Predicting binocular visual field sensitivity from monocular visual field results.

Abstract

PURPOSE: To compare methods of predicting binocular visual field sensitivity of patients with glaucoma from monocular visual field data. METHODS: Monocular and binocular visual fields were obtained for 111 patients with varying degrees of glaucomatous damage in one or both eyes, using the Humphrey 30-2 full-threshold procedure. Four binocular sensitivity prediction models were evaluated: BEST EYE, predictions based on individual values for the most sensitive eye, defined by mean deviation (MD); AVERAGE EYE, predictions based on the average sensitivity between eyes at each visual field location; BEST LOCATION, predictions based on the highest sensitivity between eyes at each visual field location; and BINOCUIAR SUMMATION, predictions based on binocular summation of sensitivity between eyes at each location. Differences between actual and predicted binocular sensitivities were calculated for each model. RESULTS: The average difference between predicted and actual binocular sensitivities was close to zero for the BINOCULAR SUMMATION and BEST LOCATION models, with 95% of all predictions being within +/-3 dB of actual binocular sensitivities. The best eye (MD) prediction had an average error of 1.5 dB (95% confidence limits [CL], +/-3.7 dB). The average eye prediction was the poorest, with an average error of 3.7 dB (95% CL, +/-4.6 dB). CONCLUSIONS: The BINOCULAR SUMMATION and BEST LOCATION models provided better predictions of binocular visual field sensitivity than the other two models, with a statistically significant difference in performance. The small difference in performance between the BINOCULAR SUMMATION and BEST LOCATION models was not statistically significant. For evaluations of functional visual field influences on task performance, daily activities, and related quality-of-life issues, either the BINOCULAR SUMMATION or BEST LOCATION model provides good estimates of binocular visual field sensitivity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Nelson-Quigg, K Cello, C A Johnson. 2000. Predicting binocular visual field sensitivity from monocular visual field results.. https://pubmed.ncbi.nlm.nih.gov/10892865/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗