PubMed Health⌕ Search

PubMed · 10904997

[Computer-assisted cardiotocogram analysis--from descriptive to perinatal expert system].

Abstract

The interpretation of cardiotocograms is essentially for perinatal management, it remains labour intensive and depends on training and experience. With the development of modern analysing systems with conventional classification techniques, it seems possible to introduce expert systems and neuronal networks for a better interpretation and classification of cardiotocograms. Techniques of artificial intelligence are powerful tools and should be integrated in future systems. Because CTG-analysis--as a single procedure--is only of limited value for sufficient fetal prognosis, we conclude that computer aided CTG-analysis in combination with additional fetal parameters, for example partial oxygen pressure, will allow the development of future sufficient perinatal expert systems. Nothing should hinder future integration of computerized cardiotocogram analysing systems into everyday clinical routine and to connect it to obstetrical databases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Seufert, F Woernle, F Casper. 2000. [Computer-assisted cardiotocogram analysis--from descriptive to perinatal expert system].. https://pubmed.ncbi.nlm.nih.gov/10904997/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Beat-to-beat detection of fetal heart rate: Doppler ultrasound cardiotocography compared to direct ECG cardiotocography in time and frequency domain.

In order to obtain power spectral information on the fetal heart rate in stages of pregnancy earlier than labor an algorithm has been developed to calculate the fetal heart rate on a beat-to-beat basis from Doppler ultrasound cardiotocographic signals. The algorithm was evaluated by comparing the calculated fetal heart rate with the heart rate determined from direct ECG signals measured with a scalp electrode. Heart rates were compared both in time and frequency domain. In the time domain the results achieved by both methods correlate well (correlation coefficient = 0.977 (p < 0.001)), in the frequency domain the results correlate even better (correlation coefficient = 0.991 (p < 0.001)). Based on these findings, it can be concluded that the developed algorithm provides a valuable tool for obtaining power spectral information on the fetal heart rate in stages of pregnancy earlier than labor.

Cardiotocography↗

The effects of intrapartum hypoxia on the fetal QT interval.

BACKGROUND: The morphology of the fetal ECG complex provides information on the fetal condition during labour, such as the ST segment and T-wave configuration. We hypothesised that the intrapartum fetal QT interval may provide additional information on the condition of the fetus, as it is known that the QT interval reacts to situations of stress and exercise. DESIGN: Retrospective study. SETTING: Data were substracted from a European community multicentre trial. METHODS: The intrapartum QT interval was measured in 68 fetuses who were acidemic at birth (pH <7.05 and BD (ecf) >12 mmol/L) and in a control group of similar size. All of these cases were monitored by STAN S21. Measurements were performed at the start of the recording at baseline heart rate, during variable decelerations and at the end of the recording. The QTc was calculated using Bazett's formula: QT/ radical RR. The intervals were compared using the Wilcoxon signed ranks test. MAIN OUTCOME MEASURES: Fetal QT interval, and the corrected QT interval: QTc. RESULTS: In the acidemic fetuses, there was a significant shortening of the QTc interval at the end of the recording compared with the start of the recording (397 ms at the end vs 359.3 ms at start; P < 0.001), in association with a significantly lowered heart rate (136.3 vs 110.9 bpm, P < 0.001). Measurements of QT and QTc during variable decelerations at the start and end of the recording also showed a shortening of the QT interval (301.9 vs 273.3 ms, P< or = 0.001) and QTc interval (381.6 vs 340.3, P < 0.001), and this was not dependent on heart rate. In the control cases, no differences in FHR, QT and QTc intervals were present. CONCLUSIONS: In intrapartum hypoxia, resulting in metabolic acidosis, a significant shortening of the fetal QT and QTc is present, irrespective of changes in heart rate. In control cases, this shortening does not occur. The intrapartum fetal QT interval may therefore provide additional information on the condition of the fetus.

Cardiotocography↗