "Year 2000 problem"].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Hempelmann, M Benson, A Junger. 1999. [The "Year 2000 problem"].. https://doi.org/10.1055/s-1999-230

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Toward automated synthesis of oligosaccharides and glycoproteins.

The discovery of previously unknown functions associated with carbohydrates and the study of their structure-function relations are of current interest in carbohydrate chemistry and biology. Progress in this area is, however, hampered by the lack of convenient and effective tools for the synthesis and analysis of oligosaccharides and glycoconjugates. Development of automated synthesis of such materials is necessary to facilitate research in this field. This review describes recent advances in carbohydrate synthesis, with particular focus on developments that have potential application to the automated synthesis of oligosaccharides, glycopeptides, and glycoproteins.

Automation↗

Automated high-performance liquid chromatography method for the determination of rosiglitazone in human plasma.

A robust, fully automated assay procedure for the determination of rosiglitazone (I, BRL-49653) in human plasma has been developed. Plasma concentrations of I were determined using automated sequential trace enrichment of dialysates (ASTED) coupled to reversed-phase high-performance liquid chromatography. Sequential automated dialysis of human plasma samples was followed by concentration of the dialysate by trace enrichment on a C18 cartridge. Drug and internal standard, SB-204882 (II) were eluted from the trace enrichment cartridge by mobile phase (0.01 M ammonium acetate, pH 8-acetonitrile, 65:35, v/v) onto the HPLC column (a Novapak C18, 4 microm, 100x5 mm radial compression cartridge) protected by a Guard-Pak C18 cartridge. The compounds were detected by fluorescence detection, using an excitation wavelength of 247 nm, and emission wavelength of 367 nm. The lower limit of quantitation of the method was 3 ng/ml (200 microl aliquot) with linearity demonstrated up to 100 ng/ml. Within- and between-run precision and accuracy of determination were better than 10% across the calibration range. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can be safely stored for at least 7 months at -20 degrees C. This method has been successfully utilised to provide pharmacokinetic data throughout the clinical development of rosiglitazone.

Automation↗

High-throughput, semi-automated determination of a cyclooxygenase II inhibitor in human plasma and urine using solid-phase extraction in the 96-well format and high-performance liquid chromatography with post-column photochemical derivatization-fluorescence detection.

Compound I, 5-chloro-3-(4-methanesulfonylphenyl)-6'-methyl-[2,3']bipyridinyl, has been found to be a specific inhibitor of the enzyme cyclooxygenase II (COX II). The anti-inflammatory properties of this compound are currently being investigated. HPLC assays for the determination of this analyte in human plasma and human urine have been developed. Isolation of I and the internal standard (II) was achieved by solid-phase extraction (SPE) in the 96-well format. A C8 SPE plate was used for the extraction of the drug from human plasma (recovery >90%) while a mixed-mode (C8/Cation) SPE plate was used to isolate the analytes from human urine (recovery approximately 71%). The analyte and internal standard were chromatographed on a Keystone Scientific Prism-RP guard column (20 x 4.6 mm) connected to a Prism-RP analytical column (150 x 4.6 mm), using a mobile phase consisting of 45% acetonitrile in 10 mM acetate buffer (pH = 4); the analytes eluted at retention times of 5.2 and 6.9 min for I and II, respectively. Compounds I and II were found to form highly fluorescent products after exposure to UV light (254 nm). Thus, the analytes were detected by fluorescence (lambda(ex) = 260 nm, lambda(em) =375 nm) following post-column photochemical derivatization. Eight point calibration curves over the concentration range of 5-500 ng/ml for human plasma and human urine yielded a linear response (R2>0.99) when a 1/y weighted linear regression model was employed. Based on the replicate analyses (n = 5) of spiked standards, the within-day precision for both assays was better than 7% C.V. at all points on the calibration curve; within-day accuracy was within 5% of nominal at all standard concentrations. The between-run precision and accuracy of the assays, as calculated from the results of the analysis of quality control samples, was better than 8% C.V. and within 8% of nominal. I was found to be stable in human plasma and urine for at least 8 and 2 months, respectively. In addition, the human plasma assay was semi-automated in order to improve sample throughput by utilizing a Packard liquid handling system and a Tom-Tec Quadra 96 SPE system. The precision and accuracy of the semi-automated procedure were comparable to the manual procedure. Over 5000 clinical samples have been analyzed successfully using these methods.

Automation↗