PubMed Health⌕ Search

PubMed · 10757283

Kinetics of solid-phase extraction and solid-phase microextraction in thin adsorbent layer with saturation sorption isotherm.

Abstract

The effects of sorbent saturation in thin adsorbent layers have been much overlooked in earlier research and should be taken into account in both the theory and practice of solid-phase extraction (SPE) and solid-phase microextraction (SPME). The adsorption kinetics of a single analyte into a thin adsorptive layer was modeled for several cases of agitation conditions in the analyzed volume. The extraction process in the adsorbent layer was modeled using a Langmuir isotherm approximated by the linear isotherm at low concentrations and by a saturation plateau at concentrations exceeding the critical saturation concentration. Laplace transformations were used to estimate the equilibration time and adsorbed analyte concentration profile for no agitation, practical and perfect agitation in the analyzed volume. The equilibration time may be significantly reduced at high degrees of oversaturation and/or agitation in the analyzed volume. The resulting models indicated that the adsorbent layer becomes saturated at some critical value of the oversaturation degree parameter. The critical value of the oversaturation parameter is affected by both the concentration of the analyte in the analyzed volume and the sorbent characteristics. It was also shown that the adsorption process is carried out via the propagation of the saturation adsorption boundary toward the inner boundary of the adsorbent layer. These new adsorption models should serve as "stepping stones" for the development of competitive adsorption kinetic models for both SPE and SPME, particularly in cases where fast sampling is used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S N Semenov, J A Koziel, J Pawliszyn. 2000-03-17. Kinetics of solid-phase extraction and solid-phase microextraction in thin adsorbent layer with saturation sorption isotherm.. https://doi.org/10.1016/s0021-9673(99)01338-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The investigation and the use of high flow column-switching LC/MS/MS as a high-throughput approach for direct plasma sample analysis of single and multiple components in pharmacokinetic studies.

Recently direct plasma injection LC/MS/MS technique has been increasingly used in pharmaceutical research and development due to the demand for higher throughput of sample analyses. In this work, two on-line extraction methods including high flow LC/MS/MS and high flow column switching LC/MS/MS were investigated. The evaluations were conducted and focused on their performances with respect to peak responses, separation efficiency, and signal to-noise ratio in a multiple-component LC/MS/MS assay. Two HPLC pumps were used-with one for high flow delivery and one for gradient elution. A CTC autosampler was used to inject plasma samples. High flow LC was achieved by the use of 4 ml/min flow rate on a 1 x 50 mm Waters Oasis column. A 2 x 100 mm YMC column was coupled via a column-switching valve. The extracted analytes were analyzed in multiple-reaction-monitoring (MRM) mode using a triple quadrupole MS/MS. As a rapid and simple procedure, vortex-mixing plasma and internal standard directly in sample vials completed sample preparation. The high flow column switching method (two-column system) provided sharper peak shape than the conventional high flow method. This effect increased analyte signal-to-noise ratio and sensitivity. Narrower peak width resulted in much better separation efficiency, which was required for multiple compound (N-in-1) analysis. A 2 mm I.D. column resulted in better peak shape and resolution than using a smaller I.D. column. The selected method achieved acceptable recoveries for most of the compounds tested, and it was successfully applied to a 10-in-1 pharmacokinetic (PK) study. The results showed that the dynamic range, lower limit of quantitation, assay accuracy and precision were acceptable for all compounds. Rapid sample preparation eliminated labor intensive and time consuming processes and improved productivity. This high throughput on-line extraction high flow column switching method has been proven particularly useful for multiple component analysis in PK studies.

Chromatography, Liquid↗

Screening approach for chiral separation of pharmaceuticals. Part I. Normal-phase liquid chromatography.

A strategy for rapid screening for the separation of chiral molecules of pharmaceutical interest by normal-phase liquid chromatography using three cellulose/amylose stationary phases is proposed. In a first step, the most important parameters for the separations were determined and studied for their effects by means of experimental designs. Results showed that the cellulose tris-(3,5-dimethylphenylcarbamate), the amylose tris-(3,5-dimethylphenylcarbamate) and the cellulose tris-(4-methylbenzoate) stationary phases have very broad and complementary enantiorecognition properties. The type of organic modifier used in the mobile phase appeared to have a dramatic influence on the quality of the separation. Based on the results of the preliminary study, a screening strategy was developed and successfully applied to a set of 36 diverse drugs. Enantiomeric separation was observed in 89% of cases and the analysis times were usually shorter than 20 min.

Chromatography, Liquid↗

Micellar liquid chromatography: suitable technique for screening analysis.

The screening capability of micellar liquid chromatography (MLC) is discussed using the reported chromatographic data of several sets of compounds (amino acids, beta-blockers, diuretics, phenethylamines, phenols, polynuclear aromatic hydrocarbons, steroids and sulfonamides) and new results (sulfonamides and steroids). The chromatographic data are treated with an interpretive optimisation resolution procedure to obtain the best separation conditions. Usually, the pH and the concentration of surfactant (sodium dodecyl sulfate, SDS, or cetyltrimethylammonium bromide) for the optimal mobile phase were 2.5-3 and < 0.12 M, respectively. The nature and concentration of organic solvent depended on the polarity of the eluted compounds: a low volume fraction of propanol (approximately 1%, v/v) was useful to separate the amino acids, with log P(o/w) < -1 (where P(o/w) is the octanol-water partition coefficient). A greater concentration of this solvent (approximately 5-7%) was needed for compounds in the range -1 < log P(o/w) < 2, as with the studied diuretics and sulfonamides, and a high concentration of propanol (approximately 15%) or a low concentration of butanol (< 10%) had to be used for less polar compounds with 1 < log P(o/w) < 3, such as the beta-blockers. Pentanol (< 6%) was more suitable for the even less polar compounds with log P(o/w) > 3, such as the steroids. For basic drugs such as the phenethylamines (0 < log P(o/w) < 1.7), eluted with a micellar eluent of anionic SDS, propanol was too weak. A study is also shown for mixtures of sulfonamides (log P(o/w) = -1.2 to 1.7) and steroids (log P(o/w) = 3.0-8.1) eluted from conventional C18 columns with SDS mobile phases containing acetonitrile and 1-pentanol, respectively, which are compared with classical acetonitrile-water and methanol-water mixtures. The results complement a previous study on beta-blockers (log P(o/w) = -0.03 to 2.8) and reveal that MLC is a very competitive technique for the screening of compounds against conventional RPLC, due to its peculiar behaviour with regard to the selectivity and elution strength. The concentration of organic solvent needed to obtain sufficiently low retention times (even for highly hydrophobic steroids with log P(o/w) = 7-8) is also appreciably smaller for MLC, which reduces the environmental impact of the mobile phases.

Chromatography, Liquid↗