PubMed Health⌕ Search

PubMed · 10865776

Body composition measurements during infancy.

Abstract

Infancy is the period of most rapid postnatal growth and is accompanied by major changes in body composition (BC). There are many challenges to successfully measuring BC of infants in vivo, which include the inherent limitations in the underlying assumptions for each technique. The small body mass and rapid nonuniform changes in body parts, that is, the components of BC during infancy, can strain the technical limits of all methods. Many techniques for in vivo BC measurement used in older people have been applied to infants. However, the vast majority of them either are difficult to adapt for widespread use in infants, or the roles and limitations for using them during infancy are ill-defined because of limited or no critical validation and cross-calibration studies. Based on validation data from animals, well-defined methodological issues in data acquisition and analyses, availability of normative data, and pertinent accuracy and precision of the technique to allow us to determinate clinically relevant changes in BC within a reasonable time interval, three techniques appear to be most suitable for in vivo BC measurement in infants. Anthropometric measurements can be used in field studies or for group comparisons, and total body electrical conductivity (TOBEC) and selected dual-energy X-ray absorptiometry (DXA) measurements can be used to compare BC in individual infants. DXA has the advantages of being able to measure bone mass and the potential to be adaptable to the widely available existing instruments. However, regardless of the techniques used in measuring BC in infants, meticulous attention to details in data acquisition and data analysis, and a knowledge of the limitations of the particular technique are the prerequisites for generating valid data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W W Koo. 2000. Body composition measurements during infancy.. https://doi.org/10.1111/j.1749-6632.2000.tb06487.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗