PubMed Health⌕ Search

PubMed · 11077737

CPR artifact removal from human ECG using optimal multichannel filtering.

Abstract

The purpose of this study was to assess whether the artifacts presented by precordial compressions during cardiopulmonary resuscitation could be removed from the human electrocardiogram (ECG) using a filtering approach. This would allow analysis and defibrillator charging during ongoing precordial compressions yielding a very important clinical improvement to the treatment of cardiac arrest patients. In this investigation we started with noise-free human ECGs with ventricular fibrillation (VF) and ventricular tachycardia (VT) records. To simulate a realistic resuscitation situation, we added a weighted artifact signal to the human ECG, where the weight factor was chosen to provide the desired signal-to-noise ratio (SNR) level. As artifact signals we used ECGs recorded from animals in asystole during precordial compressions at rates 60, 90, and 120 compressions/min. The compression depth and the thorax impedance was also recorded. In a real-life situation such reference signals are available and, using an adaptive multichannel Wiener filter, we construct an estimate of the artifact signal, which subsequently can be subtracted from the noisy human ECG signal. The success of the proposed method is demonstrated through graphic examples, SNR, and rhythm classification evaluations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S O Aase, T Eftestøl, J H Husøy, K Sunde, P A Steen. 2000. CPR artifact removal from human ECG using optimal multichannel filtering.. https://doi.org/10.1109/10.880095

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗