PubMed Health⌕ Search

PubMed · 11088133

Density waves in traffic flow.

Abstract

Density waves are investigated in the car-following model analytically and numerically. This work is a continuation of our previous investigation of traffic flow in the metastable and unstable regions [Phys. Rev. E 58, 4271 (1998); 60, 180 (1999)]. The Burgers equation is derived for the density wave in the stable region of traffic flow by the use of nonlinear analysis. It is shown, numerically, that the triangular shock wave appears as the density wave at the late stage in the stable region. The decay rate of the shock wave is calculated and compared with the analytical result. It is shown that the density waves out of the coexisting curve, near the spinodal line, and within the spinodal line appear, respectively, as the triangular shock wave, the soliton, and the kink-antikink wave. The density waves are described, respectively, by the Burgers, Korteweg-de Vries, and modified Korteweg-de Vries equations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Nagatani. 2000. Density waves in traffic flow.. https://doi.org/10.1103/physreve.61.3564

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Monte Carlo estimation of the number of possible protein folds: effects of sampling bias and folds distributions.

The estimation of the number of protein folds in nature is a matter of considerable interest. In this study, a Monte Carlo method employing the broken stick model is used to assign a given number of proteins into a given number of folds. Subsequently, random, integer, non-repeating numbers are generated in order to simulate the process of fold discovery. With this conceptual framework at hand, the effects of two factors upon the fold identification process were investigated: (1) the nature of folds distributions and (2) preferential sampling bias of previously identified folds. Depending on the type of distribution, dividing 100,000 proteins into 1,000 folds resulted in 10-30% of the folds having 10 proteins or less per fold, approximately 10% of the folds having 10-20 proteins per fold, 31-45% having 20-100 proteins per fold, and >30% of the folds having more than 100 proteins per fold. After randomly sampling one tenth of the proteins, 68-96% of the folds were identified. These percentages depend both on folds distribution and biased/non-biased sampling. Only upon increasing the sampling bias for previously identified folds to 1,000, did the model result in a reduction of the number of proteins identified by an order of magnitude (approximately 9%). Thus, assuming the structures of one tenth of the population of proteins in nature have been solved, the results of the Monte Carlo simulation are more consistent with recent lower estimates of the number of folds, <or=1,000. Any deviation from this estimate would reflect significant bias in the experimental sampling of protein structure, and/or substantially nonuniform folds distribution, manifested in a large number of single-fold proteins.

Models, Theoretical↗

Lever-assisted two-noise stochastic resonance.

A critical interplay of two correlated noises in a nonlinear symmetrical two-well potential system is experimentally demonstrated. One state can become completely noise free, leading to an infinite Kramers time. If an independent lever breaks the potential symmetry, stochastic resonance is recovered. In this new regime, we obtain a plateau, i.e., a high signal-to-noise ratio even for vanishing forcing signals.

Models, Theoretical↗

High-speed path-length scanning with a multiple-pass cavity delay line.

Techniques for high-speed delay scanning are important for low-coherence interferometry, optical coherence tomography, pump probe measurements, and other applications. We demonstrate a novel scanning delay line using a multiple-pass cavity. Differential delays are accumulated with each pass so that millimeter delays can be generated with tens of micrometer mirror displacements. With special design criteria, misalignment sensitivity can be dramatically reduced. The system is demonstrated to scan 6 m/s at 2-kHz repetition rates. Real-time optical coherence tomography imaging with 500 pixel images at four frames/s is performed. Using a Cr:forsterite laser source, we obtained axial image resolutions of 6 microm with 92-dB sensitivity.

Models, Theoretical↗