PubMed Health⌕ Search

PubMed · 10867833

Dynamic visual acuity during linear acceleration along the inter-aural axis.

Abstract

We investigated visual-vestibular interactions during linear acceleration along the inter-aural axis. Eighteen healthy volunteers and two patients with central neurological diseases were subjected to transaural linear acceleration in the direction of gravity force (frequency: 0.5-1.5 Hz; amplitude: 5 cm). During linear acceleration, eye movements were recorded under three test conditions: eyes closed (EC), while staring at an imaginary target (IT) and during the testing of dynamic visual acuity (DVA). As parameters of evaluation we used the amplitude of horizontal eye movements, phase shift and the decrease of DVA threshold (DVAT). Under all test conditions, eye amplitude increased with rising stimulus frequency and exceeded, especially in the higher frequency range, a hypothetically calculated eye amplitude for smooth pursuit. The combination of a visual and vestibular input (DVA and IT) led to a better compensation (lower phase shift) than under vestibular stimulation alone (EC). Eye movements during low-frequency stimulation depended more on the visual system while responses in the higher frequency range were mainly triggered by the otolith organ. At 1.5 Hz the compensatory function of the visual-vestibular system was limited (rising phase shift) and DVAT decreased even in a significant number of healthy subjects. Patients with diseases of the central nervous system showed a higher phase shift and thus a stronger decrease of DVAT (two levels) already at a stimulus frequency of 1.25 Hz.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Schmäl, R Kunz, W Stoll. 2000. Dynamic visual acuity during linear acceleration along the inter-aural axis.. https://doi.org/10.1007/s004050050221

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The use of dinoflagellate bioluminescence to characterize cell stimulation in bioreactors.

Bioluminescent dinoflagellates are flow-sensitive marine organisms that produce light emission almost instantaneously upon stimulation by fluid shear in a shear stress dose-dependent manner. In the present study we tested the hypothesis that monitoring bioluminescence by suspended dinoflagellates can be used as a tool to characterize cellular response to hydrodynamic forces in agitated bioreactors. Specific studies were performed to determine: (1) impeller configurations with minimum cell activation, (2) correlations of cellular response and an integrated shear factor, and (3) the effect of rapid acceleration in agitation. Results indicated that (1) at a volumetric mass transfer coefficient of 3 x 10(-4) s(-1), marine impeller configurations were less stimulatory than Rushton configurations, (2) bioluminescence response and a modified volumetric integrated shear factor had an excellent correlation, and (3) rapid acceleration in agitation was highly stimulatory, suggesting a profound effect of temporal gradients in shear in increasing cell stimulation. By using bioluminescence stimulation as an indicator of agitation-induced cell stimulation and/or damage in microcarrier cultures, the present study allows for the verification of hypotheses and development of novel mechanisms of cell damage in bioreactors.

Acceleration↗

Is laparoscopic colorectal surgery less invasive than classical open surgery? Quantitation of physical activity using an accelerometer to assess postoperative convalescence.

BACKGROUND: With the technical advances of recent years, the number of operative manipulations in the abdominal cavity by laparoscopic surgery is now considered to be the same as that using classical open surgery. The question has been raised whether laparoscopic colorectal surgery with lymphadenectomy improves the recovery compared to open surgery. METHODS: We compared patients' physical activity for 7 days postoperatively as measured with an accelerometer between laparoscopic-assisted colorectal resection (LAC, n = 32) and classical open colorectal surgery (OC, n = 30). RESULTS: Physical activity expressed as cumulative acceleration was significantly higher in the LAC than in the OC group on each postoperative day. The recovery time, defined as the day on which the cumulative acceleration recovered to 90% of the preoperative level, was significantly shorter (p < 0.05) in the LAC (3.4 +/- 1.2 days) than in the OC group (6.8 +/- 1.7 days). CONCLUSION: Our results showed that the duration of convalescence with LAC was significantly shorter than that with the OC procedure. Laparoscopic colorectal surgery appears to allow an earlier recovery after the operation than the classical open procedure, and it is less invasive as assessed by convalescence.

Acceleration↗

Influence of task parameters on rotarod performance and sensitivity to ethanol in mice.

Motor performance in mice can be assessed with multiple apparatus and protocols. Use of the rotarod (a.k.a. rotorod, rota-rod, roto-rod, or accelerod) is very common, and it is often used with the apparent assumption by the experimenters that it is a straightforward and simple assay of coordination. The rotarod is sensitive to drugs that affect motor coordination, including ethanol. However, there are few systematic data assessing the range of "normal" performance in mice. There are also few data exploring optimal task parameters (e.g. the influence of different speeds of rotation). In these experiments, we show that both accelerating and fixed-speed rotarod (FSRR) performance vary under different test protocols and conditions, and that moderate to high doses of ethanol disrupt performance. Under certain conditions, low doses of ethanol were found to enhance performance on the accelerating rotarod (ARR). Therefore, it is not possible to characterize individual differences fully using a single set of test parameters. For example, because of the biphasic effect of ethanol on performance, at least two doses of the drug are necessary to explore individual sensitivity differences. We offer recommendations of parameters we believe to be generally suitable for exploring the performance of new genotypes using the rotarod. We suggest that other putative tests of "ataxia" are similarly complex, and that characterizing the contribution of genetic differences will require similar attention to the details of task apparatus and protocols. These data also underscore the need to employ multiple behavioral assays in order to model a complex domain such as "ataxia" or "coordination."

Acceleration↗