PubMed Health⌕ Search

PubMed · 10736861

Polarization-based oxygen sensor.

Abstract

A new approach to oxygen sensing based on the luminescence polarization observed from a novel type of sensor is described. The oxygen sensor consists of an oxygen-sensitive silicone film containing tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) chloride [Ru(dpp)3Cl2] and an oxygen-insensitive film of Styryl 7 in poly(vinyl alcohol). Polarizers are used to select orthogonally polarized emission components from Ru(dpp)3Cl2 and Styryl 7. The polarization of the combined emission was found to be highly sensitive to the partial pressure of oxygen. This method of polarization sensing is generic and can be used with any fluorophore which displays an analyte-dependent change in intensity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Gryczynski, Z Gryczynski, G Rao, J R Lakowicz. 1999. Polarization-based oxygen sensor.. https://doi.org/10.1039/a900364i

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of fluorescence polarization to monitor MHC-peptide interactions in solution.

We describe here fluorescence polarization-based methods to investigate class I MHC-peptide interactions in solution. Fluorescein-labelled peptides were used to determine MHC/peptide complex association and dissociation constants as well as the equilibrium binding constant (KD). Furthermore, we developed a competition assay for the determination of IC50 values of nonlabelled compounds. Both kinetic and equilibrium parameters are of prime importance for the development of immunomodulating compounds. The assays described here show a good reproducibility and require only picomolar amounts of labelled tracers. A high ratio between the experimental values obtained for bound and free labelled ligand as well as a low standard deviation, permits the detection of class I MHC ligands with low affinity. Fluorescence polarization allows the direct measurement of the ratio between free and bound labelled ligand in solution without any separation step. Thus, in combination with microtiter-plates, the time for analysis is significantly decreased to 10 s per sample. Our assays represent versatile tools for characterizing the binding of single ligands as well as for rapid screening of large numbers of compounds.

Fluorescence Polarization↗

Multiphoton fluorescence microscopy.

Multiphoton fluorescence microscopy has now become a relatively common tool among biophysicists and biologists. The intrinsic sectioning achievable by multiphoton excitation provides a simple means to excite a small volume inside cells and tissues. Multiphoton microscopes have a simplified optical path in the emission side due to the lack of an emission pinhole, which is necessary with normal confocal microscopes. This article illustrates examples in which this advantage in the simplified optics is exploited to achieve a new type of measurements. First, dual-emission wavelength measurements are used to identify regions of different phase domains in giant vesicles and to perform fluctuation experiments at specific locations in the membrane. Second, we show how dual-wavelength measurements are used in conjunction with scanning fluctuation analysis to measure the changes in the geometry of the domains and the incipient formation of gel domains when the temperature of the giant vesicles is gradually lowered.

Fluorescence Polarization↗