PubMed Health⌕ Search

PubMed · 10944256

A new stacking motif: complex alloy structures interpreted as modulated structures.

Abstract

The structures of lambda-Al4Mn, manganese aluminide, kappa-Al177Cr49Ni, chromium nickel aluminide, and epsilon-Al4Cr, chromium aluminide, which have been described in terms of the aggregation of clusters until now, are interpreted as modulated structures. They are basically composed of close-packed layers with ordered atomic vacancies. The observed stacking motif of the atoms can be found in many phases related to icosahedral and decagonal quasicrystals. This analysis will be helpful in the study of not only many complex alloys, but also quasicrystals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Uchida, Y Matsui. 2000. A new stacking motif: complex alloy structures interpreted as modulated structures.. https://doi.org/10.1107/s0108768100004900

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution.

The effect of surface modification of NiTi shape memory alloy on its corrosion behavior in Hanks' solution was determined. The near-equi-atomic super elastic NiTi (Ni 55.8 wt %) alloy used for this study was provided by Memry USA. The surfaces of heat-treated samples were modified by mechanical polishing (MP), electropolishing (EP), and electropolishing followed by chemical passivation (CP). As-heat-treated samples with straw-colored oxide finishes (SCO) and blue-colored oxide finishes (BO) also were included in the study. Surface analysis was performed using auger electron spectroscopy (AES), atomic force microscopy (AFM), and contact angle measurements (CAM). It was shown that surface roughness increased in the order CP < EP < SCO < BO < MP. The nickel release within the five groups of NiTi samples, as determined by atomic absorption spectrophotometry, reduced in time over the measured period. The level of Ni ions released over a 25-day immersion period was highest in the SCO sample (0.002 microg/day). This Ni level is negligible compared with the daily intake of Ni in an ordinary diet. The auger electron spectroscopy (AES) analyses indicated that before immersion in Hanks' physiologic solution, the main surface composition of all the samples was titanium and nickel, with a small amount of oxygen, carbon, and sulphur as contaminants. And the surface oxide thickness of the different samples increased in the order CP < EP < MP < BO < SCO. On the other hand, for the electrodes treated under the same conditions, the mean breakdown potential value decreased in the order BO > MP > CP > EP > SCO while the corrosion current density and rate increased in the order CP < SCO < EP < BO < MP.

Alloys↗

Attachment, spreading, and matrix formation by human gingival fibroblasts on porous-structured titanium alloy and calcium polyphosphate substrates.

Porous calcium polyphosphate (CPP) structures represent promising resorbable implant systems that can promote anchorage to connective tissues. Previous studies focused on chondrocyte interactions with CPP, but there are limited data on interactions of soft connective tissue cells with these materials. We studied attachment, spreading, and matrix formation by human gingival fibroblasts when cultured on amorphous and crystalline CPP. Comparison with porous Ti6Al4V substrates of similar volume percent, porosity, and pore size distribution provided evaluations of fibroblast interactions with rapid, moderate, and nonbiodegradable systems, respectively. Cells were incubated on substrates in medium containing ascorbic acid and evaluated at 3, 24, 48, 72, and 96 h after plating. Attached cell counts, cytoplasmic actin filament area, and immunostained extracellular type 1 collagen or fibronectin were quantified by morphometric analyses using epifluorescence microscopy. Cell morphology and substrate interactions were evaluated by scanning electron microscopy. Spreading, attachment, and matrix production were similar for both CPP substrates. In contrast, titanium alloy substrates exhibited threefold more attachment and twofold more spreading than CPP substrates. The area per cell of immunostained extracellular collagen and fibronectin was similar for the three different substrates. The results indicate that the crystallinity and, hence, degradation rate of CPP substrates does not substantially affect the interactions of fibroblasts with CPP materials but that compared with titanium alloy substrates, spreading and attachment are inhibited.

Alloys↗

Spectrophotometric determination of serum nitrite and nitrate by copper-cadmium alloy.

A macro and micro assay for the spectrophotometric determination of serum nitrite and nitrate was developed. Nitrite/nitrate in biological samples can be estimated in a single step by this method. The principle of the assay is the reduction of nitrate by copper-cadmium alloy, followed by color development with Griess reagent (sulfanilamide and N-naphthylethylenediamine) in acidic medium. This assay is sensitive to 1 microM nitrate and is suitable for different biological fluids, including sera with a high lipid concentration. The copper-cadmium alloy used in the present method is easy to prepare and can completely reduce nitrate to nitrite in an hour. The present method provides a simple, cost-effective assay for the estimation of stable oxidation products of nitric oxide in biological samples.

Alloys↗