Adaptive vector quantisation for electrocardiogram signal compression using overlapped and linearly shifted codevectors.

Abstract

A discrete semi-periodic signal can be described as x(n) = x(n + T + delta T) + delta x, [symbol: see text] n, where T is the fundamental period, delta T represents a random period variation, and delta x is an amplitude variation. Discrete ECG signals are treated as semi-periodic, where T and delta x are associated with the heart beat rate and the baseline drift, respectively. These two factors cause coding inefficiency for ECG signal compression using vector quantisation (VQ). First, the periodic characteristic of ECG signals creates data redundancy among codevectors in a traditional two-dimensional codebook. Secondly, the fixed codevectors in traditional VQ result in low adaptability to signal variations. To solve these two problems simultaneously, an adaptive VQ (AVQ) scheme is proposed, based on a one-dimensional (1D) codebook structure, where codevectors are overlapped and linearly shifted. To further enhance the coding performance, the delta x term is extracted and encoded separately, before 1D-AVQ is applied. The data in the first 3 min of all 48 ECG records from the MIT/BIH arrhythmic database are used as the test signals, and no codebook training is carried out in advance. The compressed data rate is 265.2 +/- 92.3 bits s-1 at 10.0 +/- 4.1% PRD. No codebook storage or transmission is required. Only a very small codebook storage space is needed temporarily during the coding process. In addition, the linearly shifted nature of codevectors makes this easier to be hardware implemented than any existing AVQ method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S G Miaou, J H Larn. 2000. Adaptive vector quantisation for electrocardiogram signal compression using overlapped and linearly shifted codevectors.. https://doi.org/10.1007/bf02345751

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of ventricular premature stimulus coupling interval on blood pressure and heart rate turbulence.

BACKGROUND: Heart rate turbulence (HRT) is a promising noninvasive risk stratifier for mortality after myocardial infarction. On the basis of a study of ventricular premature complex coupling interval and sympathetic nerve burst amplitude, we hypothesized that measures of HRT would increase with increased prematurity of the coupling interval. METHODS AND RESULTS: Twenty-eight patients undergoing programmed electrical stimulation were studied (12 with prior myocardial infarction, aged 60+/-18 years). An extrastimulus was delivered from the right ventricular apex after 20 sinus beats with a V-S(2) coupling interval decremented by 20 to 30 ms until refractoriness was reached. Turbulence slope (TS), turbulence timing (TT), and turbulence onset were calculated for each extrastimulus, and the linear regressions of these parameters on coupling interval and compensatory pause were calculated. Arterial blood pressure was measured with arterial catheter or a noninvasive continuous blood pressure transducer (Buffington cuff). TS and turbulence onset were abnormal in 4 and 13 patients, respectively. HRT parameters were significantly correlated with coupling interval or compensatory pause in only 2 or 3 patients for a given regression analysis. This absence of correlation was found likely to be due to lack of correlation between compensatory pause and systolic blood pressure after the compensatory pause. Heart rate and TS were correlated: Patients with high heart rate had low TS and late TT (TS=-2.7+0.01xsinus cycle length, P=0.018; TT=8.8 to 0.005xsinus cycle length, P=0.013). CONCLUSIONS: HRT can be induced by programmed stimulation. In this setting, heart rate affects HRT but not ventricular premature complex prematurity. Induced HRT seems to be a valid method for measuring HRT parameters in patients with few ventricular premature complexes.

Arrhythmias, Cardiac↗

Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay.

OBJECTIVES: We sought to compare the short- and long-term clinical effects of atrial synchronous pre-excitation of one (univentricular) or both ventricles (biventricular), that provide cardiac resynchronization therapy (CRT). BACKGROUND: In patients with heart failure (HF) who have a ventricular conduction delay, CRT improves systolic hemodynamic function. The clinical benefit of CRT is still being investigated. METHODS: Forty-one patients were randomized to four weeks of first treatment with biventricular or univentricular stimulation, followed by four weeks without treatment, and then four weeks of a second treatment with the opposite stimulation. The best CRT stimulation was continued for nine months. Cardiac resynchronization therapy was optimized by hemodynamic testing at implantation. The primary end points were exercise capacity measures. Data were analyzed by two-way repeated-measures analysis of variance. RESULTS: The left ventricle was selected for univentricular pacing in 36 patients. The clinical effects of univentricular and biventricular CRT were not significantly different. The results of each method were pooled to assess sequential treatment effects. Oxygen uptake during bicycle exercise increased from 9.48 to 10.4 ml/kg/min at the anaerobic threshold (p = 0.03) and from 12.5 to 14.3 ml/kg/min at peak exercise (p < 0.001) with the first treatment, and from 10.0 to 10.7 ml/kg/min at the anaerobic threshold (p = 0.2) and from 13.4 to 15.2 ml/kg/min at peak exercise (p = 0.002) with the second treatment. The 6-min walk distance increased from 342 m at baseline to 386 m after the first treatment (p < 0.001) and to 416 m after the second treatment (p = 0.03). All improvements persisted after 12 months of therapy. CONCLUSIONS: Cardiac resynchronization therapy produces a long-term improvement in the clinical symptoms of patients with HF who have a ventricular conduction delay. The differences between optimized biventricular and univentricular therapy appear to be small for short-term treatment.

Arrhythmias, Cardiac↗