[Atrial defibrillator].

Abstract

Atrial fibrillation (AF) is a frequent and costly health care problem representing the most common arrhythmia resulting in hospital admission. Total mortality and cardiovascular mortality are significantly increased in patients with AF compared to controls. In addition to symptoms of palpitations, patients with AF have an increased risk of stroke and may also develop decreased exercise tolerance and left ventricular dysfunction. All of these problems may be reversed with restoration and maintenance of sinus rhythm. External electrical cardioversion has been a remarkably effective and safe method for termination of this arrhythmia. Originally described by Lown et al. in 1963, it has been a well accepted mode of acute therapy. However, this technique requires general anesthesia or heavy sedation. Internal atrial defibrillation has been evaluated as an alternative approach to the external technique for over 2 decades. Recent studies have shown that low-energy internal atrial defibrillation using biphasic shocks is an effective and safe means in restoring sinus rhythm in patients with AF and should be considered especially in patients in whom external cardioversion attempts have failed. Implantable Atrial Defibrillator: Recently, a stand alone IAD, the Metrix System (models 3000 and 3020), has entered clinical investigation. Atrial defibrillation is accomplished by a shock delivered between electrodes in the right atrium and the coronary sinus. The right atrium lead has an active fixation in the right atrium. The coronary sinus lead has a natural spiral configuration for retention in the coronary sinus, and can be straightened with a stylet. Both leads are 7 French in diameter and the defibrillation coils are each 6 cm in length. The electrodes may be placed using separate leads, or very soon by using a single bipolar lead. A separate bipolar right ventricular lead is used for R wave synchronization and post shock pacing. The Metrix defibrillator can be used to induce AF by using R wave synchronous shocks and can store intracardiac electrograms (EGMs) for up to 2 minutes from the most recent 6 AF episodes. The device can be programmed into one of the following operating modes: fully automatic, patient activated, monitor mode, bradycardia pacing only, and off. As AF is not life-threatening, in the automatic mode the device is only intermittently active in detecting and treating AF, and this "sleep wake-up" cycle interval is programmable. The device employs extensive processing both for detection and R wave synchronization. In April 1996, the phase I Metrix multicenter clinical trial was started. As of May 1997, a total of 51 Metrix systems had been implanted as part of the phase I multicenter clinical trial. Preliminary data suggest that both defibrillation thresholds and electrograms are stable over time (implant to 3 months). Detection accuracy has been excellent (100% specificity, 92.3% sensitivity) and there have been no errors of R wave selection for synchronization. No proarrhythmias have resulted from over 3700 shocks delivered. The device is effective in electrically converting 96% of the spontaneous episodes of AF. In 27% of episodes several shocks were required because of early recurrence of AF. In 5 patients, the atrial defibrillator was removed: 2 infections, 1 cardiac tamponade, 1 permanent loss of telemetry, 1 patient required His-Bundle ablation because of frequent episodes of drug refractory AF with rapid ventricular response. Initial clinical experience under controlled conditions with the Metrix system suggests that the implantable atrial defibrillator may offer a therapeutic alternative for a subgroup of patients with drug refractory, symptomatic, long lasting, and infrequent episodes of AF. Further efforts must be undertaken to reduce the patient discomfort associated with internal atrial defibrillation in an attempt to make this new therapy acceptable to a larger patient population with AF. (ABSTRACT TRUNCATED)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Jung, B Lüderitz. 2000. [Atrial defibrillator].. https://pubmed.ncbi.nlm.nih.gov/10810804/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A note on a generalized single step theory for any number of hierarchical genomic matrices.

BACKGROUND: The Single Step algorithm allows combining information from genotyped and un-genotyped individuals, provided they are connected by a pedigree. However, current single step theory is limited to a single list of markers. RESULTS: We present a generalized single step (GSS) method that can accommodate any number of hierarchical molecular datasets (e.g. sequence, high and low density arrays) and pedigree, avoiding imputation. We prove that a similar efficient inversion algorithm exists. The method is recursive, starting with the highest marker density scenario. We illustrate the method with simulation and show that GSS can increase predictive accuracy compared to standard single step. R code is provided so that custom scenarios can be easily compared, either with simulated or real data. CONCLUSION: The method developed generalizes extant single step theory to any number of hierarchical molecular relationship matrices, broadening the scenarios where single step can be applied. A topic of particular interest can be ecology field data or human populations where pedigree is not available, but where samples sequenced and genotyped at different densities can exist. GSS can also be a useful tool to optimize allocation of genotyping and / or sequencing resources.

Algorithms↗

cgDist: Nucleotide-level distance calculation from cgMLST allelic profiles.

Bacterial genomic surveillance requires balancing computational efficiency with genetic resolution for effective cluster investigation. cgMLST distance calculations treat all allelic differences as equivalent units, obscuring nucleotide-level variation. Furthermore, single nucleotide polymorphism-based pipelines provide finer resolution at substantially higher computational cost, which limits their routine deployment in surveillance laboratories. We present cgDist, an algorithm that calculates nucleotide-level distances directly from cgMLST allelic profiles, providing finer resolution than allele-count distances by leveraging within-allele nucleotide variation. The cache architecture stores alignment statistics, enabling distance calculation modes without computation and supporting both dataset-specific and schema-complete cache generation. This design enables incremental surveillance analysis, with performance benefits as laboratories accumulate alignment data. cgDist functions as a precision 'zoom lens' for the investigation of clusters identified through initial cgMLST screening. Rather than restructuring population relationships, this targeted approach concentrates enhanced resolution where it is most informative. The algorithm ensures that cgDist distances are greater than or equal to corresponding cgMLST distances, preserving epidemiological interpretability while adding genetic discrimination. By increasing resolution within identified clusters, cgDist may also support outbreak investigation, a potential application that remains to be evaluated on outbreak-derived data.

Algorithms↗

Theseus: fast and optimal affine-gap sequence-to-graph alignment.

MOTIVATION: Sequence-to-graph alignment is a central problem in bioinformatics, with applications in multiple sequence alignment (MSA) and pangenome analysis, among others. However, current algorithms for optimal affine-gap alignment impose high memory and computational requirements, limiting their scalability to aligning long sequences to complex graphs. Practical solutions partially address this problem using heuristic strategies that ultimately trade off optimality for speed. RESULTS: This work presents Theseus, a novel, fast, and optimal affine-gap sequence-to-graph alignment algorithm. Theseus leverages similarities between genomic sequences to accelerate the alignment computation and reduces the overall memory requirements without compromising optimality. To that end, Theseus processes only a subset of the dynamic programming cells, using a sparse-data strategy that enables efficient sequence-to-graph alignment. Moreover, our algorithm supports optimal affine-gap alignment on arbitrary directed graphs, including those with cycles. We evaluate Theseus on two key problems: MSA and pangenome read mapping. For MSA, we compare it against SPOA, abPOA, and POASTA. Theseus is 1.6× to 17.6× faster than POASTA, and 7.3× faster, on average, than SPOA, both optimal aligners. Compared with abPOA, Theseus ensures optimality and scales to the largest problems. For pangenome read mapping, we benchmark Theseus against the alignment stage of the mapping tool vg map, along with the alignment kernels of SPOA, abPOA, and POASTA. Theseus outperforms the other methods, showing a 1.9× to 16.9× speedup on short reads. Moreover, Theseus is 1.5× to 36.3× faster than vg when aligning against synthetic cyclic graphs. AVAILABILITY AND IMPLEMENTATION: Theseus code and documentation are publicly available at https://github.com/albertjimenezbl/theseus-lib.

Algorithms↗