PubMed Health⌕ Search

PubMed · 10967816

Concerns addressed.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Clark. 2000-07-08. Concerns addressed.. https://pubmed.ncbi.nlm.nih.gov/10967816/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Direct posterior restorations: clinical results and new developments.

The longevity of dental restorations is dependent on many different factors, including those related to materials, the dentist, and the patient. The main reasons for restoration failure are secondary caries, fracture of the bulk of the restoration or of the tooth, and marginal deficiencies and wear. The importance of direct-placement, aesthetic, tooth-colored restorative materials is still increasing. Amalgam restorations are being replaced because of alleged adverse health effects and inferior aesthetic appearance. All alternative restorative materials and procedures, however, have certain limitations. Direct composite restorations require a time-consuming and more costly treatment procedure and are actually only indicated for patients with excellent oral hygiene. Glass ionomers can be considered only as long-term provisional restorations in stress-bearing posterior cavities. Future treatment regimens that are made possible by the development of sophisticated preparation techniques, improved dentin bonding agents, and resin-based restorative materials will result in the therapy of more small-sized lesions rather than large restorations. The importance of indirect inlay techniques will shift more and more toward the direct restoratives. As the cavities become smaller, it is to be expected that the use of improved direct restorative materials will provide excellent longevity even in stress-bearing situations.

Bicuspid↗

Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone.

OBJECTIVES: The purpose of this study was to compare the effects of the diameter, the length and the number of implants on stress distribution in the bone around the implants supporting three-unit fixed partial prostheses in the mandibular posterior edentulism. MATERIALS AND METHOD: A mandibular Kennedy II three-dimensional finite element model was constructed. Four fixed partial prostheses with two terminal implant supports of various lengths and diameters, and two fixed partial prostheses with three implant supports of various lengths were designed. In separate load cases, 400 N oblique, 200 N vertical, and 57 N horizontal forces were simulated. The tensile and the compressive stress values in the cortical bone around the collar of the implants and Von Mises stresses in the implants were evaluated. RESULTS: Although the change in the length of implants did not decrease the stress levels, lower tensile and compressive stress values were observed in the bone for wider implant placement configurations. Similar stress distributions and close stress levels were observed for two wider implant supports in comparison with the three-implant-supported fixed partial prostheses. CONCLUSION: With the use of two implants of 4.1-mm diameter and 10-mm length as terminal supports for three-unit fixed prostheses, the magnitude and the distribution of stresses in the cortical bone around the implant collar is within the normal physiological limits.

Bicuspid↗

Shear bond strengths of plastic brackets with a mechanical base.

This study compares the shear bond strengths of plastic brackets with a mechanical base and metal brackets using two different adhesives, and examines the modes of failure using a scanning electron microscope (SEM). Forty extracted human premolars were selected for bonding. Two types of brackets: metal and plastic-Spirit MB, and two orthodontic adhesives: System 1 + and Enlight, were used. After bonding, all samples were put into a 37 degrees C distilled water bath for 24 hours before shear bond strengths were tested. The bond strengths of the plastic brackets were significantly lower than those of the metal brackets (P < .0001). There was a statistically significant difference in bond strengths between System 1 + and Enlight for plastic brackets (P < .05), but not for metal brackets. The modes of failure predominantly occurred at the enamel/adhesive interface in the metal bracket-System 1 + group, within the adhesive in the metal bracket-Enlight and plastic bracket-System 1 + groups, and at the bracket/adhesive interface in the plastic bracket-Enlight group.

Bicuspid↗