PubMed Health⌕ Search

PubMed · 10961316

High temperature and temperature programming in capillary electrochromatography.

Abstract

In electrochromatography, solvent electrophoretic mobility and solute partitioning are temperature dependent processes. If temperature variations are controlled, solute selectivity and analysis times can be tailored. In this study the feasibility of temperature programming in capillary electrochromatography (CEC) was demonstrated using a reversed-phase CEC mode. The outcome of programmed separations was compared with isothermal, isocratic and isorheic (constant flow) separations. The combined effects of column temperature and mobile phase flow-rate changes during the separation run, resulted in up to a 50% reduction in the separation run time, without adversely affecting the quality of separation. For capillary electrochromatography, temperature programming may be a valuable alternative to solvent programming modes because of the great technical difficulties associated with carrying out solvent gradient elution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N M Djordjevic, F Fitzpatrick, F Houdiere, G Lerch, G Rozing. 2000-07-28. High temperature and temperature programming in capillary electrochromatography.. https://doi.org/10.1016/s0021-9673(99)01129-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel relationship between time offsets in capillary electrophoresis and DNA sequence variations in short tandem repeats.

Next-generation sequencing (NGS) provides increased discriminatory power in forensic DNA analysis due to the detection of isoalleles. Differences in sequences between alleles allow for a second layer of differentiation between DNA contributors beyond the number of short tandem repeat (STR) repeat units. However, because NGS is a more time and resource-intensive analysis than conventional capillary electrophoresis (CE), laboratories may benefit from indicators that suggest NGS is likely to provide added value. This study examined whether CE migration offsets, measured as residuals in the OSIRIS analysis software, can differ significantly among STR isoalleles. Residuals represent the time offset between a sample allele peak and its corresponding allelic ladder peak. Paired CE and NGS data from 95 single source samples were analyzed for CE-based residual differences, as the NGS data provided the sequence information of the corresponding isoalleles. Residual values differed significantly among isoalleles at several STR loci. Statistically significant differences were identified at D16S539 and D3S1358, as well as at specific allele lengths within D12S391, D13S317, and D8S1179. These findings demonstrate that CE residual variation can reflect underlying STR sequence differences between contributors. In practice, residual-based metrics could help laboratories to identify casework reference samples where NGS is likely to provide additional discrimination, without the need for processing outside of a routine CE workflow. Due to the potentially large number of isoalleles, community wide efforts to aggregate CE residual differences versus isoallele sequences may be useful in the validation and implementation of this approach to add value to forensic DNA analyses.

Electrophoresis, Capillary↗

Pre-concentration of non-uniform field electrophoresis for sample introduction of capillary electrophoresis.

A new sample introduction method of capillary electrophoresis, in which field-amplified sample injection was combined with a pre-concentration of non-uniform field electrophoresis, is presented in this paper. With an additional pre-concentration voltage applied to sample solution, a non-uniform electric field was generated, with which analytical cations or anions were pre-concentrated around an electrode adjacent to the injection end of capillary. After the pre-concentration, analytical ions were injected into the capillary and stacked at the boundary between sample and buffer solution inside capillary by field-amplified injection technique. In contrast to the conventional field-amplified injection, larger concentration factor and higher analytical sensitivity were obtained with the improved pre-concentration method. Its concentration factor was about 10 approximately 15 fold as that of field-amplified sample injection.

Electrophoresis, Capillary↗

Fluorogenic assay for beta-glucuronidase using microchip-based capillary electrophoresis.

Microchip capillary electrophoresis (CE) was used with a model enzyme assay to demonstrate its potential application to combinatorial drug screening. Hydrolysis with beta-glucuronidase of the conjugated glucuronide, fluorescein mono-beta-D-glucuronide (FMG), liberated the fluorescent product, fluorescein. FMG and fluorescein were detected by fluorescence, with excitation and emission at 480 and 520 nm, respectively. Microchip CE was used to separate FMG and fluorescein. Fluorescein production was monitored to assess beta-glucuronidase activity. Michaelis-Menten enzyme kinetics analysis yielded the Km value. The results were compared with those from experiments done by conventional CE. The Km value for beta-glucuronidase with FMG is being reported for the first time as 18 microM. The inhibition of beta-glucuronidase by the competitive inhibitor D-saccharic acid-1,4-lactone (SL) was also determined using microchip CE. Reactions were done with various concentrations of inhibitor and constant beta-glucuronidase and FMG concentrations. A dose-response plot was acquired and the IC50 value for SL was determined to be 3 microM.

Electrophoresis, Capillary↗