Additive noise properties of active matrix flat-panel imagers.

Abstract

A detailed theoretical and empirical investigation of additive noise for indirect detection, active matrix flat-panel imagers (AMFPIs) has been performed. Such imagers comprise a pixelated array, incorporating photodiodes and thin-film transistors (TFTs), and an associated electronic acquisition system. A theoretical model of additive noise, defined as the noise of an imaging system in the absence of radiation, has been developed. This model is based upon an equivalent-noise-circuit representation of an AMFPI. The model contains a number of uncorrelated noise components which have been designated as pixel noise, data line thermal noise, externally coupled noise, preamplifier noise and digitization noise. Pixel noise is further divided into the following components: TFT thermal noise, shot and 1/f noise associated with the TFT and photodiode leakage currents, and TFT transient noise. Measurements of various additive noise components were carried out on a prototype imaging system based on a 508 microm pitch, 26 x 26 cm2 array. Other measurements were performed in the absence of the array, involving discrete components connected to the preamplifier input. Overall, model predictions of total additive noise as well as of pixel, preamplifier, and data line thermal noise components were in agreement with results of their measured counterparts. For the imaging system examined, the model predicts that pixel noise is dominated by shot and 1/f noise components of the photodiode and TFT at frame times above approximately 1 s. As frame time decreases, pixel noise is increasingly dominated by TFT thermal noise. Under these conditions, the reasonable degree of agreement observed between measurements and model predictions provides strong evidence that the role of TFT thermal noise has been properly incorporated into the model. Finally, the role of the resistance and capacitance of array data lines in the model was investigated using discrete component circuits at the preamplifier input. Measurements of preamplifier noise and data line thermal noise components as a function of input capacitance and resistance were found to be in reasonable agreement with model predictions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Maolinbay, Y El-Mohri, L E Antonuk, K W Jee, S Nassif, X Rong, Q Zhao. 2000. Additive noise properties of active matrix flat-panel imagers.. https://doi.org/10.1118/1.1286721

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Compliance of electronic personal neutron dosemeters with the new International Standard IEC 61526.

The recommendations and test requests for the dose equivalent response of personal neutron dosemeters formulated by the new International Standard IEC 61526 are summarised. In particular, IEC 61526 allows the use of broad fields if dosemeters do not fulfil the hard requirements using monoenergetic neutrons. Some broad fields which can work as a replacement field using ISO sources (252Cf, 252Cf (D2O mod.), 241Am-Be) and simulated workplace fields (CANEL and SIGMA) are described. This work shows the results of recent measurements of the personal dose equivalent response for the dosemeters Thermo Electron EPD-N2, Aloka PDM-313 and the prototype dosemeter PTB DOS-2002, and discusses their compliance with respect to the new IEC 61526 standard.

Electronics↗

Treatment of waste printed wire boards in electronic waste for safe disposal.

The printed wire boards (PWBs) in electronic waste (E-waste) have been found to contain large amounts of toxic substances. Studies have concluded that the waste PWBs are hazardous wastes because they fails the toxicity characteristic leaching procedure (TCLP) test with high level of lead (Pb) leaching out. In this study, two treatment methods - high-pressure compaction and cement solidification - were explored for rendering the PWBs into non-hazardous forms so that they may be safely disposed or used. The high-pressure compaction method could turn the PWBs into high-density compacts with significant volume reduction, but the impact resistance of the compacts was too low to keep them intact in the environment for a long run. In contrast, the cement solidification could turn the PWBs into strong monoliths with high impact resistance and relatively high compressive strength. The leaching of the toxic heavy metal Pb from the solidified samples was evaluated by both a dynamic leaching test and the TCLP test. The dynamic leaching results revealed that Pb could be effectively confined in the solidified products under very harsh environmental conditions. The TCLP test results showed that the leaching level of Pb was far below the regulatory level of 5mg/L, suggesting that the solidified PWBs are no longer hazardous. It was concluded that the cement solidification is an effective way to render the waste PWBs into environmentally benign forms so that they can be disposed of as ordinary solid wastes or beneficially used in the place of concrete in some applications.

Electronics↗

Evaluation of dose equivalent by the electronic personal dosemeter for neutron 'Saphydose-N' at different workplaces of nuclear facilities.

This paper presents the results of measurements made with the electronic personal neutron Saphydose-N during the four campaigns of the European contract EVIDOS (EValuation of Individual DOSimetry in mixed neutron and photon radiation fields). These measurements were performed at Institute for Radiological Protection and Nuclear Safety (IRSN) in France (C0), at the Krümmel Nuclear Power Plant in Germany (C1), at the VENUS Research Reactor and the Belgonucléaire fuel processing plant in Belgium (C2) and at the Ringhals Nuclear Power Plant in Sweden (C3). The results for Saphydose-N are compared with reference values for dose equivalent.

Electronics↗