PubMed Health⌕ Search

PubMed · 10843549

Simultaneous quantitative trace analysis of anionic and nonionic surfactant mixtures by reversed-phase liquid chromatography.

Abstract

The aim of this work was to simultaneously analyse mixtures of a polydisperse polyethylene oxide (PEO) nonionic surfactant and an anionic surfactant (sodium dodecylsulphate, SDS) in water containing sodium chloride in order to quantify trace amounts of these mixtures after their adsorption at water-solid interfaces. A fractional factorial design was then used to optimise the separation by ion-pair reversed-phase liquid chromatography as a function of six factors: the chain length of the tetraalkylammonium salt used as ion-pairing reagent which varied from methyl (C1) to n-propyl (C3); the concentration of this ion-pairing salt; the acetonitrile percentage in water used as organic modifier; the flow-rate; the temperature of analysis and also the sodium chloride concentration. The factorial design enabled in a limited number of analyses, not only to determine which factors had significant effects on retention times or on resolution between a pair of nonionic oligomers, but also to modelize and then find the interesting and rugged area where this resolution was optimal as well as the conditions where time of analysis was not prohibitive. After optimisation of HPLC analysis, we used a trace enrichment procedure to quantify very low concentrations of SDS and C12E9 polydisperse PEO in water. A C18 cartridge and a strong anionic exchange cartridge were coupled and the conditions of elution were optimised in order to obtain concentrated samples which were injected in the same eluent than the HPLC mobile phase. Under such conditions, we were able to quantify, in a single run, mixtures of anionic and nonionic surfactants at concentrations as low as 3.6 microg l(-1) for SDS and 2.5 microg l(-1) for each PEO oligomer in water.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F I Portet, C Treiner, P L Desbène. 2000-05-05. Simultaneous quantitative trace analysis of anionic and nonionic surfactant mixtures by reversed-phase liquid chromatography.. https://doi.org/10.1016/s0021-9673(00)00225-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Purification of cell culture-derived human influenza A virus by size-exclusion and anion-exchange chromatography.

A process comprising of size-exclusion chromatography (SEC) and anion-exchange chromatography (AEC) was investigated for downstream processing of cell culture-derived influenza A virus. Human influenza virus A/PR/8/34 (H1N1) was propagated in serum-free medium using MDCK cells as a host. Concentrates of the virus were prepared from clarified and inactivated cell culture supernatants by cross-flow ultrafiltration as described before. SEC on Sepharose 4 FF resulted in average product yields of 85% based on hemagglutination (HA) activity. Productivity was maximized to 0.15 column volumes (cv) of concentrate per hour yielding a reduction in total protein and host cell DNA (hcDNA) to 35 and 34%, respectively. AEC on Sepharose Q XL was used to separate hcDNA from virus at a salt concentration of 0.65 M sodium chloride. Product yields >80% were achieved for loads >160 kHAU/mL of resin. The reduction in hcDNA was 67-fold. Split peak elution and bimodal particle volume distributions suggested aggregation of virions. Co-elution with hcDNA and constant amounts of hcDNA per dose indiciated association of virions to hcDNA. An overall product yield of 52% was achieved. Total protein was reduced more than 19-fold; hcDNA more than 500-fold by the process. Estimation of the dose volume from HA activity predicted a protein content at the limit for human vaccines. Reduction of hcDNA was found insufficient (about 500 ng per dose) requiring further optimization of AEC or additional purification steps. All operations were selected to be scalable and independent of the virus strain rendering the process suitable for vaccine production.

Anions↗

On the quality of the hardness kernel and the Fukui function to evaluate the global hardness.

An approximated hardness kernel, which includes the second derivative with respect to the density of the kinetic energy, the electron-electron coulomb repulsion, and the exchange density functionals, has been tested for the calculation of the global hardness. The results obtained for a series of 40 cations and neutral systems and 16 anions represent in most cases an improvement of the results obtained using the HOMO-LUMO gap approach and indicate the viability of this approach to evaluate global hardness. In addition, the relevance of the Fukui function approximation and the role of the three components of the hardness kernel in the evaluation of the global hardness have been analyzed.

Anions↗

Development of cation/anion "interaction" scales for ionic liquids through ESI-MS measurements.

Electrospray ionization mass spectrometry applied to ionic liquids allowed the study of loosely bonded supramolecules, originating from these organic salts. Based on the observation that ionic liquids formed cationic [C(q+1)X(q)](+) and anionic [C(q)X(q+1)](-) supramolecular aggregates, we have investigated mixed networks, formed by different cations coordinated to a selected anion or by different anions bonded to a given cation, i.e., [C1...X...C2](+) and [X1...C...X2](-), with the aim to build a scale of the cation-anion interaction strength. The qualitative order of intrinsic bond strength to Br- was found to be the following: [emim](+) > [bmim](+) > [mor1,2](+) > [hmim]+ > [omim](+) > [mor1,4](+) > [bupy](+) > [bpyrr](+) > [picol](+) > [bm(2)im](+) > [TBA](+). Similarly, the interaction energies to 1-butyl-3-methylimidazolium (bmim) species envisaged two classes of anions: species tightly coordinated to the cationic moiety that include CF3COO(-), Br(-), N(CN)2(-), and BF4(-) and anions loosely interacting with the alkylimidazolium species such as OTf(-), PF6(-), and Tf2N(-).

Anions↗