PubMed Health⌕ Search

PubMed · 11094809

Dipole location errors in electroencephalogram source analysis due to volume conductor model errors.

Abstract

An examination is made of dipole location errors in electroencephalogram (EEG) source analysis, due to not incorporating the ventricular system (VS), omitting a hole in the skull and underestimating skull conductivity. The simulations are performed for a large number of test dipoles in 3D using the finite difference method. The maximum dipole location error encountered, utilising 27 and 53 electrodes is 7.6 mm and 6.1 mm, respectively when omitting the VS, 5.6 mm and 5.2 mm, respectively when neglecting the hole in the skull, and 33.4 mm and 28.0 mm, respectively when underestimating skull conductivity. The largest location errors due to neglecting the VS can be found in the vicinity of the VS. The largest location errors due to omitting a hole can be found in the vicinity of the hole. At these positions the fitted dipoles are found close to the hole. When skull conductivity is underestimated, the dipole is fitted close to the skull-brain border in a radial direction for all test dipoles. It was found that the location errors due to underestimating skull conductivity are typically higher than those found due to neglecting the VS or neglecting a hole in the skull.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Vanrumste, G Van Hoey, R Van de Walle, M D'Havé, I Lemahieu, P Boon. 2000. Dipole location errors in electroencephalogram source analysis due to volume conductor model errors.. https://doi.org/10.1007/bf02345748

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modulating ion channel properties of transmembrane peptide nanotubes through heteromeric supramolecular assemblies.

A selective heteromeric supramolecular assembly process is devised to create functional single channels of altered ion conductance, charge selectivity, and rectification. The hollow transmembrane tubular structure produced spontaneously from the self-assembly of cyclic-d,l-alpha-peptides in lipid bilayers is modified by designer cyclic peptide "cap" subunits that bind site-selectively at the mouth of the channel assembly.

Electric Conductivity↗

Incomplete inactivation of voltage-dependent K+ channels in human B lymphoma cells.

The voltage-dependent K (KV) channel in Daudi human B lymphoma cells was characterized by using patch-clamp techniques. Whole-cell voltage-clamp experiments demonstrated that cell membrane depolarization induced a transient (time-dependent) outward current followed by a steady-state (time-independent) component. The time-dependent current resembled behavior of the type n channel, such as use dependence and a unique blockade by tetraethylammonium (TEA). Both time-dependent and time-independent currents were blocked by quinine with a similar IC50 (14.2 mM and 12.6 mM). Treatment with antisense oligonucleotide of human Kv1.3 gene significantly reduced both currents by 80%. Single-channel experiments showed that only one type of KV channel was recorded with a unitary conductance of approximately 19 pS. Consistent with whole-cell recordings, the channel activity in cell-attached patches remained in response to prolonged depolarization, and the remaining channel activity was blocked by quinine, but not TEA. Channel activity was scarcely seen in cell-attached patches after antisense treatment. Whole-cell current-clamp data showed that TEA, which blocks only the time-dependent current, caused a slight decrease in the membrane potential. In contrast, quinine and antisense, which block both time-dependent and -independent currents, strongly reduced the membrane potential. These data together suggest that the KV channel in Daudi cells does not completely inactivate and that the remaining channel activity due to this incomplete inactivation appears to be primarily responsible for maintaining the membrane potential.

Electric Conductivity↗

Determination of electroosmotic flow mobility with a pressure-mediated dual-ion technique for capillary electrophoresis with conductivity detection using organic solvents.

A method is described for the indirect determination of the mobility of the electroosmotic flow (EOF), which can be carried out within a few minutes even for very low mobilities. It is independent of the direction of the EOF. It is based on the comparison of the measured mobilities of two oppositely charged reference ions (tetraphenylphosphonium and tetraphenylborate) with given mobilities in different organic solvents (methanol, acetonitrile, N,N-dimethylformamide, N,N-dimethylacetamide, propylene carbonate) at ionic strengths between 5 and 50 mM. The method is based on the sequential movement of the reference ions in a three-step process: first by a laminar flow to a certain position in the separation capillary, followed by electromigration due to application of voltage, and pressurised migration towards the detector. In this way the total mobilities of the reference ions can be determined from their residence times, and the difference to their known actual mobilities gives the mobility of the EOF. The method avoids misinterpretations caused by system- and eigen-peaks, which often bias the results especially when a conductivity detector is used. The method is suitable for all solvents, and is an advantage especially for organic and mixed aqueous-organic background electrolytes with high UV absorbance.

Electric Conductivity↗