PubMed Health⌕ Search

PubMed · 10985357

Three-dimensional shape coding in inferior temporal cortex.

Abstract

Neurons in the rostral lower bank of the superior temporal sulcus (TEs), part of the inferior temporal cortex, respond selectively to three-dimensional (3D) shapes. We have investigated how these neurons represent disparity-defined 3D structure. Most neurons were selective for either first-order (disparity gradients) or second-order (disparity curvature) disparities. The latter selectivity proved remarkably vulnerable to disparity discontinuities, such as sharp edges or steps in disparity. The majority of the neurons remained selective for small disparity variations within the stimulus. 3D shape selectivity was preserved when the frontoparallel position or the stimulus size was altered. Thus, in TEs, 3D shape is coded by first- and second-order disparity-selective neurons, which are highly sensitive to spatial variations of disparity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Janssen, R Vogels, G A Orban. 2000. Three-dimensional shape coding in inferior temporal cortex.. https://doi.org/10.1016/s0896-6273(00)00045-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature motorized microdrive and commutator system for chronic neural recording in small animals.

The use of chronically implanted electrodes for neural recordings in small, freely behaving animals poses several unique technical challenges. Because of the need for an extremely lightweight apparatus, chronic recording technology has been limited to manually operated microdrives, despite the advantage of motorized manipulators for positioning electrodes. Here we describe a motorized, miniature chronically implantable microdrive for independently positioning three electrodes in the brain. The electrodes are controlled remotely, avoiding the need to disturb the animal during electrode positioning. The microdrive is approximately 6 mm in diameter, 17 mm high and weighs only 1.5 g, including the headstage preamplifier. Use of the motorized microdrive has produced a ten-fold increase in our data yield compared to those experiments done using a manually operated drive. In addition, we are able to record from multiple single neurons in the behaving animal with signal quality comparable to that seen in a head-fixed anesthetized animal. We also describe a motorized commutator that actively tracks animal rotation based on a measurement of torque in the tether.

Action Potentials↗

The interaction between membrane kinetics and membrane geometry in the transmission of action potentials in non-uniform excitable fibres: a finite element approach.

By solving the partial differential equations for an axonal segment using a finite element method, the interaction between membrane kinetics and axonal inhomogeneities, measured by their influence on propagated action potentials and stochastic spike trains, is investigated for Morris-Lecar and Hodgkin-Huxley membrane models. To facilitate comparisons of both kinetic models, parameter values are matched to give approximately the same speed for propagated action potentials. In all cases examined, the Morris-Lecar membrane model is more sensitive to geometric inhomogeneities than the comparable Hodgkin-Huxley membrane model. This difference in sensitivity can, in part, be attributed to significant differences in the membrane current supplied by each kinetic model ahead of the action potential. Also, the Morris-Lecar membrane model did not generate reflected action potentials whereas these were observed over a narrow range of geometric parameters for the comparable Hodgkin-Huxley membrane model. Simulations using stochastic spike train input showed that the presence of a sharp flare could significantly modify the statistical characteristics of the spike train output. The behaviour of action potentials governed by Morris-Lecar kinetics were more sensitive to changes in axonal geometry than those generated by comparable Hodgkin-Huxley kinetics. As a consequence of the fine balance between membrane kinetics and axon geometry, local changes in membrane properties, such as those caused by synaptic activity, can be expected to have a strong influence on the behaviour of stochastic spike trains at regions of changing axonal geometry.

Action Potentials↗

Determination of release and uptake parameters from electrically evoked dopamine dynamics measured by real-time voltammetry.

Quantifying mechanisms underlying extracellular signaling by the neurotransmitter dopamine (DA) is a difficult task, particularly in the complex extracellular microenvironment of the intact brain. In this study, two methods for evaluating release and uptake from DA dynamics monitored by real-time voltammetry are described. Both are based on a neurochemical model characterizing electrically evoked levels of DA as a balance between these opposing mechanisms. The theoretical basis of what is called here nonlinear regression and single curve analyses is given. Fitting simulated data tests the reliability of the methods. The two analyses are also compared with an experimental data set describing the effects of pharmacologically inhibiting the DA transporter in the caudate-putamen (CP) and nucleus accumbens (NAc). The results indicate that nonlinear regression and single curve analyses are suitable for quantifying release and uptake mechanisms underlying DA neurotransmission. Additionally, the most important experimental finding of this technical study was the independent confirmation of high affinity (approximately 0.2 microM) DA uptake in the intact striatum.

Action Potentials↗