Nitric oxide delivery during high-frequency oscillatory ventilation.

Abstract

BACKGROUND: Inhaled nitric oxide (NO) is used increasingly in the care of infants with hypoxemic respiratory failure and is frequently combined with high-frequency oscillation (HFO). The aim of this study was to evaluate delivery of NO during HFO using titration into the ventilator circuit or using the INOvent Delivery System. METHODS: NO was delivered into the HFO circuit at three sites (pre-humidifier, post-humidifier, and after the bellows) by continuous titration using a rotameter. The target NO concentration ([NO]) was initially adjusted using a rapid-response chemiluminescence NO analyzer without oscillation at 5, 10, and 20 parts per million (ppm). During the study, gas was sampled 5 cm from the bellows (proximal), 35 cm from the bellows (middle), and at the distal end of the circuit (distal). The ventilator was set at frequencies of 5, 10, and 15 Hz, mean airway pressures of 15, 20, and 25 cm H(2)O, and amplitudes of 20, 30, and 40 cm H(2)O. Soft and hard circuits were evaluated. The fraction of inspired oxygen was 0. 90, the inspiratory time fraction was 33%, and the bias flow was 20 L/min throughout the study. An INOvent Delivery System was also evaluated with the same HFO settings. RESULTS: The fluctuation of [NO] was minimal with continuous titration pre-humidifier at all HFO settings. [NO] fluctuated with titration post-humidifier and after the bellows, especially at the proximal sampling site. At the lung model, however, fluctuation of [NO] was always < 1.5 ppm and usually < 1 ppm. Delivered [NO] was lower than target [NO] with injection after the bellows (> 5%). The soft circuit showed better mixing of NO than the hard circuit. The INOvent Delivery System delivered a stable and accurate [NO] at all settings. [NO(2)] was < 1 ppm at all settings. CONCLUSIONS: Mixing of NO during HFO was acceptable at all the injection sites evaluated, although injection pre-humidifier was preferable because of small fluctuations of [NO]. The INOvent Delivery System was simple to use and delivered an accurate and precise [NO] during HFO.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Fujino, R M Kacmarek, D R Hess. 2000. Nitric oxide delivery during high-frequency oscillatory ventilation.. https://pubmed.ncbi.nlm.nih.gov/10980101/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Concurrent carbogen and radiation therapy in children with high-risk brainstem gliomas.

In an attempt to improve local control, we assessed the feasibility of the addition of 4 min of carbogen inhalation (as a radiosensitizer) to daily fractionated radiotherapy in pediatric patients with high grade and/or diffuse brainstem gliomas. Ten patients inhaled carbogen for >90% of the radiation treatments. Median survival time from start of therapy was 0.80 years. Carbogen inhalation did not appear to improve the dismal prognosis.

Administration, Inhalation↗

2. Advances in pharmacotherapy for COPD.

Chronic obstructive pulmonary disease (COPD) is the most common chronic lung disease in the world. In 1999, COPD ranked sixth among the most common causes of death and twelfth as a worldwide burden of disease. It has been estimated that by the year 2020 COPD will be the third leading cause of death and fifth as a worldwide burden of disease. Thus, COPD is a major medical problem and there is evidence that it is increasing throughout the world. Despite recognition of COPD as an important international health problem, COPD has been neglected among common diseases, with little investment in research on its underlying cellular and molecular mechanisms. Recently, global and Japanese guidelines for COPD have been published. These guidelines seem to be useful to improve the underdiagnosis and undertreatment of COPD. In this review, I describe briefly the current recommendation for pharmacological therapy of stable COPD according to the global and Japanese guidelines for COPD.

Administration, Inhalation↗