PubMed · 11039421

Bioadhesives for intraocular use.

Abstract

BACKGROUND/PURPOSE: A safe, effective adhesive could be useful in the management of retinal holes or tears and selected complicated retinal detachments, as well as for attaching a small electronic device (retinal prosthesis) to the retina. In this study, we examined nine commercially available compounds for their suitability as intraocular adhesives. METHODS: The following materials were studied: commercial fibrin sealant, autologous fibrin, Cell-Tak, three photocurable glues, and three different polyethylene glycol hydrogels. An electronic strain gauge measured the adherence forces between different glues and the retina. The stability of hydrogels at body temperature and the impermeability of the hydrogel adhesive to dextran blue were examined. Long-term biocompatibility testing of the most promising glues in terms of adhesive force, consistency, and short-term safety (hydrogels) were done in rabbits. Funduscopy, electroretinogram, and histology of the retina were performed. RESULTS: Hydrogels had 2 to 39 times more adhesive force (measured in mN) than the other glues tested. They liquefied at body temperature after 3 days to a few months. Hydrogels were impermeable to dextran blue. One type of hydrogel proved to be nontoxic to the retina. CONCLUSIONS: Hydrogels proved to be superior for intraocular use in terms of consistency, adhesiveness, stability, impermeability, and safety.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Margalit, G Y Fujii, J C Lai, P Gupta, S J Chen, J S Shyu, D V Piyathaisere, J D Weiland, E De Juan, M S Humayun. 2000. Bioadhesives for intraocular use.. https://doi.org/10.1097/00006982-200009000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of capillary condensation on friction force and adhesion.

Friction force measurements have been conducted with a colloid probe on mica and silica (both hydrophilic and hydrophobized) after long (24 h) exposure to high-humidity air. Adhesion and friction measurements have also been performed on cellulose substrates. The long exposure to high humidity led to a large hysteresis between loading and unloading in the friction measurements with separation occurring at large negative applied loads. The large hysteresis in the friction-load relationship is attributed to a contact area hysteresis of the capillary condensate which built up during loading and did not evaporate during the unloading regime. The magnitude of the friction force varied dramatically between substrates and was lowest on the mica substrate and highest on the hydrophilic silica substrate, with the hydrophobized silica and cellulose being intermediate. The adhesion due to capillary forces on cellulose was small compared to that on the other substrates, due to the greater roughness of these surfaces.

Adhesiveness↗

Evaluation of bond strength of soft relining materials to denture base polymers.

OBJECTIVES: To evaluate the initial bonding properties of recently and previously introduced soft relining materials to denture base polymers with different polymerization techniques and different water content. METHODS: The initial tensile bond strength of 10 soft liners (Mollosil Plus, Dentusil, Ufi gel Soft, GC Reline Soft, Silagum Comfort, Vertex Soft, Astron Soft, Molloplast B, Flexacryl Soft, Triad Resiline) to three denture base polymers (Paladon 65, Palapress Vario, Ivocap Plus) were assessed with a modified method. Paladon 65 specimens immersed in water for 3 months were also used to test the effect of water content of denture base polymer on bond strength results. After testing, a visual examination of the fracture surfaces and a SEM investigation of the interface structure were performed. Tensile strength of each soft liner material was also tested. Data were analyzed statistically by two-way ANOVA (alpha = 0.05). RESULTS: Significant differences were found among tensile bond strength results (P < 0.05). Vinyl poly(organosiloxane) soft liners (Mollosil Plus, Dentusil, Ufi gel Soft, GC Reline Soft, Silagum Comfort) and a plasticized PMMA soft liner (Vertex Soft) gave statistically similar bond strength results for different denture base polymers (P>0.05). For the other materials used (Astron Soft, Molloplast B, Flexacryl Soft, Triad Resiline), different denture base polymers caused significantly different results (P < 0.05). Poly(organosiloxane) based materials gave slightly higher bond strength results with water immersed specimens than with the dry specimens. SIGNIFICANCE: A wide variety of newly formulated soft liners used in this study gave comparable or better bond strength results compared to Molloplast B.

Adhesiveness↗

Flat and sigmoidally curved contact zones in vesicle-vesicle adhesion.

Using the membrane-bending elasticity theory and a simple effective model of adhesion, we study the morphology of lipid vesicle doublets. In the weak adhesion regime, we find flat-contact axisymmetric doublets, whereas at large adhesion strengths, the vesicle aggregates are nonaxisymmetric and characterized by a sigmoidally curved, S-shaped contact zone with a single invagination and a complementary evagination on each vesicle. The sigmoid-contact doublets agree very well with the experimentally observed shapes of erythrocyte aggregates. Our results show that in identical vesicles with large to moderate surface-to-volume ratio, the sigmoid-contact shape is the only bound morphology. We also discuss the role of sigmoid contacts in the formation of multicellular aggregates such as erythrocyte rouleaux.

Adhesiveness↗